Frequency response |
at 600 Ω |
300 Hz to 3.4 kHz, (+1 dB/-3 dB (1 kHz)) |
Input impedance |
software-configurable setting |
600 Ω/10 kΩ |
Output impedance |
software-configurable setting |
600 Ω/60 Ω |
Input level |
software-configurable setting |
–30 dBm to +10 dBm at 600 Ω |
Output level |
|
0 dBm ± 1.5 dB at 600 Ω |
Signal quality |
at 600 Ω without CCITT-Filter |
THD < 0.5 %, S/N > 60 dB at 0 dBm input |
Digital audio interface to radio
|
|
|
LAN interface |
|
100BaseT |
Session control |
|
SIP in line with EUROCAE ED137-1 |
Audio stream |
|
RTP in line with EUROCAE ED137-1 |
Audio codec |
|
in line with ITU-T G.711, A-Law |
Microphone/headset interface
|
|
|
Microphone input level for dynamic microphone |
input impedance 200 Ω, with AGC |
1 mV (±20 dB) |
Microphone input level for electret microphone |
input impedance 330 Ω, with AGC |
100 mV (±20 dB) |
Headset output level |
output impedance 200 Ω |
max. 2 V |
Loudspeaker
|
|
|
Output power, built-in loudspeaker |
|
≤ 2 W at 8 Ω, adjustable |
Output power, external loudspeaker |
|
≤ 5 W at 8 Ω, adjustable |
Minimum level |
software-configurable setting |
1 mW to 2.5 W for external loudspeaker, 1 mW to 1.5 W for internal loudspeaker, 1 mV to 17 mV for headphone |
Electrical data
|
|
|
Power supply |
|
dual supply, 2 × 19 V (± 5 %) to 32 V (± 5 %) DC each |
Power consumption |
|
max. 1.0 A |
Electrical safety |
|
in line with EN 60950 |
EMC emissions |
|
in line with ETSI EN 301 489-1/-22; in line with MIL-STD-461F CE101 figure CE101-4, curve 2, CE102 figure CE102-1, RE101 figure RE101-2, RE102 figure RE102-1, RE102-3 fixed wing > 25 m (nose to tail), RE102-4 navy fixed and air force |
EMC immunity |
|
in line with ETSI EN 301 489-1/-22; in line with MIL-STD-461F CS101 figures CS101-1 and CS101-2, curve 2, CS114 ships (metallic, below decks), curve 2, RS101 figure RS101-2 (max. field strength 160 dBpT), RS103 ships ( metallic, below decks), RS103 navy (2 MHz to 1 GHz, field strength 10 V/m) |
Environmental data
|
|
|
Temperature range |
operational storage |
–20°C to +55°C –40°C to +70°C |
Humidity |
|
≤ 95 % at 55°C |
Mechanical data
|
|
|
Dimensions |
|
|
Front panel (W × H) |
model .02 and .03 (mounting in line with IEC 60297) |
19"/4, 3 HU 106.4 mm × 128.7 mm (4.2 in × 5.1 in) |
|
model .12 |
100.6 mm × 131 mm (4.0 in × 5.2 in) |
Body (W × H × D) |
|
93 mm × 103 mm × 120 mm (3.7 in × 4.1 in × 4.7 in) |
Weight |
|
< 0.8 kg (< 1.8 lb) |
Degree of protection |
|
IPx4 for front panel |