R&S®RTM3000 oscilloscope

R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 oscilloscope
Open Lightbox
R&S®RTM3000 Oscilloscope, Front view R&S®RTM3000 Oscilloscope, Front view R&S®RTM3000 Oscilloscope, Side view R&S®RTM3000 Oscilloscope, Side view R&S®RTM3000 Oscilloscope, Hero view R&S®RTM3000 Oscilloscope, Application Image

Key Facts

  • Bandwidth: 100 MHz to 1GHz
  • Sample rate: up to 5 Gsample/s
  • Memory depth: up to 80 Msample
  • ADC resolution: 10-bit
  • Display: 10.1’’ capacitive touchscreen

Commençant à 4 070 CHF

See more of your signal with the power of 10

Designed as daily problem-solving tool, the R&S®RTM3000 combines the power of ten (10-bit ADC, 10 times the memory and 10.1" touchscreen) with a Rohde & Schwarz probe interface for all Rohde & Schwarz probes.

  • Four times more vertical resolution than standard 8-bit ADCs
  • Maintains fast sampling rates at all times
  • 10.1" touchscreen with gesture support

Caractéristiques & avantages

Signal analysis: quick results

See small signal details in the presence of large signals

The R&S®RTM3000 features a customized Rohde & Schwarz designed 10-bit A/D converter that delivers a four-fold improvement over conventional 8-bit A/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltages across the switching device must be determined during the on/off times within the same acquisition.

10-bit A/D converter
Open Lightbox

10-bit A/D converter

10-bit A/D converter uncovers even small signal details and ensures a vertical resolution four times higher than traditional oscilloscopes.

Segmented memory

40 Msample standard and 80 Msample interleaved

The R&S®RTM3000 offers a class-leading memory depth: 40 Msample per channel are available, even 80 Msample in interleaved mode. This is eight times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates for more analysis results, e.g. when analyzing transients of switched-mode power supplies.

40 Msample standard memory
Open Lightbox

40 Msample standard memory

Capture and analyze pulsed and burst signals over a long period with up to 80 Msample standard acquisition memory

Capture more time at full bandwidth

Segmented memory: 400 Msample with history function

The R&S®RTM-K15 option with deep, segmented memory analyzes signal sequences over a long observation period. Protocol-based signals with communications gaps such as I²C or SPI can be captured over several seconds or minutes. Thanks to the variable segment size the 400 Msample memory is optimally utilized. In history mode, previous acquisitions to the maximum segmented memory depth of 400 Msample are available for further analysis.

400 Msample segmented memory
Open Lightbox

400 Msample segmented memory

Capture the longest time periods with class-leading 400 Msample memory

Logic analysis with the MSO option

16 additional digital channels

The R&S®RTM-B1 option turns every R&S®RTM3000 into an intuitive-to-use MSO with 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and timecorrelated to each other. For example, the delay between input and output of an A/D converter can conveniently be determined using the cursor measurements.

4-bit DAC signal change
Open Lightbox

4-bit DAC signal change

The R&S®RTM3000 captures and analyzes analog and digital signals synchronously and time-correlated with each other.

Waveform and pattern generator

Generate analog and digital stimuli

The R&S®RTM-B6 waveform and pattern generator up to 50 Mbit/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns for e.g. I2C, SPI, UART and CAN/LIN can be used.

Waveform and pattern generator
Open Lightbox

Waveform and pattern generator

In addition to common sine, square/pulse, ramp and noise waveforms, it outputs user-defined waveforms and 4-bit signal patterns.

Digital voltmeter

Measure and display electrical potential

The R&S®RTM3000 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Measurement functions include DC, AC+DC (RMS) and AC (RMS) – included as standard.

Digital voltmeter
Open Lightbox

Digital voltmeter

The 3-digit voltmeter measures and displays the electrical potential difference between two points in an electric circuit.

Frequency analysis mode

Difficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R&S®RTM3000 is activated at the push of a button and by simpling entering the center frequency and span. Thanks to the R&S®RTM3000 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128k points. Other practical tools include cursor measurements and autoset in frequency domain.

FFT of a square wave
Open Lightbox

FFT of a square wave

The high-performance FFT functionality analyzes signals up to 128k points.

Mask test mode

Mask tests quickly reveal whether a specific signal lies within defined tolerance limits. Masks assess the quality and stability of a DUT based on statistical pass/fail evaluation. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R&S®RTM3000. This pulse output can be used to trigger actions in the measurement setup.

