Add Limit Line to existing EMC32 Test to create a new list of critical frequencies

Question

I have saved an EMI Test and would like to add a new Limit Line to the existing Test, optionally I would like to create a new list of critical frequencies, based on the new limit line. How can I do this with EMC32?

Answer

Yes, you can do this. You can load the Test and you can add a new limit to the exisitig graphic. It is also possible to run a new EMI Evaluation to get new critical frequencies. Attached you you find a demo movie in avi file format. The avi movie will show you an example how to do it.

Please keep the following in mind: If the new limit is more stringent, you may get new critical frequencies. If the DUT is no more available, you are not able to run new Final measurements. In this case it may be useful to run the EMI Scan with a Test Receiver with Time Domain Scan and Final Detector.

Files:

Nom Dernière modification Taille
Open_Test_and_add_Limits.avi Aug 25, 2016 9 MB
Merci.

Votre demande a bien été envoyée !

Nous vous contacterons très bientôt.

Votre équipe de service Rohde & Schwarz

Demande de support
Veuillez spécifier le type de demande :
Veuillez spécifier le sujet.

Veuillez saisir votre demande.
Informations de contact

Veuillez saisir votre prénom.

Veuillez saisir une adresse électronique valide.

Veuillez saisir le nom de votre entreprise.

Veuillez saisir votre code postal.

Veuillez saisir votre nom.

Veuillez saisir votre numéro de téléphone.

Veuillez saisir votre ville.

Veuillez saisir le nom de votre ville.
Informations sur les produits


Veuillez saisir votre numéro de série.
(par exemple, 123456)
Contactez-moi par...*
Veuillez nous indiquer comment vous contacter.
Marketing de permission
Code de réponse de sécurité
show captcha

La saisie est incorrecte.
* Champ obligatoire
International Website