Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
734 Results
The measurement speed for spurious signal measurements is mainly defined by the spectrum analyzer sweep speed. With traditional swept spectrum analyzers and tight spurious limits the measurement can easily take hours or even a full day. This application note describes the differences in sweep speed between swept spectrum analyzers and modern spectrum analyzers with a wide-band FFT process, and how this improves the measurement speed for general spurious measurement.
10-Jul-2012 | AN-No. 1EF80
This application note explains how to detect, characterize, find and document interferers in cellular networks using the R&S®FSH spectrum analyzer.First it explains how to use the spectrum and interference analysis functions during each step of interference hunting. It also illustrates the explanations with a common interferer example. Then it points out the most common interference sources in cellular networks and gives tips on how to identify them.
21-Oct-2014 | AN-No. 1EF89
Audio Analyzers UPD and UPL with their large variety of functions provide practically all measurement procedures required in audio technology. Thanks to the Universal Sequence Controllers UPD-K1 and UPL-B10, which are available as options, the user is able to considerably expand the range of functions to suit his particular requirements. It is possible, for instance, to add complete measurement functions - eg measurement of ohmic resistance - and to read out, convert or reload sweep results or to add new scale labelling (eg group delay). Another example is the analysis of sweep curves and the display of results in a window next to the curve. As far as softkey labelling and functions are concerned, operation of the sequence control programs is analogous to the softkey control of the UPD/UPL graphics display.
04-Jun-1998 | AN-No. 1GA16
All digital oscilloscopes are temporarily blind. During this blind time the user will miss critical signal events at his device under test. Thus, it is necessary to understand the impact of blind time to the measurement. This application note explains the background of blind time and points out why a high acquisition rate is important. It furthermore explains the R&S RTO oscilloscope capabilities and how they help for faster debugging, measurement and analysis.
17-May-2011 | AN-No. 1ER02
Nearly all tests in accordance with the Bluetooth low energy test specification V4.0 [1] can be performed using the R&S®CBT alone. Some tests additionally call for signal generators to provide interference signals. This application note describes the tests performed with additional equipment and presents straightforward solutions based on the R&S®CBTgo software.
18-Jul-2013 | AN-No. 1MA200
Nearly all tests in accordance with the test specification* can be performed with the R&S® CMU200/CBT alone. Some tests additionally call for signal generators to provide interference signals and also require spectrum analyzers. This application note describes the tests performed with additional equipment and presents straightforward solutions based on the CBTgo software.
06-Mar-2013 | AN-No. 1MA106
This document describes the typical measurements performed on mixers and how they can be implemented on the ZVA Vector Network Analyzer with the ZVA-K4 Frequency Conversion option. The document describes the concept and setups required to perform Conversion Loss, Isolation, Intermodulation and Reflection measurements.
06-May-2009 | AN-No. 1EZ58
This application notes introduces the Multi-Standard Radio Analyzer function of the R&S®FSW and shows how it performs the measurement on multi-standard radio transmitters. It reveals interactions caused by the coexistence of signals of different cellular standards and localizes the root cause. With an example of a base station signal consisting of three radio access technologies (GSM/WCDMA/LTE FDD) it shows how easy interactions can be found. The R&S®FSW is the ideal tool for trouble shooting tasks with its combination of a large bandwidth and the versatile Multi-Standard Radio Analyzer in one measurement instrument.
17-Jul-2012 | AN-No. 1EF83
3GPP Release 9 Technical Specification (TS) 37.141 covers multistandard radio base station conformance testing. Multistandard radio includes four standards of mobile communications: GSM, WCDMA, TD-SCDMA, and LTE. This application note introduces the concept of multistandard radio base stations as well as solutions for transmitter and receiver tests based on Rohde & Schwarz signal generators and Rohde & Schwarz signal and spectrum analyzers.
06-Jul-2012 | AN-No. 1MA198
Joint solutions of R&S® and COMPRION®
The GSMA specified a global standard for remote provisioning and management of the embedded Universal Integrated Circuit Card (eUICC) in the machine-to-machine (M2M) environment as well as the consumer devices via Over the Air (OTA) methodology.This application note describes GSMA compliant remote eUICC provisioning test solution based on R&S® CMW500/CMW290/CMX500 and COMPRION® eUICC Profile Manager software tool. Moreover, an eUICC provisioning method for GSMA Security Accreditation Scheme (SAS) compliant consumer devices by adopting COMPRION® eSIM Test Profile Service is introduced which is essential for RF, protocol testing on R&S®CMW500/CMW290/CMX500 for eSIM capable consumer devices.
03-Jun-2020 | AN-No. GFM342
Frequency converters e.g. in satellite transponders need to be characterized not only in terms of amplitude transmission but also in terms of phase transmission or group delay, especially with the transition to digital modulation schemes. They often do not provide access to the internal local oscillators This application note describes a method using the R&S ZVA to measure group delay of mixers and frequency converters with an embedded local oscillator very accurately. The key aspect of this new technique is, that the network analyzer applies a 2-tone signal to the frequency converter. By measuring the phase differences between the two signals at the input and at the output, it calculates group delay and relative phase between output and input.
27-Aug-2012 | AN-No. 1EZ60
radiated conformance testing according to TS 38.141-2, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes all mandatory radiated RF transmitter tests (TS 38.141-2, chapter 6), according to Release 16.Furthermore, this document provides a brief introduction about the different R&S OTA antenna test solutions and how they are applicable for base station conformance testing. Rohde & Schwarz offers solutions for any test case that is mentioned in this application note.
20-Dec-2019 | AN-No. GFM324
Rohde & Schwarz signal generators can be connected in various ways to system controllers (typically PCs) and external PC peripherals. Although most of these connection operations are also explained in the instrument manuals, it is not always easy to maintain an overview. Operating manuals commonly focus on explaining a dedicated feature of a single instrument. This application note examines a range of typical user tasks and how to solve them with the different instruments.
26-Apr-2013 | AN-No. 1GP72
A typical application for signal generators and spectrum analyzers is measuring nonlinearities of RF amplifiers. This application note discusses the basics of nonlinearities and describes the nonlinearity measurement using the R&S Value Instruments RF Signal Generator R&S®SMC100A and Spectrum Analyzer R&S®FSC.
20-May-2014 | AN-No. 1MA71