Mask test with result statistics
Open Lightbox

Mask test with result statistics

The pass/fail evaluation assesses the quality and stability of the DUT

The best choice for power

See power signal details with up to 10-bit resolution

Even the smallest signal details of a high dynamic signal matter for power measurements. Verification of RDS(on) of a MOSFET is one example. The high ADC resolution of the R&S®RTM3000 oscilloscopes increases the vertical resolution up to 10 bit. Previously unseen signal details become visible and measurable. In the example of RDS(on), it makes it possible to measure the slope of the drain-to-source-voltage while the switch is closed.

Power analysis
Open Lightbox

Power analysis

Analyze the input, output and transfer function of switched-mode power supplies

Available models

Available models
Modèles
Bandwidth
Channels
Sample rate
Max. memory depth
Optional MSO
Commençant à

R&S®RTM3002

Numéro de commande 1335.8794.02

Bandwidth
100 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
4 070 CHF

R&S®RTM3004

Numéro de commande 1335.8794.04

Bandwidth
100 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
4 850 CHF

R&S®RTM3002 + RTM-B222

Numéro de commande 1335.8794P22

Bandwidth
200 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
4 870 CHF

R&S®RTM3004 + RTM-B242

Numéro de commande 1335.8794P24

Bandwidth
200 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
5 410 CHF

R&S®RTM3002 + RTM-B223

Numéro de commande 1335.8794P32

Bandwidth
350 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
8 380 CHF

R&S®RTM3004 + RTM-B243

Numéro de commande 1335.8794P34

Bandwidth
350 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
10 100 CHF

R&S®RTM3002 + RTM-B225

Numéro de commande 1335.8794P52

Bandwidth
500 MHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
10 700 CHF

R&S®RTM3004 + RTM-B245

Numéro de commande 1335.8794P54

Bandwidth
500 MHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
13 600 CHF

R&S®RTM3002 + RTM-B2210

Numéro de commande 1335.8794P62

Bandwidth
1 GHz
Channels
2
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
12 800 CHF

R&S®RTM3004 + RTM-B2410

Numéro de commande 1335.8794P64

Bandwidth
1 GHz
Channels
4
Sample rate
5 Gsample/s
Max. memory depth
80 Mpts
Optional MSO
16 digital channels
Commençant à
16 900 CHF
Specifications
Vertical system
Analog channels R&S®RTM3002; R&S®RTM3004 2; 4
Digital channels (opt.) 16
Bandwidth (-3 dB) R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) 100 MHz, 200 MHz, 350 MHz, 500 MHz, 1 GHz
Rise time R&S®RTM3002/3004 (with R&S®RTM-B2x2/-B2x3/-B2x5/-B2x10 options) 3.5 ns, 1.75 ns, 1 ns, 700 ps, 350 ps
Input impedance 50 Ω ± 1,5% (meas.), 1 MΩ ± 1 % (meas.) || 14 pF ± 1 pF (meas.)
Input sensitivity max. bandwidth in all ranges at 1 MΩ: 500 μV/div to 10 V/div
at 50 Ω: 500 μV/div to 1 V/div
ADC resolution 10 bit, up to 16 bit with high resolution decimation
DC gain accuracy offset and position = 0, maximum operating temperature change of ±5°C after self-alignment input sensitivity > 5 mV/div: ±1.5 % of full scale
input sensitivity > 5 mV/div: ±2 % of full scale
Acquisition system
Realtime sampling rate 2.5 Gsample/s; 5 Gsample/s, interleaved
Acquisition memory standard: 40 Msample (80 Msample interleaved)
with R&S®RTM-K15 option: 400 Msample segmented memory
Max. acquisition rate 64 000 waveforms/s
(2 000 000 in fast segmented memory mode)
Horizontal system
Timebase range selectable between 0.5 ns/div and 500 s/div
Accuracy (after delivery/calibration) ±2.5 ppm
Channel-to-channel skew < 200 ps (meas.)
Channel deskew ±500 ns
Trigger system
Standard Trigger types edge, width, video (PAL, NTSC, SECAM, PAL-M, SDTV 576i, HDTV 720p, HDTV 1080i, HDTV 1080p), pattern, line, serial bus, timeout
Optional Trigger types I2C, SPI, UART/RS-232/RS-422/RS-485, CAN/LIN,ARINC 429, MIL-STD-1553
Trigger sensitivity with DC, AC, LF reject, noise reject 1 GHz, 500 MHz, 350 MHz > 2.2 mVpp input sensitivity + 1 div (nom.) (input sensitivity: [mV/div]) 200 MHz, 100 MHz > 1.5 mVpp input sensitivity + 0.8 div (nom.) (input sensitivity: [mV/div]) 20 MHz > 0.6 mVpp input sensitivity + 0.4 div (nom.) (input sensitivity: [mV/div]) with HF reject all input sensitivities 1 div (meas.)
Analysis and measurement functions
Automatic measurements 32
Cursor measurements 4
Waveform mathematics 5 equations math on math (addition, substraction, multiplication, division, square, square root, abs. value, reciprocal, inverse, common log,, natural log., derivative, integral, low pass, high pass, track unipolar + bipolar on period, frequency, pulse width, duty cycle)
Mask testing
Mask definition elementary (tolerance mask around the signal)
History and segmented memory
Number of segments up to 34 952
Protocol trigger and decode
Supported protocols I2C, SPI, UART/RS-232/RS-422/RS-485, CAN, LIN, I2S, MIL-STD-1553, ARINC429
Waveform generator
Resolution 14-bit
Sample rate 250 Msample/s
Amplitude high Z; 50 Ω 20 mV to 5 V (Vpp); 10 mV to 2.5 V (Vpp)
DC offset high Z; 50 Ω ±5 V; ±2.5 V
Arbitrary sampling rate; memory depth max. 10 Msample/s; 32k points
Logic analyzer (MSO) functionality
Digital input channels 16
MSO Memory depth two logic probes: 40 Msample for every channel
one logic probe: 80 Msample for every channel
MSO Bandwidth 400 MHz (meas.)
MSO sampling rate 2.5 Gsample/s
MSO input impedance 100 kΩ ± 2 % || ~4 pF (meas.) at probe tips
Parallel buses up to 4
General data
Dimensions W × H × D 390 mm × 220 mm × 152 mm
(15.4 in × 8.66 in × 5.98 in)
Weight 3.3 kg (7.27 lb)
Display 10.1" WXGA TFT color display (1280 × 800 pixel)
Interfaces USB host with MTP, USB device, LAN, powerful web server for remote display and operation
Operating system Embedded

