Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
853 Results
R&S®SITLine ETH-XL is a BSI-approved layer 2 Ethernet encryptor for 1 x 100 Gbps or 2 x 100 Gbps lines.
ZN-Z1xx (ZN-Z170, ZN-Z135, ZN-Z129, ZN-Z129E up to 43.5 GHz) Economy Vector Network Analzer Calibration Kits, 4-in-1 design: open, short, match , through combined in a compact unit. Seperate male and female models.
Crossed log-periodic antenna – for reception of waves with linear or circular polarization in the frequency range from 1 GHz to 18 GHz
30-May-2023 | Press Release | Wireless communications
Rohde & Schwarz and IEMN collaborate on 6G THz by bringing together electronic and photonic technologiesThe Institute of Electronics, Microelectronics and Nanotechnology (IEMN, Lille, France) and Rohde & Schwarz have expanded their collaboration to research THz communications that utilize photonic technologies. In a recent demonstration, IEMN reached a milestone when researchers achieved generated a 300 GHz bidirectional link over an outdoor distance of 645 m for use in future 6G backhauling scenarios. The R&S SMA100B microwave signal generator from Rohde & Schwarz was a crucial component in the performance test setup. The R&S SMA100B provides an ultra-low phase noise signal that helps accelerate THz communications research and development to ready it for industrialization.
05-Sep-2023 | Press Release | Wireless communications
Rohde & Schwarz and Greenerwave collaborate to verify RIS modules and drive 6G researchReconfigurable intelligent surfaces (RIS) can revolutionize wireless communication performance for 5G and future 6G applications. A groundbreaking measurement campaign by Rohde & Schwarz and Greenerwave confirms the capabilities of a novel FR2 RIS module, improving coverage and efficiency.
The two-quadrant R&S®NGU201 and the four-quadrant R&S®NGU401 provide up to 60 W of power and measurements with up to 6 ½ digits resolution.
The R&S®NGA100 power supplies are linear, compact and easy to use. All models have excellent readback accuracy with a low-current range for demanding measurements.
They can operate in all four quadrants and are referred to as source measure units (SMUs) . In the first and third quadrant, current flows out of the voltage terminal; the instrument is sourcing power. In the second and fourth quadrant, current flows into the voltage terminal; the instrument is sinking power.
Serial protocols are used in a very wide variety of applications. Learn more about different serial protocols and how to decode them using an oscilloscope.
Get an introduction into RF and read about the three general uses of radio frequency technologies: transfer information and heating & sensing objects.
The R&S®NRPxxS/SN/SN-V three-path diode power sensor delivers highly accurate power measurement results independent of the modulation type.
The software defined, multiband-capable airborne transceivers in R&S®M3AR family with modular design and state-of-the-art technology.
The modular R&S®OSP can quickly and easily perform RF switching and controlling. Electromechanical RF relays, SSR and digital I/O modules are available.
Automatic multichannel detection, classification, demodulation and decoding of communications signals.
The universal reference receiver for digital and analog TV and radio. Provides high measurement precision and extensive measurement functions.
R&S®ZVA110 vector network analyzer - high performance up to 110 GHz
Signal analyzer module with eight-channel waveform analyzer for R&S CompactTSVP test system versatile platform.
TS-PFG, function Generator module, arbitrary waveform, TSVP, marker Signal, waveform Generator, LF-generato
Passive receiving dipole – monitoring antenna for vertical polarization in the frequency range from 20 MHz to 1.3 GHz for stationary and mobile use.
Server-Based Testing is designed for repetitive + automated environments in a scenario such as 5G macrocell base station production testing.
Fully automatic radiated spurious emission measurements on wireless communications equipment for R&D and quality assurance
R&S®CLIPSTER mastering system provides a powerful way to edit any type of media and create professional deliverables like IMF and DCP.
31-Jan-2024 | Press Release | Wireless communications
Rohde & Schwarz and VIAVI jointly verify NEC O-RU design at O-RAN Global PlugFest Fall 2023 in JapanAt the recent O-RAN ALLIANCE Global PlugFest Fall 2023 at the Japan Open Testing and Integration Center (OTIC) hosted by Rakuten Mobile, Rohde & Schwarz and VIAVI Solutions have presented their integrated solution for automated conformance testing of O-RAN Radio Units (O-RUs). With their joint test solution, which combines both companies’ industry-leading capabilities, they performed the automated verification of a commercial O-RU provided by NEC according to both O-RAN and 3GPP pre-conformance specifications.
VHF/UHF stationary radio family for military ATC, AD and shipborne communications
Broadband impedance matching unit for test receivers and spectrum analyzers with low-impedance inputs.
21-Dec-2023 | Press Release | Wireless communications
Rohde & Schwarz and VIAVI jointly verify Analog Devices’ leading O-RU reference design at i14y Lab PlugFest Fall 2023Rohde & Schwarz and VIAVI Solutions have presented their integrated solution for conformance testing of O-RAN Radio Units at the recent O-RAN ALLIANCE Global PlugFest Fall 2023, hosted at the i14y Lab in Berlin – supported by Deutsche Telekom and EANTC and i14y consortium partners.
07-Nov-2023 | Press Release | Test & measurement
When innovation meets production – Rohde & Schwarz exhibits at productronica 2023Innovation and production – hand in hand. The Rohde & Schwarz motto for this year’s productronica, where the company will present itself as a reliable partner for electronics manufacturing needs. Visit us at booth A1/375.
Using the ZN-Z103 calibration unit with the FPC1500
ZNB/ZND - wrong connector type shown at Cal Unit Characterization