R&S®HMC804x DC power supply series

A basic power supply from R&S Essentials

R&S®HMC804x DC power supply series
Open Lightbox
R&S®HMC804x DC power supply series
Open Lightbox
R&S®HMC804x DC power supply series
Open Lightbox
R&S®HMC804x DC power supply series
Open Lightbox
R&S®HMC804x DC power supply series
Open Lightbox
R&S®HMC804x DC power supply series
Open Lightbox
R&S®HMC804x DC power supply series
Open Lightbox
R&S®HMC804x DC power supply, front view R&S®HMC804x DC power supply, side view R&S®HMC804x DC power supply, front view R&S®HMC804x DC power supply, side view R&S®HMC804x DC power supply, front view R&S®HMC804x DC power supply, front view R&S®HMC804x DC power supply, side view

Key Facts

  • Clear display of all measured parameters
  • Galvanically isolated, floating and short-circuit proof outputs
  • Protective functions can be adjusted for each channel
  • Ideal power supply for hardware developers and labs
  • Intuitive, price-transparent online product configurator

Commençant à 1 210 CHF

Compact and easy to use

R&S®HMC804x DC power supplies are very energy efficient, helping them remain cool and quiet, even at maximum load. Practical interfaces and connectors make work quick and convenient while comfort functions are available for special application cases. One, two, or three channels – a wide range of functions and fundamental specifications make R&S®HMC804x DC power supplies ideal for:
-Development labs
-Industrial environments
-Manufacturing
-Education
You can now use the new online configurator to quickly design the R&S®HMC804x DC power supply you need with full price transparency. Get your request processed in no time by the authorized distribution partner of your choice.

Caractéristiques & avantages

Flexible channel configuration

All channels are galvanically isolated and can be combined to drive balanced  circuits or for higher voltages/currents.
Front panel: 4 mm safety sockets (R&S®HMC8041 including SENSE)
Rear panel: WAGO cage clamp for all channels including SENSE Convenient parallel and serial operation

Clear display of all measured parameters

The brilliant QVGA color display (320 x 240 pixel) shows real-time voltage, current and power with high resolution settings and readback of 1 mV and 0.1 mA/1.0 mA (depending on current and model). Low residual ripple from linear postregulation and high energy efficiency give it low heat dissipation and a quiet fan.

Flexible overcurrent protection

FuseLink allows you to freely combine the electronic fuses in each channel. Fuse delays help prevent early switching off due to short current spikes. Overcurrent/overvoltage protection can be set for each channel individually. The electronic fuses can be linked to other channels. Here, the channel that exceeds the maximum current level and all linked channels are switched off. Delay times can also be set to prevent premature switching off because of short current spikes.

Programmable sequences

Arbitrary waveforms can be generated for voltage and current. Functions can be configured and executed via the control panel or external interface.

EasyRamp function

Sometimes test sequences need to avoid spikes in supply voltage. The EasyRamp function can run a linear startup curve within a defined time span.

Remote control

Remote control via USB and LAN. R&S®HMC804x-G models also have an IEEE-488 (GPIB) interface.

Easy to use, price transparent configurator

We let customers choose the right T&M instrument quickly, easily, and with full price transparency. The R&S®HMC804x and other instruments in the R&S®Essentials portfolio can now be configured online with the following benefits:
- User-friendly and easy to navigate configurator
- Full cost transparency at every configuration step
- Fast order processing through authorized distribution partners 
- Next-day delivery from selected partners

Available models

Available models
Modèles
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Commençant à

R&S®HMC8041

Numéro de commande 3593.1006.02

Number of output channels
1
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
10 A
Commençant à
1 210 CHF

R&S®HMC8041-G

Numéro de commande 3593.1012.02

Number of output channels
1
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
10 A
Commençant à
1 500 CHF

R&S®HMC8042

Numéro de commande 3593.1029.02

Number of output channels
2
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
5 A
Commençant à
1 340 CHF

R&S®HMC8042-G

Numéro de commande 3593.1035.02

Number of output channels
2
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
5 A
Commençant à
1 640 CHF

R&S®HMC8043

Numéro de commande 3593.1041.02

Number of output channels
3
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
3 A
Commençant à
1 490 CHF

R&S®HMC8043-G

Numéro de commande 3593.1058.02

Number of output channels
3
Max. output power
100 W
Output voltage per channel
0 V to 32 V
Output current per channel
3 A
Commençant à
1 780 CHF
Specifications
Electrical specifications
Number of output channels 1/2/3
Total output power max. 100 W
Maximum output power per channel 100 W/50 W/33 W
Output voltage per channel 0 V to 32 V
Maximum output current per channel 10 A/5 A/3 A
Voltage ripple and noise (20 Hz to 20 MHz) R&S®HMC8041: < 1 mV (RMS)
R&S®HMC8042/43: < 450 µV (RMS)
Current ripple and noise (20 Hz to 20 MHz) R&S®HMC8041: < 1.5 mA (RMS) (meas.)
R&S®HMC8042/43: < 1 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 1 ms (meas.)
Programming resolution voltage 1 mV
Programming resolution current < 1 A: 0.1 mA (R&S®HMC8041: 0.5 mA)
≥ 1 A: 1 mA
Output measurements
Readback resolution voltage 1 mV
Readback resolution current < 1 A: 0.1 mA (R&S®HMC8041: 0.5 mA)
 ≥ 1 A: 1 mA
Readback accuracy voltage ±(% of output + offset) < 0.05 % + 2 mV
Readback accuracy current ±(% of output + offset) typ. < 0.05 % + 4 mA (R&S®HMC8041: typ. < 0.15 % + 10 mA)
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode -
Output sequencing
Trigger input/output
Arbitrary function ● (EasyArb)
Analog/modulation interface
Data logging
Display and interfaces
Display 3.5" QVGA
Rear panel connections Connector block with 4 lines per channel
Remote control interfaces: standard USB, LAN; R&S®HMC804x-G models with IEEE-488 (GPIB)
Remote control interfaces: optional
General data
Dimensions (W × H × D) 222 mm × 97 mm × 291 mm
Weight 2.6 kg
Rack installation R&S®HZC95 option

Available options

General accessories
Produit
Désignation
R&S®HZ10B

Numéro de commande 3594.6301.02

Désignation

Silicon Test Lead

banana to banana, 1 m (set of 5, blue)

R&S®HZ10R

Numéro de commande 3594.3860.02

Désignation

Silicon Test Lead

banana to banana, 1 m (set of 5, red)

R&S®HZ10S

Numéro de commande 3594.3877.02

Désignation

Silicon Test Lead

banana to banana, 1 m (set of 5, black)

R&S®HZC95

Numéro de commande 5800.2054.02

Désignation

19" rack adapter, 2HU, for R&S®NGE100B/NGC100/NPA and R&S®HMC series

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.