382 Results
I want to export the waveform data of my RTO scope into MATLAB, but the only way I found so far is the screenshot option. Is there another way to use the trace data in my script?
R&S RTO/R&S RTP USB 2.0/3.2 Compliance Test User Manual. The user manual describes the USB 2.0 compliance test procedures.
Rohde & Schwarz "Getting Started" for R&S RTO digital oscilloscopes.
Instrument Security Procedures for R&S® RTO2000
Advanced Signal Analysis using the History Mode of the R&S RTO Oscilloscope.
03-Jun-2013 | AN-No. 1TD02
Rohde & Schwarz user manual for the R&S RTO digital oscilloscopes including options R&S RTO-K1, K2, K3, K4, K5, K6, K7, K8, K9, K10, K11, K12/13, K17, K31, K40, K50, K52, K55, K60, K65, B1
Programming examples for oscilloscopes.
This application note explains how to measure the oscilloscope ENOB and shows results for the R&S®RTO for different settings.
13-May-2011 | AN-No. 1ER03
01-Jul-2021
New R&S RTO6 oscilloscopes from Rohde & Schwarz deliver instant insights thanks to enhanced usability and performanceRohde & Schwarz takes its successful R&S RTO family to the next level with the all-new and redesigned R&S RTO6 oscilloscope. Featuring an updated user interface on a larger, 15.6-inch Full HD touchscreen and straightforward workflows, it speeds up daily measurement tasks. The R&S RTO6 delivers deep insights into designs on the engineer's workbench with state-of-the-art specifications such as an outstanding 9.4 ENOB, an unparalleled update rate of one million waveforms per second as well as a comprehensive toolset of analysis functions.
The Zoom function does not show any waveform data at specific settings, especially at slower timebases in combination with higher sample rates, High resolution and roll mode with more channels. The problem is gone if a lower sample rate is chosen.
The R&S®RTO oscilloscope is a valuable tool for analyzing EMI problems in electronic designs.
27-Jun-2018
Equipped with the R&S®RTO-K11 I/Q software interface option, the R&S®RTO provides the I/Q data of the acquired signals to the external R&S®FS-K10xPC LTE analysis software for demodulation and detailed analysis. video, LTE, MIMO, FS-K10xPC, RTO, RTO-K11 Rohde & Schwarz at EuMW 2012: Up to 4 LTE MIMO antenna signal analysis with one oscilloscope
Testing LTE MIMO Signals using a R&S RTO Oscilloscope
24-Apr-2013 | AN-No. 1EF86
This document describes the use of the R&S®RTO and R&S®RTP to demodulate RF pulses for further measurements and precisely trigger on and analyze RF pulses.
13-Mar-2019
The R&S®RTP/R&S®RTO and R&S®VSE meet the need to verify 5G NR MIMO signals and the signal characteristics of beamforming quickly and coherent.
04-Mar-2020
The R&S®RTO and R&S®RTP oscilloscopes are capable of triggering precisely on a pulse as a prerequisite for time domain and frequency domain analysis.
13-Mar-2019
LTE beamforming can be accurately tested with one or more R&S®RTO digital oscilloscopes for a 1×2, 1×4 or even a 1×8 MIMO system.
16-Aug-2016
R&S®ScopeSuite Compliance testing of a USB 2.0 device with the R&S®RTO. Test automation with the R&S®RTO-K21 option (R&S®ScopeSuite) Compliance testing of a USB 2.0 device with the R&S®RTO. Test automation with the R&S®RTO-K21 option (R&S®ScopeSuite) USB, Compliance testing, compliance measurements USB 2.0 compliance testing - R&S®ScopeSuite
Rohde & Schwarz user manual for the R&S RTO2000 oscilloscopes including options R&S RTO-K1, K2, K3, K4, K5, K6, K7, K8, K9, K10, K11, K12/13, K18, K19, K31, K40, K42, K44, K50, K52, K55, K57, K60, K61, K63, K64, K65, K72, K76, K91, K121,K133, B1, B6, B7
Automated measurement functions in combination with track functionality make it easier to analyze single events and reveal “long-term” variations.
29-Nov-2018
Discover how to easily decode Flexray using an R&S®RTO. Discover how to easily decode Flexray using an R&S®RTO. RTO2000, decoding, flexray, automotive Discover how to easily decode Flexray using an R&S®RTO.
Discover how to debug CAN interfaces, as displayed on an R&S®RTO. Discover how to debug CAN interfaces, as displayed on an R&S®RTO. RTO2000, debugging, CAN interfaces, automotive Discover how to debug CAN interfaces, as displayed on an R&S®RTO.
Video, RTO2000, Oscilloscope, 2 Gsample deep memory The R&S®RTO oscilloscopes' acquisition memory can be extended up to 2 Gsample.
Signal faults, waveforms/s, RTO2000, ASIC R&S®RTO oscilloscopes display up to 1 million waveforms/s. To make this possible, Rohde & Schwarz developed an ASIC with optimized signal processing. R&S®RTO oscilloscopes enable you to quickly and reliably detect sporadic signal faults.
Flat frequency, RTO2000, accurate measurements The flat frequency response ensures accurate signal acquisition over the R&S®RTO oscilloscope's entire specified bandwidth.
RTO-K21 USB2.0 Compliance Test for R&S® RTO digital oscilloscopes
Discover the powerful decoding capability of Rohde and Schwarz oscilloscopes, as displayed on an R&S®RTO Discover the powerful decoding capability of Rohde and Schwarz oscilloscopes, as displayed on an R&S®RTO RTO2000, serial bus decoding, oscilloscope, automotive Discover the powerful decoding capability of Rohde and Schwarz oscilloscopes, as displayed on an R&S®RTO.
Discover how to debug CAN-FD, as displayed on an R&S®RTO. Discover how to debug CAN-FD, as displayed on an R&S®RTO. RTO2000, debugging, CAN-FD, flexible data, automotive Discover how to debug CAN-FD, as displayed on an R&S®RTO.
Guideline for 100Base-T1 compliance testing using the R&S®RTO and R&S®ZND. Guideline for 100Base-T1 compliance testing using the R&S®RTO and R&S®ZND. Video, RTO2000, ZND, 100Base-T1 Guideline for 100Base-T1 compliance testing using the R&S®RTO and R&S®ZND.