R&S®NRPM OTA power measurement solution

R&S®NRPM OTA power measurement solution
Abrir o Lightbox
R&S®OTA power measurement solution, RF shield box
Abrir o Lightbox
R&S®NRPM-A90 single-polarized antenna module
Abrir o Lightbox
R&S®NRPM-A90D dual-polarized antenna module
Abrir o Lightbox
R&S®NRPM3 3-channel sensor module
Abrir o Lightbox
R&S®NRPM-Z3 interface module
Abrir o Lightbox
R&S®NRPM-ZD3 filtered feedthrough module
Abrir o Lightbox
R&S®NRPM OTA power measurement solution R&S®OTA power measurement solution, RF shield box R&S®NRPM-A90 single-polarized antenna module R&S®NRPM-A90D dual-polarized antenna module R&S®NRPM3 3-channel sensor module R&S®NRPM-Z3 interface module R&S®NRPM-ZD3 filtered feedthrough module

Key facts

  • Frequency range from 18 GHz to 90 GHz
  • Ideal for beamforming tests
  • For 5G, WLAN IEEE 802.11ad and IEEE 802.11ay
  • Fully calibrated antenna module with integrated diode detector
  • Scalable to customer requirements
  • 3 years warranty extension

Designed for extremly accurate Over-the-Air (OTA) power measurements

The R&S®NRPM is a fully calibrated and individual scalable OTA power measurement solution for benchtop application or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz it is perfect for Over-the-Air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of the transmit antenna output power.

Features & benefits

Specified system uncertainty

Fully calibrated OTA power measurement system with specified system uncertainty

With conventional OTA systems, measurement uncertainty comes from frequency-dependent antenna gain and antenna pattern and from mismatched RF components. By measuring power directly at the antenna, the R&S®NRPM solution avoids this problem because it does not need any additional RF components. Moreover, the antenna gain, the antenna pattern and the diode detector are calibrated together. Complicated system calibration by the user is not necessary.

Open Lightbox

OTA power measurement system

Low-reflection antenna module

Low radar cross section to avoid disturbing reflections

The R&S®NRPM-A90 and -A90D antenna modules have a very low radar cross section of typically < –26 dB/sm, putting them about 15 dB/sm below the value of a typical horn antenna. This makes them ideally suited for use in a screened environment, due to the virtual absence of reflections.

Open Lightbox

R&S®NRPM-A90 low-reflection antenna module

Very high sensitivity

R&S®NRPM OTA power measurement solution therefore uses a highly sensitive diode detector which is integrated directly on the antenna

The R&S®NRPM-A90 and R&S®NRPM-A90D antenna modules are therefore able to measure power down to -76 dBm. For example, a DUT with a transmit power of -10 dBm can be positioned at a distance of 1 m, and  the received power at the antenna module can still be determined precisely.

Open Lightbox

OTA power measurement solution, benchtop

System calibration for OTA receiver tests

To test the receiver of the DUT, it is necessary to know exactly the power at the DUT, transmitted OTA to the DUT. To calibrate this measurement setup, the R&S®NRPM-A90 antenna module is positioned at the DUT to calibrate the transmit power of the signal generator. The calibration is done with an R&S®NRPM-A90/A90D antenna module, which is then replaced by the DUT. The receive power of the DUT is then exactly known.

Open Lightbox

System calibration for OTA receiver tests

TX beamforming verification

Multiple R&S®NRPM-A90/A90D antenna modules are needed to test the beamforming function. If the antenna beam is directed at a specific antenna module, this module shows the highest power of all antennas. Three antenna modules – arranged in a plane – are used to verify whether beamsteering in the horizontal plane functions properly. To test vertical beamforming, the R&S®NRPM-A90/A90D antenna modules must be arranged in at least two horizontal planes.

