Time domain analysis with VNA

Time domain analysis with VNA
Open Lightbox
Time domain analysis with VNA, Screenshot

Key Facts

  • Rise time resolution from 9 ps
  • Formats: lowpass impulse and step, bandpass impulse
  • Windowing/time gates: rectangular, hamming, Hann, Bohman, Dolph-Chebychev
  • Signal integrity test function with eye diagram

Time domain and distance-to-fault measurements

The time domain and distance-to-fault options display discontinuities, reflection factors or impedance versus delay/length. The TD option includes step and impulse response, lowpass/bandpass, frequency spacing and gated S-parameters. A wide selection of windows can be used to optimize the time domain response and suppress sidelobes due to the finite sweep range. Time gating and transforming back to the frequency domain eliminates unwanted responses.

Caractéristiques & avantages

Supported formats

The right format for the right application

The Rohde & Schwarz time domain option supports the following formats: lowpass impulse and step, bandpass impulse. The easy-to-use bandpass mode works with any set of a harmonic grid. The lowpass mode offers higher resolution factors in the DC value information.

Open Lightbox

Windowing/time gating

Optimize measurement results with windowing and gating

The finite sweep range in frequency domain measurements with discontinuous transitions at the start and stop frequency broadens the impulses and causes sidelobes (ringing) in the time domain response. Windowing can reduce this effect and optimize the time domain response. A time gate is used to eliminate unwanted responses that appear on the time domain transform. An active time gate acts on the trace in time domain and frequency domain representations.

Open Lightbox

Signal integrity

Valuable insights into the signal integrity of your design

The enhanced time domain option enables the R&S®VNA to implement a "virtual" signal generator for generating multilevel PAM signals (NRZ, PAM-4, PAM-8, PAM-16), including simulated lowpass behavior. The eye diagram calculated from the DUT's measured S-parameters provides an extensive overview of the system's signal integrity. Further building blocks for pre-emphasis, jitter, noise and equalization enable synthesization of the transmission system's transmitter and receiver parts.

Open Lightbox

Time domain resolution

Optimum resolution for optimum results

The Rohde & Schwarz time domain options offer a minimum resolution of up to 18 ps with an ambiguity range of up to 1.5 µs depending on the instrument of choice. Rise time resolution is as narrow as 9 ps. For more information, see the comparison table.

Available models

Available models
Modèles
Supported VNA
Maximum frequency/maximum # of points
Distance to fault
Enhanced time domain w/eye diagram
Maximum resolution [continuous sweep]/rise time
Maximum ambiguity range @ maximum resolution

R&S®ZNA-K2

Numéro de commande 1332.5336.02

Supported VNA
Maximum frequency/maximum # of points
67 GHz / 100,001
Distance to fault
-
Enhanced time domain w/eye diagram
ZNA-K20
Maximum resolution [continuous sweep]/rise time
30 ps / 15 ps
Maximum ambiguity range @ maximum resolution
1.5 µs

R&S®ZVAB-K2

Numéro de commande 1164.1657.02

Supported VNA
Maximum frequency/maximum # of points
110 GHz / 60,001
Distance to fault
-
Enhanced time domain w/eye diagram
-
Maximum resolution [continuous sweep]/rise time
18 ps / 9 ps
Maximum ambiguity range @ maximum resolution
55 µs

R&S®ZNB-K2

Numéro de commande 1316.0156.02

Supported VNA
Maximum frequency/maximum # of points
40 GHz / 100,001
Distance to fault
ZNB-K3
Enhanced time domain w/eye diagram
ZNB-K20
Maximum resolution [continuous sweep]/rise time
50 ps / 25 ps
Maximum ambiguity range @ maximum resolution
2.5 µs

R&S®ZNBT-K2

Numéro de commande 1318.8425.02

Supported VNA
Maximum frequency/maximum # of points
40 GHz/100,001
Distance to fault
R&S®ZNBT-K3
Enhanced time domain w/eye diagram
R&S®ZNBT-K20
Maximum resolution [continuous sweep]/rise time
50 ps/50 ps
Maximum ambiguity range @ maximum resolution
2.5 µs

R&S®ZND-K2

Numéro de commande 1328.5393.02

Supported VNA
Maximum frequency/maximum # of points
8.5 GHz / 5001
Distance to fault
ZND-K3
Enhanced time domain w/eye diagram
-
Maximum resolution [continuous sweep]/rise time
235 ps / 117 ps
Maximum ambiguity range @ maximum resolution
6.25 µs

R&S®ZVL-K3

Numéro de commande 1306.0201.02

Supported VNA
Maximum frequency/maximum # of points
13.6 GHz / 4,001
Distance to fault
ZVL-K2
Enhanced time domain w/eye diagram
-
Maximum resolution [continuous sweep]/rise time
147 ps / 73 ps
Maximum ambiguity range @ maximum resolution
2.94 µs

R&S®ZNL-K2

Numéro de commande 1323.1819.02

Supported VNA
Maximum frequency/maximum # of points
6 GHz / 100,001
Distance to fault
ZNL-K3
Enhanced time domain w/eye diagram
-
Maximum resolution [continuous sweep]/rise time
333 ps / 166 ps
Maximum ambiguity range @ maximum resolution
16.7 µs

Available options

General
Produit
Désignation
R&S®ZNA-K20

Numéro de commande 1332.4746.02

Désignation

Extended time domain analysis

incl. eye diagram, for R&S®ZNA

R&S®ZNB-K20

Numéro de commande 1326.8072.02

Désignation

Extended time domain analysis

R&S®ZNBT-K20

Numéro de commande 1319.4400.02

Désignation

Extended time domain analysis with eye diagram

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.