Available options

General
Produit
Désignation

Numéro de commande 1335.8988.02

Désignation

Mixed signal option, 400 MHz

The RTM-B1 MSO option is a powerful tool for debugging digital designs with a sampling rate of up to 5 GSa/s and a memory depth of up to 20 Msa.

R&S®RTM-B6

Numéro de commande 1335.8994.02

Désignation

Arbitrary waveform generator

Adds a 25 MHz signal generator and a 4-bit pattern generator to your R&S®RTM3000 oscilloscope.

Bandwidth upgrade
Produit
Désignation
R&S®RTM-B222

Numéro de commande 1335.9003.02

Désignation

Bandwidth upgrade of the R&S®RTM3002 to 200 MHz bandwidth

R&S®RTM-B223

Numéro de commande 1335.9010.02

Désignation

Bandwidth upgrade of the R&S®RTM3002 to 350 MHz bandwidth

R&S®RTM-B225

Numéro de commande 1335.9026.02

Désignation

Bandwidth upgrade of the R&S®RTM3002 to 500 MHz bandwidth

R&S®RTM-B2210

Numéro de commande 1335.9032.02

Désignation

Bandwidth upgrade of the R&S®RTM3002 to 1GHz bandwidth

R&S®RTM-B242

Numéro de commande 1335.9049.02

Désignation

Bandwidth upgrade of the R&S®RTM3004 to 200 MHz bandwidth

R&S®RTM-B243

Numéro de commande 1335.9055.02

Désignation

Bandwidth upgrade of the R&S®RTM3004 to 350 MHz bandwidth

R&S®RTM-B245

Numéro de commande 1335.9061.02

Désignation

Bandwidth upgrade of the R&S®RTM3004 to 500 MHz bandwidth

R&S®RTM-B2410

Numéro de commande 1335.9078.02

Désignation

Bandwidth upgrade of the R&S®RTM3004 to 1 GHz bandwidth

Serial triggering and decoding
Produit
Désignation

Numéro de commande 1335.8807.02

Désignation

I²C/SPI serial triggering and decoding

Triggering and decoding of I²C and 2-wire, 3-wire or 4-wire SPI buses

Numéro de commande 1335.8813.02

Désignation

UART/RS-232/RS-422/RS-485 serial triggering and decoding

Triggering and decoding of UART based protocols and RS-232, RS-422 as well as RS-485 buses

