Clock data recovery oscilloscope software

General analysis

Clock data recovery oscilloscope software
Open Lightbox
Clock data recovery oscilloscope software
Open Lightbox
Clock data recovery oscilloscope software, Software Clock data recovery oscilloscope software, Screenshot

Key Facts

  • Clock data recovery of embedded clocks in realtime
  • Support of hardware based serial pattern trigger

Oscilloscope software

The R&S®RTO-K13 realtime clock data recovery option activates the hardware CDR circuitry integrated into the R&S®RTO2000 digital oscilloscope. It provides realtime clock recovery for non-return-to-zero (NRZ) serial data up to 5.0 Gbps. The recovered clock may be used for triggering and jitter analysis.

Caractéristiques & avantages

Clock data recovery for analyzing embedded clock signals in realtime

The R&S®RTO-K13 clock data recovery option simplifies characterization of embedded clock signals. It is part of the unique digital trigger architecture of the R&S®RTO and permits realtime clock recovery:

  • Continuous eye and histogram measurements over a long period of time without postprocessing
  • CDR functions at full acquisition rate without restricting the oscilloscope functions
  • Display and analyze recovered clock signal

Open Lightbox

Serial pattern trigger

Combine the R&S®RTO with the optional hardware-based clock data recovery or the parallel clock signal to trigger on any serial interface telegram pattern of up to 16 byte with bit rates between 100 kbit and 2.5 Gbit. All analysis options remain available. Use jitter measurements, for example, to determine the influence of specific bit sequences on the protocol clock.

Open Lightbox

Available models

Available models
Modèles
Decode table
Eye on recovered clock
Jitter on recovered Clock
Trigger on recovered clock
Display recovered clock
Base unit

R&S®RTO-K13

Numéro de commande 1329.7383.02

Decode table
Eye on recovered clock
Jitter on recovered Clock
Trigger on recovered clock
Display recovered clock
Base unit

R&S®RTO6-K13

Numéro de commande 1801.6835.02

Decode table
Eye on recovered clock
Jitter on recovered Clock
Trigger on recovered clock
Display recovered clock
Base unit

Plus d'informations

Triggering & decoding 100Base-T1 BroadR-Reach Ethernet

Triggering & decoding 100Base-T1 BroadR-Reach Ethernet

Triggering & decoding real-world OABR automotive Ethernet with an oscilloscope.

More information

Triggering and decoding fast channel and slow channel of the SENT bus

Triggering and decoding fast channel and slow channel of the SENT bus

Discover how to decode SENT, including enhanced serial messages, displayed on an R&S®RTO.

More information

Debug CAN flexible data CAN-FD interfaces with an oscilloscope

Debug CAN flexible data CAN-FD interfaces with an oscilloscope

Discover how to debug CAN-FD, as displayed on an R&S®RTO.

More information

Symbolic decoding of a SENT bus

Symbolic decoding of a SENT bus

Discover how to set up symbolic decoding of a SENT bus, as displayed on an R&S®RTO.

More information

Decoding SENT bus with a handheld oscilloscope

Decoding SENT bus with a handheld oscilloscope

Discover how to easily deocde SENT using an R&S®RTH handheld oscilloscope.

More information

Decoding over three minutes of bus data using deep memory and ultrasegmentation

Decoding over three minutes of bus data using deep memory and ultrasegmentation

Discover how to decode bus data using deep memory and ultrasegmentation, as displayed on an R&S®RTA.

More information

Decoding CAN Flexible Data CAN-FD bus with a handheld oscilloscope

Decoding CAN Flexible Data CAN-FD bus with a handheld oscilloscope

Discover how to easily deocde CAN-FD using an R&S®RTH handheld oscilloscope.

More information

Decoding SENT bus signal

Decoding SENT bus signal

Discover how to easily deocde SENT using Rohde & Schwarz oscilloscopes, as displayed on an R&S®RTO.

More information

Serial bus decoding capability with an Oscilloscope

Serial bus decoding capability with an Oscilloscope

Discover the powerful decoding capability of Rohde & Schwarz oscilloscopes, as displayed on an R&S®RTO.

More information

Débogage sécurisé des alimentations intégrées

Dépannez plus rapidement les alimentations embarquées en déclenchant et en décodant leurs interfaces de commande I²C.

Plus d'information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.