R&S®DST200 RF diagnostic chamber

Accurate radiated wireless device testing

R&S®DST200 RF diagnostic chamber
Open Lightbox
R&S®DST200 RF diagnostic chamber, front view

Key Facts

  • Anechoic RF chamber with highly effective shielding > 110 dB 
  • Wide frequency range from 400 MHz to 18 GHz 
  • Automated 3D positioners for OTA measurements
  • Compact dimensions for any lab environment 
  • Unique design maintains long-term, highly effective shielding

OTA measurements with smallest footprint

The R&S®DST200 RF diagnostic chamber is ideal for RF analysis during development. It supports a wide range of radiated test applications for wireless devices and fits on any R&D lab bench, for use at any time during the product design and optimization phases. The R&S®DST200 effectively allows for high first-time pass rates during final type approval, saving time and money.
The R&S®DST200 supports the radiated tests required in R&D, quality assurance, production and service. 

Caractéristiques & avantages

Shorter product development process

Shorter product development process for quicker time to market

Designing cutting-edge wireless devices such as multistandard smartphones requires extensive testing and verification. Radiated tests are essential during development and require special test tools and environments. To minimize total cost of ownership, testing tools and environments should be flexible enough for deployment at different sites.

Test tools from R&D to type approval
Open Lightbox

Test tools from R&D to type approval

High measurement accuracy and repeatability

The R&S®DST200 is a compact, RF shielded anechoic chamber with an integrated broadband cross-polarized
or circular-polarized test antenna for the frequency range from 400 MHz to 18 GHz.
Free-space conditions are achieved at the EUT test position through the optimized design and the layout of pyramidal RF absorbers. This minimizes parasitic loading of the EUT and antenna detuning from the conductive parts of the chamber frame.

R&S®DST-B150 manual 3D positioner
Open Lightbox

R&S®DST-B150 manual 3D positioner

R&S®DST-B150 manual 3D positioner is designed with RF transparent materials (Rohacell) 

Broadband test and communications antennas

All test antennas for the R&S®DST200 are single modules that the customer can easily change out by opening the top cover of the R&S®DST200.;
The R&S®DST-B270 and R&S®DST-B270 communications antennas can be mounted with horizontal or vertical orientation. This eliminates the effects of nulls in 3D patterns and provides a stable communications link.

R&S®DST-B215 cross polarized Vivaldi antennas
Open Lightbox

R&S®DST-B215 cross polarized Vivaldi antennas

Automated 3D positioner for OTA measurements

The optional R&S®DST-B160 3D positioner provides automated OTA measurements for TRP and TIS. The EUT is attached to a removable holder at the center of the positioner and rotated independently
on the azimuth and elevation axes by two servomotors. An optical sensor ensures high positioning accuracy. 
The supporting structure is made from material with very low relative permittivity to minimize field perturbation in the EUT quiet zone.

R&S®DST-B160 automated 3D positioner
Open Lightbox

R&S®DST-B160 automated 3D positioner

Individual calibration 

Individual calibration of the R&S®DST200 RF diagnostic chamber

The optional reference antennas for path loss calibration ensure accurate measurements that can be performed on-site. Two different
biconical broadband antennas are available. The R&S®TS-RANT3 has a frequency range from 400 MHz to 3 GHz for cellular and WLAN low frequency bands. The R&S®TS-RANT18 has a frequency range from 3 GHz to 18 GHz for precise calibration of higher frequencies.

R&S®DST-B120 positioner kit for calibration
Open Lightbox

R&S®DST-B120 positioner kit for calibration

Automated measurements

Automated measurements with ready-to-use test templates

The comprehensive R&S®AMS32 OTA performance measurement software supports various test applications with the R&S®DST200 RF diagnostic chamber:
- Verification of over-the-air (OTA) performance (TRP, TIS)
- Coexistence testing to verify receiver performance with multiple radio services active simultaneously in a wireless
device (e.g. LTE and Bluetooth®)
Easy test configuration for
parameters such as cellular band and power level.

