Amplifier type |
|
class A |
Frequency bands |
|
9 kHz to 250 MHz, instantaneously 4 KHz to 400 MHz 80 MHz to 1.0 GHz, instantaneously 0.69 GHz to 3.2 GHz, instantaneously 2.5 GHz to 6.0 GHz, instantaneously |
Nominal output power |
9 kHz to 250 MHz |
125 W to 2500 W |
|
4 kHz to 400 MHz |
75 W to 600 W |
|
80 MHz to 1.0 GHz |
70 W to 3000 W |
|
0.69 GHz to 3.2 GHz |
30 W to 800 W |
|
2.5 GHz to 6.0 GHz |
15 W to 400 W |
Nominal output load |
|
50 Ω |
Gain flatness |
|
±4.0 dB (or better, see data sheet) |
Gain adjustment range |
|
> 15 dB |
Modulation capability |
|
AM, FM, φM, PM |
Nominal input impedance |
|
50 Ω |
Max. RF input level |
|
max. +15 dBm |
|
9 kHz to 250 MHz |
max. +5dBm |
Input level for nominal output power |
|
–3.4 dBm |
Nominal output impedance |
|
50 Ω |
Output mismatch tolerance, VSWR |
|
100 %, without damage |
RF and sample connectors
|
RF input port |
|
N female |
RF output port |
|
N female or 7/16 DIN female or 1 5/8" EIA female |
RF sample ports |
forward output power, optional |
N female |
|
reflected output power, optional |
N female |
Detected sample ports |
forward output power, optional |
N female |
|
reflected output power, optional |
N female |
Graphical user interface
|
Local graphical display |
|
200 × 48 pixel, monochrome |
Web GUI |
via Ethernet |
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
Remote control
|
Ethernet |
|
RJ-45, 10/100 Mbit/s, autonegotiation, half/full duplex |
General data
|
Operating voltage range |
R&S®BBA150-A125 to -A200/-AB75 to -AB200/-BC70 to -BC250/-D30 to -D110/-E15 to -E100 |
100 V to 240 V AC ± 10 %, single phase, 50 Hz to 60 Hz ± 6 % |
|
R&S®BBA150-A400/-AB350/-D200/-E200 |
120 V to 240 V AC ± 10 %, single phase, 50 Hz to 60 Hz ± 6 % |
|
R&S®BBA150-A700/-AB600/-BC500/ -BC1000/-D400/-E400 |
200 V to 240 V AC ± 10 %, single phase, 50 Hz to 60 Hz ± 6 % |
|
R&S®BBA150-A1300/-A2500/-BC1250 to -BC3000/-D800 |
380 V to 415 V AC ± 10 %, three phase, with N, 50 Hz to 60 Hz ± 6 % |
Air cooling |
|
forced air, built-in fans, air entry at front, air exit at rear |
Dimensions |
Desktop model |
incl. fans, handles and feet; W × H × D |
430 mm × 196 mm × 580 mm (16.93 in × 7.72 in × 22.83 in) |
|
for rackmounting |
19" 1/1, 4 HU |
Rack model (W × H × D) |
R&S®BBA150-A700/-BC1000/-D4007-E400 |
19" × 12 HU × 800 mm (31.5 in) |
|
R&S®BBA150-D800 |
19" × 20 HU × 800 mm (31.5 in) |
|
R&S®BBA150-A1300/-BC1250/-BC1500/ -BC2000 |
19" × 20 HU × 1000 mm (39.4 in) |
|
R&S®BBA150-A2500 |
19" × 35 HU × 800 mm (31.5 in) |
|
R&S®BBA150-BC3000 |
19" × 35 HU × 1000 mm (39.4 in) |
Environmental conditions
|
Temperature loading |
operating temperature range |
0 °C to +40 °C |
|
storage temperature range |
–20 °C to +70 °C |
Damp heat |
|
max. +40 °C at 95 % rel. humidity, without condensation |
Altitude |
operating altitude |
up to 2000 m |
|
storage altitude |
up to 4600 m |
Protection
|
Load VSWR |
|
infinite |
Interlock |
|
1 device interlock, 1 configurable interlock |
Input protection against bias voltage |
optional |
DC block level ≤ 50 V DC |
Transient voltage compatibility |
|
category II, in line with IEC 60364-4-443 |
Short-circuit breaking capacity |
|
automatic all-pole 20 A circuit breaker |
Thermal overload |
|
shutdown in case of thermal overload |