Numéro de commande 1335.8820.02

Désignation

CAN/LIN serial triggering and decoding

Triggering and decoding of CAN and LIN interfaces

Numéro de commande 1335.8842.02

Désignation

I²S/LJ/RJ/TDM triggering and decoding

Triggering and decoding of I²S buses

Numéro de commande 1335.8859.02

Désignation

MIL-1553 serial triggering and decoding

Triggering and decoding of MIL-STD-1553 buses

Numéro de commande 1335.8865.02

Désignation

ARINC 429 serial triggering and decoding

Triggering and decoding of ARINC 429 buses

General analysis
Produit
Désignation

Numéro de commande 1335.8907.02

Désignation

History and segmented memory

History and 400 Msample segmented memory.

Numéro de commande 1335.8920.02

Désignation

Power analysis

When analyzing power electronics, the input and output and the internal transfer function of the component have to be characterized. The power analysis option provides the necessary measurement functions, including inrush current, output spectrum and safe operating area (SOA).

Numéro de commande 1335.9178.02

Désignation

Frequency Response Analysis (Bode plot)

The R&S®RTM-K36 frequency response analysis (Bode plot) option lets you perform low-frequency response analysis on your oscilloscope easily and quickly. It characterizes the frequency response of a variety of electronic devices, including passive filters and amplifier circuits. For switch mode power supplies, it measures the control loop response and power supply rejection ratio.

Numéro de commande 1335.9184.02

Désignation

Spectrum analysis and spectrogram

The spectrum analysis option enhances the powerful FFT capability of R&S®RTM3000 oscilloscopes with spectrogram display

General accessories
Produit
Désignation
R&S®RTB-Z1

Numéro de commande 1333.1728.02

Désignation

Front cover

Protects the front of the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000

R&S®RTB-Z4

Numéro de commande 1335.9290.02

Désignation

Transit case with wheels for R&S®RTB

R&S®RTB-Z3

Numéro de commande 1333.1734.02

Désignation

Soft bag

Stores the R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 oscilloscope and accessories

Numéro de commande 1335.7875.02

Désignation

Accessory case for probes and small parts for all Rohde and Schwarz oscilloscopes

R&S®ZZA-RTB2K

Numéro de commande 1333.1711.02

Désignation

19" rackmount adapter for R&S®RTB2000, R&S®RTM3000 or R&S®RTA4000 with 5HU

R&S®RT-Z2T

Numéro de commande 1338.0007.02

Désignation

Probe adapter

Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface

Passive probes
Produit
Désignation

Numéro de commande 1333.2401.02

Désignation

Passive probe, 500 MHz, 10:1

Numéro de commande 1409.7550.00

Désignation

Passive probe, 500 MHz, 10:1

Numéro de commande 1333.1370.02

Désignation

Passive probe, 38 MHz, 1:1

Active single-ended probes
Produit
Désignation

Numéro de commande 1333.0815.02

Désignation

Active single-ended probe, 1 GHz, BNC interface

Numéro de commande 1418.7007.02

Désignation

Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4080.02

Désignation

Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Numéro de commande 1410.3502.02

Désignation

Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

Active differential probes
Produit
Désignation

Numéro de commande 1410.4715.02

Désignation

Active differential probe, 1 GHz, Rohde & Schwarz probe interface

Numéro de commande 1410.4409.02

Désignation

Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface

Power rail probes
Produit
Désignation

Numéro de commande 1800.5006.02

Désignation

Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface

2.0 GHz, 1:1, 50 kΩ, R&S probe interface

High voltage probes
Produit
Désignation

Numéro de commande 1333.0873.02

Désignation

250 MHz passive high voltage probe

Numéro de commande 1409.7720.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1409.7737.02