Sample antenna pattern
Open Lightbox

Sample antenna pattern

Example of antenna pattern showing TRP for LTE band 13 (782 MHz)

Available options

Feed through panels
Produit
Désignation
R&S®DST-B101

Numéro de commande 1514.7778.02

Désignation

Filter Panel for R&S®DST200, 9-pin D-Sub, fiber-optic
 

R&S®DST-B102

Numéro de commande 1514.7784.02

Désignation

Interface Panel for R&S®DST200, 2 × N, 2 × RF cable

R&S®DST-B103

Numéro de commande 1514.7790.02

Désignation

Filter Panel for R&S®DST200, USB 2.0

R&S®DST-B104

Numéro de commande 1516.8407.02

Désignation

Filterpanel for R&S®DST200, 100V to 240V, AC

Test and communication antennas
Produit
Désignation
R&S®DST-B215

Numéro de commande 1527.3576.02

Désignation

Cross-Polarized Vivaldi Test Antenna for R&S®DST200

Selection of R&S®DST-B215, R&S®DST-B220 or R&S®DST-B231 is mandatory (factory-installed).

R&S®DST-B220

Numéro de commande 1518.4509.02

Désignation

Circular-Polarized Test Antenna for R&S®DST200

Selection of R&S®DST-B215, R&S®DST-B220 or R&S®DST-B231 is mandatory (factory-installed).

R&S®DST-B231

Numéro de commande 1518.5328.02

Désignation

Test Antenna Kit for R&S®DST200

Selection of R&S®DST-B215, R&S®DST-B220 or R&S®DST-B231 is mandatory (factory-installed).

R&S®DST-B270

Numéro de commande 1518.4515.02

Désignation

Linear-Polarized Communications Antenna for R&S®DST200

R&S®DST-B272

Numéro de commande 1518.4609.02

Désignation

Linear-Polarized Communications Antenna, 2 pcs., power splitter

Positioners
Produit
Désignation
R&S®DST-B120

Numéro de commande 1516.8659.02

Désignation

Positioner for Calibration Antennas

R&S®DST-B130

Numéro de commande 1515.1467.02

Désignation

Elevated EUT table for R&S®DST200

R&S®DST-B150

Numéro de commande 1515.1480.02

Désignation

Manual 3D Positioner for R&S®DST200

R&S®DST-B160

Numéro de commande 1516.8007.02

Désignation

Automated 3D Positioner for R&S®DST200

R&S®DST-B165

Numéro de commande 1519.3506.02

Désignation

Large Automated 3D Positioner for R&S®DST200

R&S®DST-U165

Numéro de commande 1519.3935.02

Désignation

Upgrade Kit for R&S®DST-B160

General analysis
Produit
Désignation
R&S®AMS32-DST

Numéro de commande 1518.5270.02

Désignation

OTA Measurement Software Basic Package for R&S®DST200

Selection of option as required for your application. Please contact your local Rohde & Schwarz expert.

R&S®AMS32-PK20

Numéro de commande 1518.5286.02

Désignation

R&S®AMS32-PK25

Numéro de commande 1518.5286.25

Désignation

General accessories
Produit
Désignation
R&S®DST-Z5

Numéro de commande 1518.9530.02

Désignation

Shipping Container for R&S®DST200

R&S®DST-Z18

Numéro de commande 1515.1473.02

Désignation

RF Cable, 18 GHz, 1.5 m, 2 × N connectors, high shielding effectiveness

R&S®DST-Z160

Numéro de commande 1518.5205.02

Désignation

EUT Holder for R&S®DST-B160

R&S®DST-Z165

Numéro de commande 1519.3941.02

Désignation

EUT Holder for R&S®DST-B165

R&S®TS-RANT3

Numéro de commande 1516.4224.02

Désignation

Linear-Polarized Calibration Antenna, 400 MHz to 3 GHz

R&S®TS-RANT3C

Numéro de commande 1516.4224.05

Désignation

Antenna Calibration Data for R&S®TS-RANT3C: gain, AF, VSWR

R&S®TS-RANT18

Numéro de commande 1516.4218.02

Désignation

Linear-Polarized Calibration Antenna, 3 GHz to 18 GHz

R&S®TS-RANT18C

Numéro de commande 1516.4218.05

Désignation

Antenna Calibration Data for R&S®TS-RANT18C: gain, AF, VSWR

Résumé de la vidéo

Chambre de diagnostic RF R&S®DST200

févr. 12, 2019

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.