Open Lightbox

TX beamforming verification

Specifications
R&S®NRPM-A90 single polarized antenna
Frequency range   18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
  trace -63 dBm to -19 dBm
Rise/fall time   2.2 μs
Video bandwidth   220 kHz
Measurement uncertainty
18 GHz to 24 GHz absolute 0.68 dB to 0.81 dB
  relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.49 dB to 0.66 dB
  relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.50 dB to 0.72 dB
  relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.58 dB to 0.83 dB
  relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.61 dB to 0.91 dB
  relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.69 dB to 0.97 dB
  relative 0.05 dB to 0.09 dB
R&S®NRPM-A90D dual polarized antenna
Frequency range   18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
  trace -63 dBm to -19 dBm
Rise/fall time   2.2 μs
Video bandwidth   220 kHz
Measurement uncertainty (measurement distance 1m)
18 GHz to 24 GHz absolute 0.73 dB to 0.85 dB
  relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.55 dB to 0.71 dB
  relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.59 dB to 0.78 dB
  relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.68 dB to 0.90 dB
  relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.72 dB to 0.99 dB
  relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.87 dB to 1.10 dB
  relative 0.05 dB to 0.09 dB

Available options

Antenna modules
Product
Description
R&S®NRPM- A90 single polarized antenna module

Order number 1426.7760.02

Description
Single-polarized antenna module
Fully calibrated, low-reflection, single-polarized Vivaldi antenna with an integrated diode detector for power measurements.
R&S®NRPM-A90D dual-polarized antenna module
R&S®NRPM-A90D

Order number 1426.7777.02

Description
Dual-polarized antenna module
Two low-reflection, single-polarized Vivaldi antennas with an integrated diode detector, precisely arranged in a right angle. This allows measurement in both polarization directions.
Sensor modules
Product
Description
NRPM3-Three-Channel_Sensor_Module_img1.jpg

Order number 1425.8563.02

Description
Three-channel sensor module
Interface for shielded RF test box
Product
Description
R&S NRPM-ZD3 filtered cable feedthrough
R&S®NRPM-ZD3

Order number 1425.8786.02

Description
Filtered cable feedthrough
R&S®NRPM-ZKD3 interface cable
R&S®NRPM-ZKD3

Order number 1425.8770.02

Description
Interface cable
Interface for benchtop application
Product
Description
R&S®NRPM-Z3 interface module
R&S®NRPM-Z3

Order number 1426.7602.02

Description
Interface module
The R&S®NRPM-Z3 is directly plugged onto the R&S®NRPM3 three-channel sensor module and can host up to three R&S®NRPM-A90 antenna modules to avoid additional cables.
General accessories
Product
Description
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.02

Description
USB interface cable, length: 0.75 m
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.03

Description
USB interface cable, length: 1.5 m
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.04

Description
USB interface cable, length: 3 m
NRP-ZKU USB interface cable
R&S®NRP-ZKU

Order number 1419.0658.05

Description
USB interface cable, length: 5 m
R&S®NRP-ZK6

Order number 1419.0664.02

Description
6-pole interface cable, length: 1.5 m
R&S®NRP-ZK6

Order number 1419.0664.03

Description
6-pole interface cable, length: 3 m
R&S®NRP-ZK6

Order number 1419.0664.04

Description
6-pole interface cable, length: 5 m
NRP-Z5_Sensor_Hub_front.jpg
R&S®NRP-Z5

Order number 1146.7740.02

Description
USB sensor hub
R&S®NRPM-ZKT

Order number 1425.8857.02

Description
Trigger cable

Related videos

Usar o R&S®NRPM

mai 18, 2020

Entender as medições de potência OTA

mai 18, 2020

Peça informações

Você tem alguma pergunta ou precisa de informação adicional? Simplesmente preencha este formulário e nós respondemos imediatamente.

Quero receber informações da Rohde & Schwarz por

Licença de marketing

O que isso significa?

Concordo que a ROHDE & SCHWARZ GmbH & Co. KG e a entidade ou subsidiária ROHDE & SCHWARZ que figuram na Informação Legal deste site podem entrar em contato comigo por meio do canal escolhido (e-mail ou correio) para fins de marketing e publicidade (por exemplo, informações sobre ofertas especiais e promoções de descontos) relacionados, mas não limitados, a produtos e soluções para teste e medição, comunicações seguras, monitoramento e testes de redes, broadcast e mídia, e segurança cibernética.