Désignation

400 MHz passive high voltage probe

Numéro de commande 1800.2307.02

Désignation

200 MHz High voltage differential probe

Numéro de commande 1800.2107.02

Désignation

100 MHz High voltage differential probe

Numéro de commande 1800.2207.02

Désignation

200 MHz High voltage differential probe

Numéro de commande 1800.2007.02

Désignation

100 MHz High voltage differential probe

Current probes
Produit
Désignation

Numéro de commande 1333.0850.02

Désignation

AC/DC 20 kHz current probe

Numéro de commande 1333.0844.02

Désignation

100 kHz current probe

Numéro de commande 1409.8204.02

Désignation

2 MHZ current probe

Numéro de commande 1409.7750K02

Désignation

10 MHZ current probe

Numéro de commande 1409.8210.02

Désignation

10 MHZ Current probe

Numéro de commande 1409.8227.02

Désignation

50 MHZ Current probe

Numéro de commande 1409.7766K02

Désignation

100 MHZ current probe

Numéro de commande 1409.8233.02

Désignation

100 MHZ current probe

Numéro de commande 1801.4932.02

Désignation

120 MHz current probe

Numéro de commande 1409.7772K02

Désignation

120 MHz current probe

EMC near field probes
Produit
Désignation

Numéro de commande 1147.2736.02

Désignation

E and H near-field probe set

Logic probes
Produit
Désignation
R&S®RT-ZL04

Numéro de commande 1333.0721.02

Désignation

400 MHz logic probe

Probe accessories
Produit
Désignation

Numéro de commande 1409.7789.02

Désignation

Power supply for probes

Power supply for R&S®RT-ZC10/20/30 probes, +/-12V DC, +/-2.5A

Numéro de commande 1410.4744.02

Désignation

External attenuator

10:1, 2.0 GHz, 1.3 pF, 60 V DC, 42 V AC (peak) for R&S®RT-ZD20/30 probes. Included in R&S®RT-ZD10.

Application bundles
Produit
Désignation
R&S®RTM-PK1

Numéro de commande 1335.8942.02

Désignation

Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), spectrum analysis and spectrogram (R&S®RTM-K37), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models

R&S®RTM-PK1US*

Numéro de commande 1335.9190.02

Désignation

Application bundle (R&S®RTM-K1, -K2, -K3, -K5, -K6, -K7, -K15, -K31, -K36, -K37 and -B6)

Application bundle contains triggering and decoding I²C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2) and CAN/LIN (R&S®RTM-K3), I²S (R&S®RTM-K5), MIL-1553 (R&S®RTM-K6), ARINC429 (R&S®RTM-K7) history and segmented memory (R&S®RTM-K15), power analysis (R&S®RTM-K31), frequency response analysis (R&S®RTM-K36), spectrum analysis and spectrogram (R&S®RTM-K37), arbitrary generator (R&S®RTM-B6) for R&S®RTM3000 models * ONLY distributed in North America

Application packages
Produit
Désignation
R&S®RTM3K-LSSB

Numéro de commande 1335.9149P02

Désignation

Low-speed serial bus package (R&S®RTM3004, -K1, -K2, -K15, -B1)

Low-speed serial bus package, contains base unit of R&S®RTM3004, trigger and decoding I2C/SPI (R&S®RTM-K1), UART/RS-232/RS-422/RS-485 (R&S®RTM-K2), History and Segmented Memory (R&S®RTM-K15) and Mixed Signal Option (R&S®RTM-B1)

R&S®RTM3K-HVP4

Numéro de commande 1335.9132P04

Désignation

High voltage power package (R&S®RTM3004, R&S®RT-ZHD60)

High voltage power package, contains base unit of R&S®RTM3004 and high voltage differential probe R&S®RT-ZHD60

R&S®RTM3K-HVP2

Numéro de commande 1335.9132P02

Désignation

High voltage power package (R&S®RTM3002, R&S®RT-ZHD60)

High voltage power package, contains base unit of R&S®RTM3002 and high voltage differential probe R&S®RT-ZHD60

R&S®RTM3K-PS

Numéro de commande 1335.9126P02

Désignation

Power supply package (R&S®RTM3004, -K31, R&S®RT-ZHD07, R&S®RT-ZC15B)

Power supply package, contains base unit of R&S®RTM3004, Power Analysis Option (R&S®RTM-K31), high voltage differential probe R&S®RT-ZHD07, and current probe R&S®RT-ZC15B

R&S®RTM3000 – Centre de médias

R&S®RTM3000 – Centre de médias

Afficher plus

Vidéos d'applications d'oscilloscopes – Centre de médias

Afficher plus

Ce qui pourrait également vous intéresser

Les 10 ans de Rohde & Schwarz en termes d'innovation dans le domaine des oscilloscopes

Plus d'information

Promotion sur les oscilloscopes

Choisissez la bonne promotion R&S en fonction de vos besoins individuels et faîtes d'économies

Plus d'information

Centre de webinaires sur les oscilloscopes pour les applications d'électronique de puissance et de conceptions numériques

Plus d'information

Logiciel d'enseignement dédié aux laboratoires étudiants multi-utilisateurs

Le logiciel R&S®CDS campus dashboard simplifie l'enseignement des groupes d'étudiants au sein des laboratoires équipés de plusieurs bancs de travail.

Informations produits

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.