Ensure the integrity of the power grid
IEC 61000-3-2 harmonics testing and IEC 61000-3-3 flicker measurement
Harmonics are currents or voltages with frequencies that are integer multiples of the mains fundamental (typically 50/60 Hz). They occur when a load is non-linear - which is often the case for switch-mode power supplies (SMPS) - and can lead to a variety of power quality issues. This is why harmonic analysis is important: it identifies which harmonics are present, how large they are and how they evolve across operating states. These details determine both the root cause of the harmonics and the risk to the main.
Flicker refers to short-term fluctuations of voltage and current. It often means that a device has rapid changes in its power draw. While harmonics describe the distortion in a periodic waveform, flicker is more about the time variation in the load’s demand on the main. Flicker is important because both the main and connected equipment assume a stable power supply. If a device repeatedly causes quick voltage dips or rapid load changes, it can disturb other devices on the same grid.
The primary purpose of harmonics and flicker testing is to ensure that a device does not compromise the integrity of the power grid, rather than to demonstrate that the device performs its intended function. A device can “work fine” and still interact poorly with the surrounding ecosystem.
Harmonics and flicker compliance testing is typically performed in a controlled environment with a stabilized AC source and calibrated measurement tools.
Common reasons products fail compliance testing include:
- Non-linear current draw: Switch-mode power supplies draw current in short bursts, which can lead to harmonic distortion. This can be avoided with input filtering or passive correction.
- Under-corrected PFC behavior: High-power devices (above 75 W) should include power factor correction (PFC). Poorly implemented PFC can lead to emissions past the acceptable range by introducing low-order harmonics and increasing the crest factor.
- Inrush current at start-up: Short-duration current spikes can occur when a device is powered on. These spikes can exceed harmonic current limits, even when the steady state is acceptable.
- Power-state transitions: Embedded systems often change operating states. These transitions can cause harmonics or flicker.
Power analyzers and oscilloscopes can reveal undesirable harmonics and flicker. Power analyzers have a harmonics mode that performs a fast Fourier transform (FFT) to calculate the root mean square (RMS) value and phase angle. Certain power analyzers, such as the LMG from ZES Zimmer, can do this for up to the first 200 harmonics. Current harmonics are most commonly measured using an oscilloscope and appropriate probes. The results are typically presented in both graphical and numerical format. In some cases, a scope may also support an automatic test for verifying compliance to one or more harmonic standards. During validation and compliance stages, power analyzers are used to generate reports and help identify which harmonics are violating the maximum limits given in the standards.