Seus direitos

Esta declaração de consentimento pode ser retirada a qualquer momento, enviando um e-mail com o assunto "Cancelar subscrição" para news@rohde-schwarz.com. Além disso, cada e-mail enviado tem um link para cancelar a subscrição de futuros anúncios por e-mail. Mais detalhes sobre a utilização de dados pessoais e o procedimento de rescisão estão definidos na “Declaração de privacidade”.

O seu pedido foi submetido. Iremos contactá-lo em breve.
An error is occurred, please try it again later.
Informações gerais e legais

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Termos e condições do sorteio de prêmios: 10 anos dos osciloscópios da Rohde & Schwarz

1. O sorteio de prêmios “10 anos dos osciloscópios da Rohde & Schwarz” (no presente, referido como “Sorteio”) é organizado pela Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munique, Alemanha, tel. +49 89 41 29 0 (doravante referida como “R&S”).

2. Todos os participantes podem se inscrever durante o período de 1º de janeiro de 2020 a 31 de dezembro de 2020, informando seu nome, nome da empresa e e-mail comercial.

3. A participação é gratuita e não depende da compra de mercadorias ou serviços.

4. O sorteio está aberto somente a pessoas jurídicas e apenas às pessoas jurídicas que possam ganhar os prêmios. Pessoas físicas não poderão participar em nome e interesse próprios, mas como representantes de uma pessoa jurídica, devendo preencher a ficha de participação em nome e segundo o interesse da pessoa jurídica.

5. Os prêmios a serem entregues são 1 de 10 R&S®RTB2000, no período de 1º de janeiro de 2020 a 31 de dezembro de 2020:

Prêmio: 1 osciloscópio digital R&S®RTB2000

6. O sorteio ocorrerá na sede da R&S, em Munique, à Muehldorstrasse 15, 81671. O ganhador dos prêmios será avisado por e-mail no prazo de cinco (5) dias úteis.

7. O representante autorizado da pessoa jurídica informará à R&S sobre a aceitação do preço. Caso a aceitação seja negada ou se não houver resposta em até duas (2) semanas, um novo ganhador será sorteado. Se não for possível definir um ganhador no prazo de quatro (4) semanas, o sorteio se encerrará e o prêmio prescreverá.

8. Aos funcionários da R&S e seus familiares, bem como às pessoas familiarizadas com o processo do sorteio e seus familiares, é vetado o preenchimento da ficha de participação.

9. Não são permitidos equivalente em dinheiro ou troca de prêmios. Os prêmios são intransferíveis. Todos os impostos, tributos, encargos, taxas e outras cobranças tributáveis no país do participante serão arcadas pelo participante.

10. Dados pessoais somente serão processados para os fins deste sorteio e excluídos quatro (4) semanas após o sorteio, se não acordado de outro modo.

11. O participante que não cumprir os presentes Termos e Condições estará sujeito à desclassificação pela R&S da participação neste concurso. Neste caso, os prêmios também poderão ser retirados retroativamente. Se um prêmio estiver sujeito à retirada retrospectiva por motivo de incumprimento dos presentes Termos e Condições, ele deverá ser devolvido pelo respectivo participante, às suas expensas, para o endereço da R&S mencionado na disposição N.1, e um novo ganhador será sorteado.

12. Os participantes não podem reivindicar os prêmios do sorteio e não são autorizados recursos legais neste sentido.

13. O sorteio e a relação contratual decorrente, entre a R&S e o respectivo participante, serão regidos e interpretados de acordo com as leis da Alemanha, sem dar efeito ao princípio do conflito de leis. Os tribunais de Munique, Alemanha, gozarão de jurisdição exclusiva em caso de disputa decorrente, direta ou indiretamente, da participação neste concurso.