Specifications
R&S®ADD119 (In combination with R&S®DDF0xA and R&S®DDF0xE) |
|
Application |
mobile, for ground waves and sky waves with low elevation angle |
Frequency range |
(0.3 MHz) 1 MHz to 30 MHz, below 1 MHz with limited sensitivity and accuracy |
Antenna type |
1 crossed loop and 1 active dipole |
DF method |
Watson-Watt |
Polarization |
vertical |
DF accuracy1) |
2°RMS |
Sensitivity |
typ. 4 µV/m to 2.5 µV/m (2° bearing fluctuation, 250 Hz bandwidth, 1 s averaging time) |
Power supply |
from DF equipment |
Dimensions (approx.) |
1100 mm diameter × 232 mm height |
Color |
RAL 1015 |
Weight (approx.) |
25 kg |
1) Measurement in reflection-free environment. The RMS error is calculated from the bearings of an evenly distributed azimuth and frequency sample.
R&S®ADD119 (In combination with R&S®DDF®195 and R&S®DDF255) |
|
Application |
mobile, fast scanning for ground waves and sky waves with low elevation angle |
Frequency range |
(0.3 MHz) 1 MHz to 30 MHz, below 1 MHz with limited sensitivity and accuracy |
Antenna type |
1 crossed loop and 1 active dipole |
DF method |
Watson-Watt |
Polarization |
vertical |
DF accuracy1) |
2°RMS |
Sensitivity |
typ. 10 µV/m to 4 µV/m (5° bearing fluctuation, 250 Hz bandwidth, 5 s averaging time) |
Power supply |
from DF equipment |
Dimensions (approx.) |
1100 mm diameter × 232 mm height |
Color |
RAL 1015 |
Weight (approx.) |
25 kg |
1) Measurement in reflection-free environment. The RMS error is calculated from the bearings of an evenly distributed azimuth and frequency sample