R&S®SGS100A SGMA RF Source

Compact – fast – reliable

Key Facts

  • Smallest fully integrated vector signal generator on the market, space-saving design for system integration
  • Enables high throughput due to very short frequency and level setting times of typ. 280 μs via PCIe interface
Down to Key Facts

Brief Description

The R&S®SGS100A is an RF source designed to meet the requirements of automated test systems. It is available as a CW source or as a vector signal generator with an integrated I/Q modulator.

Specifications

R&S®SGS100A
Frequency range 1 MHz to 6/12.75 GHz
Level range -120 dBm to +15 dBm
Setting time <500 µs
Down to Specifications

Key Facts

  • Smallest fully integrated vector signal generator on the market, space-saving design for system integration
  • Enables high throughput due to very short frequency and level setting times of typ. 280 μs via PCIe interface
  • Excellent RF performance in a compact format
  • Maximum output level of typ. +22 dBm for compensating losses in the setup
  • Closed ALC loop for CW and I/Q modes for highest level repeatability
  • High output frequency up to 12.75 GHz for broad applicability
  • Wear-free electronic attenuator for high reliability
  • Very cost-efficient with low initial costs and low cost of ownership

Brief Description

The R&S®SGS100A is an RF source designed to meet the requirements of automated test systems. It is available as a CW source or as a vector signal generator with an integrated I/Q modulator. With its frequency range of up to 12.75 GHz, the vector signal generation version covers the essential digital signals. The CW version can be used as a flexible local oscillator as well as for interference testing against mobile radio standards.

Specifications

Frequency
Frequency range with the R&S®SGS-B106 option 1 MHz to 6 GHz
with the R&S®SGS-B106 and R&S®SGS-B112 options 1 MHz to 12.75 GHz
with the R&S®SGS-B106V option 80 MHz to 6 GHz (I/Q mode)
1 MHz to 6 GHz (CW mode)
with the R&S®SGS-B106V and R&S®SGS-B112V options 80 MHz to 12.75 GHz (I/Q mode)
1 MHz to 12.75 GHz (CW mode)
Setting time with PCIe remote control < 500 μs
Input frequency for external reference 10 MHz, 100 MHz, 1000 MHz
Level
Specified level range –10 dBm to +15 dBm (PEP) 1)
with the R&S®SGS-B26 option –120 dBm to +15 dBm (PEP) 1)
Level error Setting Characteristic: AUTO; temperature range from +18 °C to +33 °C
1 MHz ≤ f ≤ 3 GHz < 0.5 dB
3 GHz < f ≤ 12.75 GHz < 0.9 dB
Output impedance VSWR in 50 Ω system in full frequency range,
Setting Characteristic: AUTO
< 2.0
in full frequency range,
with the R&S®SGS-B26 option
< 1.8
Setting time with PCIe remote control,
Setting Characteristic: AUTO
< 500 μs
Spectral purity
Harmonics level ≤ 8 dBm, CW, I/Q wideband OFF < –30 dBc
Nonharmonics level > –10 dBm 2), offset > 10 kHz from carrier, f ≤ 1.5 GHz < –76 dBc
Subharmonics level > –10 dBm 2), f ≤ 3 GHz < –76 dBc
Wideband noise 1 MHz ≤ f ≤ 6 GHz and 10 MHz carrier offset, 6 GHz < f ≤ 12.75 GHz and 30 MHz carrier offset, AUTO mode, level > 5 dBm, 1 Hz measurement bandwidth, CW < –145 dBc
SSB phase noise 20 kHz carrier offset, 1 Hz measurement bandwidth
f = 1 GHz < –126 dBc, –130 dBc (typ.)
f = 10 GHz < –106 dBc, –110 dBc (typ.)
I/Q modulation
I/Q modulator bandwidth (RF) 100 MHz < f ≤ 2.5 GHz, I/Q wideband 40 % of carrier frequency
2.5 GHz < f ≤ 6 GHz, I/Q wideband 1 GHz
Error vector measured with 16QAM, filter root cosine α = 0.5, 10 kHz symbol rate
f > 80 MHz, RMS < (0.4 % + 0.2 % × f/GHz)
ACLR WCDMA 3GPP FDD, TM 1/64 > 67 dB, 69.5 dB (meas.)
Baseband bypass mode
Frequency range 1 MHz ≤ f ≤ 80 MHz
Specified level range –5 dBm to +15 dBm
with the R&S®SGS-B26 option –120 dBm to +15 dBm
Remote control using Rohde & Schwarz instrument driver PCIe (single lane)
using SCPI 1999.5 or compatible command sets Ethernet (TCP/IP) 10/100/1000BaseT
using SCPI 1999.5 or compatible command sets USB 2.0
General data
Power consumption 70 W (meas.)
Dimensions W × H × D 250 mm × 52.5 mm × 401 mm
(9.84 in × 2.07 in × 15.79 in)
1 HU, ½ 19" rack width
Weight when fully equipped 4.0 kg (8.82 lb)

1) PEP = peak envelope power.
2) > 0 dBm for instruments without the R&S®SGS-B26 electronic step attenuator.

Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Service Team

Feedback

Tell us your opinion
Please tell us which topic.
Please enter your inquiry.
Contact information

Please enter your first name.

Please enter a valid e-mail address.

Please enter your name.
Security Response Code
show captcha

The input was not correct.
*Mandatory Field
Configure your product

Contact Us
Request Information

Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Service Team

Please enter your inquiry.

Please enter your first name.

Please enter your name.

Please enter a valid e-mail address.

Please enter your company name.

Please enter your city name.

Please enter your postal code.

Please enter your country.
show captcha
The input was not correct.
*Mandatory Field
Request a Quote

Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Service Team

Please enter your inquiry.

Please enter your first name.

Please enter your name.

Please enter a valid e-mail address.

Please enter your phone number.

Please enter your company name.

Please enter your city name.

Please enter your postal code.

Please enter your country.
show captcha
The input was not correct.
*Mandatory Field
Request a Demo

Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Service Team

Please enter your inquiry.

Please enter your first name.

Please enter your name.

Please enter a valid e-mail address.

Please enter your company name.

Please enter your city name.

Please enter your postal code.

Please enter your country.
show captcha
The input was not correct.
*Mandatory Field

Downloads

Tools

Related Products
International Website