R&S®ENV432 four-line V-network

For disturbance voltage measurements on three-phase EUTs

R&S®ENV432 four-line V-network
Open Lightbox
R&S®ENV432 four-line V-network
Open Lightbox
R&S®ENV432 four-line V-network
Open Lightbox
R&S®ENV432 four-line V-network
Open Lightbox
R&S®ENV432 four-line V-network
Open Lightbox
R&S®ENV432 four-line V-network
Open Lightbox
R&S®ENV432 four-line V-network, Front view R&S®ENV432 four-line V-network, Front High R&S®ENV432 four-line V-network, Side view R&S®ENV432 four-line V-network, Back view R&S®ENV432 four-line V-network, Back view R&S®ENV432 four-line V-network, Hero view

Key Facts

  • Frequency range 9 kHz to 30 MHz
  • Power handling capacity up to 32 A, constant current
  • Simulated impedance (50 μH + 5 Ω) || 50 Ω in line with CISPR 16-1-2
  • V-network in line with CISPR, EN, VDE, ANSI, FCC Part 15 and MIL-STD-461
  • Calibrated in line with CISPR 16-1-2

For disturbance voltage measurements on three-phase EUTs

The R&S®ENV432 four-line V-network meets CISPR 16‑1‑2, EN 55016-1-2 and ANSI C63.4 requirements for V-networks with a simulated impedance of (50 μH + 5 Ω) || 50 Ω in the frequency range from 9 kHz to 30 MHz. The R&S ENV432 comes with a Schuko socket (EUT 1) and a CEE 32 A socket (EUT 2) for connecting the equipment under test (EUT). The phase of the V-network can be selected manually using a front panel switch or automatically via TTL control inputs, which are compatible with the latest Rohde & Schwarz measuring receivers.

Caractéristiques & avantages

Air-core inductance and artificial hand

Air-core design and artificial hand

The R&S®ENV432 four-line V-network is based on
air-core inductances and contains an artificial hand to mimic the influence of a user's hand while measuring  disturbance voltage.

Attenuator

Built-in 10 dB attenuator pad

The R&S®ENV432 four-line V-network is equipped with a 10 dB attenuator pad to ensure standard impedance regardless of the measuring receiver input attenuation. 

Pulse limiter

Built-in pulse limiter (can be switched off)

A built-in pulse limiter that can be switched off protects
the measuring receiver's input from high energy radio frequency interference pulses.

Temperature monitoring

Automatic temperature monitoring

When the temperature inside the housing reaches about +50°C,  the R&S®ENV432 fans automatically switch on. This protects the V-network when the constant current load is high.

Remote control

Remote control with TTL levels (compatible with Rohde & Schwarz measuring receivers)

TTL control inputs that can be driven by controllers or
Rohde & Schwarz measuring receivers are provided for
remote control of phase selection in an automatic test
system. 

Available options

General
Produit
Désignation
R&S®EZ-21

Numéro de commande 1107.2087.03

Désignation

Control Cable, 3 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200

R&S®EZ-21

Numéro de commande 1107.2087.10

Désignation

Control Cable, 10 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200 

R&S®EZ-29

Numéro de commande 1326.6470.03

Désignation

Control Cable, 3 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

R&S®EZ-29

Numéro de commande 1326.6470.10

Désignation

Control Cable, 10 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.