Changing the update display rate of a sweep with many sweep points.
Calibrating a vector network analyzer (VNA) with different connectors on each port
Converting the real and imaginary numbers to magnitude in dB and phase in degrees.
R&S®ZVAX-TRM Instrument Security Manual
Sending a remote Control Command internally
What is the correct pin layout of the DC inputs on the network analyzer's rear panel?
R&S®ZVAX-TRM User Manual
I have set my VNA to single sweep mode and switched on averaging with a factor of 10. But when I restart the single sweep, it stops after 1 sweep and the averaging is not done.
Rohde & Schwarz Getting Started for the R&S ZCxxx frequency converters
I trigger this single sweep with the RSZVB_Send_Trigger_and_Wait_for_OPC driver, but this driver does not wait for the complete 10 sweeps. If I don't use averaging, this program is works.
I query the values of a trace using scpi commands. But I get the y-values only. Is there a possibility to get the y-values also (frequency)?
How can I switch from remote to local state via remote control?
TDR, TDT, ZVA vector network analyzer This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines
I have used my TRL calibration kit with my ZVA before. Now I want to use also with my ZNB. But when I try to load the data of the calibration kit into the ZNB, the above error message is shown.
How do I calculate these frequency points when I have a logarithmic sweep and know the center frequency, the span and the number of sweep points?
TDR, TDT, ZVA vector network analyzer, This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
TDR, TDT, ZVA vector network analyzer This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
TDR, TDT, ZVA vector network analyzer, This video series demonstrates the calibration of a four-port network analyzer and the measurement of rise time, impedance vs. distance and skew on a board with differential lines.
The R&S®ZVA vector network analyzer in combination with the R&S®ZVAB-K30 noise figure measurement option simplifies noise figure measurement, a key parameter for receiver performance evaluation.
ZVA Vector Network Analyzers, PIM, Rohde & Schwarz demonstrated fast and accurate passive intermodulation (PIM) testing of duplex filters at the European Microwave Week 2013 in Nuremberg.
Models: R&S®ZVA-Z90, R&S®ZVA-Z110, R&S®ZVA-Z110E, R&S®ZVA-Z110E
I want to use Port 1 and Port 3, so I tried to switch them on by setting the value to 1 (the default value) and to switch off Port 2 and Port 4 by setting the value to 0. But this does not work. How do I set the ports?
R&S®ZVA-Zxx Millimeterwave Converters - Specifications
Versatile Software Tool for Rohde & Schwarz Instruments
RSCommander is a versatile software tool for a wide range of Rohde & Schwarz spectrum-, network analyzers, signal generators and oscilloscopes. It allows for automatic instrument discovery, making screenshots, reading traces, file transfer and simple script creation.
24-Dec-2017 | AN-No. 1MA074
ZVA80_2Port
This application note aims to explain test procedures and characterization of the relevant parameters for active phased array antennas.
04-Jul-2016 | AN-No. 1MA248
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Apple iPad as if working on it locally.
28-Mar-2013 | AN-No. 1MA216
This document describes the unique application of Rohde & Schwarz VNA to fully characterize the passive part of multi-element antennas.
20-Mar-2017 | AN-No. 1MA278
R&S ZV-WRxx R&S®ZCWM-570 Waveguide Calibration Kits - Specifications