R&S®NRP-Z86 model .44 Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
- Visão geral
- Options
- Features & Benefits
-
Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 44 GHz,
2.4 mm connector
-
Two-Path diode power sensors
Cost-effective power measurement solution for production
Universal power sensor, 10 MHz to 8 GHz, 100 mW, two-path
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 8 GHz,
N connector -
Two-Path Diode Power Sensors
Cost-effective power measurement solution for production
Universal power sensor, 10 MHz to 18 GHz, 100 mW, two-path
Measurement range: -60 dBm to +20 dBm,
Frequency range: 10 MHz to 18 GHz,
N connector
-
Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 18 GHz,
N connector -
Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.92 mm connector -
Wideband Power Sensor
Time domain analysis and automatic pulse analysis for radar applications and universal use
Time domain analysis and automatic pulse analysis for radar applications and universal use
Measurement range: -60 dBm to +20 dBm,
Frequency range: 50 MHz to 40 GHz,
2.4 mm connector
-
Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 18 GHz,
N connector -
Power Sensor Module (for use with R&S®FSMR)
Level calibration of signal sources in conjunction with the R&S®FSMR measurement receiver
Measurement range: -24 dBm to +26 dBm,
Frequency range: DC to 26.5 GHz,
3.5 mm connector
-
R&S®NRP-Z2 Nº da encomenda 1146.6750.03 / 1146.6750.05 / 1146.6750.10 / 1146.6750.15Sensor Extension Cable
In some cases the signal source is far away from the base unit. Therefore four different sensor extension cables are available, to get a total length of 3, 5 or 10 meters.
-
R&S®NRP-Z3 Nº da encomenda 1146.7005.02USB Adapter (active)
R&S®NRP-Z3 active USB adapter has been developed for applications requiring external triggering of the power sensor. It also offers a separate power supply.
-
R&S®NRP-Z4 Nº da encomenda 1146.8001.02 / 1146.8001.04 / 1146.8001.06 / 1146.8001.11USB Adapter (passive)
For all R&S®NRP-Z sensors. The R&S®NRP-Z4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lengths: Available cable lengths: 2.0m, 0.5m and 0.15m Available cable length for panel-mount: 1m
For all R&S®NRP-Z sensors. The R&S®NRPZ4 passive USB adapter provides all basic functions, as it handles the transmission of settings and measurement data as well as the power supply of the sensor via the USB bus. Available cable lengths: Available cable lengths: 2.0m, 0.5m and 0.15m Available cable length for panel-mount: 1m
-
USB sensor hub
R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.