Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
62 Results
Useful tips and tricks for your first measurement experience
Resistors, capacitors and inductors are the most basic components in electric circuits. It must be ensured that they work properly and accurately. Therefore, they need to be tested thoroughly during circuit design. This is usually done using LCR meters, which have become indispensable in the lab and in production. This application note looks at how to perform basic capacitor and inductor measurements accurately and reliably.
22-Feb-2024 | AN-No. 1GP142
This application note proposes a digital level shifter for connecting the I2S interfaces R&S®UPP-B2 and R&S®UPV-B41 to devices under test with a logic voltage different from 3.3 V.
27-Mar-2020 | AN-No. 1GA71
Applications requiring higher voltages or currents, or a stack of voltage sources with taps in-between, demand the combination of several DC power supply channels in series or in parallel.All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies.When a large number of power supply channels is used, it is desirable to have a tool for configuring all instruments and channels from one user interface, and for keeping an overview over the states and measurement values from all channels.The application program of this application note provides such a tool. The document contains background information and user manual for the software.
27-Aug-2020 | AN-No. 1GP127
Source measure units R&S®NGU401 and R&S®NGU201 are capable of precise current measurements from sub-microampere up to ampere. This application note provides a tool which generates a voltage or current sweep using the arbitrary function of the instruments. A fast log captures voltage and current values during the sweep. Subsequently the application program determines the voltage and current value for each sweep step and plots the results in an I-V curve .The tool can be utilized to characterize all kinds of two-pole devices like diodes, LEDs and solar panels.This application note can also be used in connection with DC power supplies R&S®NGM201 and R&S®NGM202.
15-Feb-2021 | AN-No. 1GP129
The application program of this application note provides a tool for cycling battery samples, using two-quadrant DC power supplies from Rohde & Schwarz. The batteries can be repeatedly charged and discharged while collecting information about open-circuit voltage, loaded voltage and internal resistance, depending on the charged and discharged capacity. The tool provides a variety of charts for displaying the collected data. It can be used for characterizing battery samples, as well as for creating battery models which can be used in the battery simulations of R&S®NGU201 and R&S®NGM200.This tool is meant for the use by knowledgeable experts. The application note does not provide instructions on how to properly charge and discharge batteries.
17-Dec-2021 | AN-No. 1GP130
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range. Dynamic impedance measurements allow to perform these measurements while sweeping the test signal frequency or other parameters like test signal level and DC bias. This application note provides a PC-based software tool for comfortably setting the sweeps and displaying the results in numerous charts.
14-Mar-2022 | AN-No. 1GP132
This application note applies to DC power supplies R&S®NGL200, R&S®NGM200, R&S®NGP800, R&S®NGU201 and R&S®NGU401, as well as LCR meters R&S®LCX100 and R&S®LCX200. It provides an overview over ethernet-based remote services provided by the referenced R&S® instruments. These services comprise an instrument web page, VNC remote control and FTP file transfer between the instrument and a remote computer. The application note gives instructions on how to set up the instrument and the remote computer in order to be able to utilize these services.
19-May-2022 | AN-No. 1GP135
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126
This application program supports the logging and fast logging functionality of the power supplies R&S® NGM200, NGU201 and NGU401. Standard logging is also supported with power supply R&S® NGL200 and NGP800. Power supplies R&S® NGA100 and NGE100 are supported in the data collection mode. Charting functionality is available for logged voltage, current and power values.
14-Nov-2019 | AN-No. 1GP122
Today’s complex circuits must integrate several components that feed on different power levels. A robust circuit that ensures interoperability of these components needs carefully designed, clean and stable power distribution networks for power timing. At lower voltage levels, tolerance is defined in percentages and can make precise measurements challenging.
22-Apr-2024
Load pull is a powerful method for characterizing RF power amplifiers through impedance variation. Load pull enables model extraction and validation as well as performance, ruggedness and efficiency testing.
02-Sep-2020
Gated spectrum method with the R&S®PR200
03-Feb-2020
Impedance measurements with vector network analyzers require maximum precision. The R&S®ZNL is able to characterize a broad range of impedances with the lowest uncertainty among its competitors in the same class.
02-Oct-2019
This application note demonstrates the use of the Measurement Receiver to calibrate the signal output level of a Signal Generator.Calibration in this application is a two-step process.► The absolute output level of the signal source, at a fixed level, is measured using a thermal power sensor (e.g. NRP50T), which in turn outputs its reading to the FSMR.► Output power calibration over a wider dynamic range (to lower power) is performed by connecting the FSMR to the signal source directly, and sweeping the power of the signal source.The FSMR offers a nominal total measurement uncertainty of <0.015 dB +/- 0.005 dB per 10dB step. At 1GHz, the power measurement range covers -152 dBm to +30 dBm. It is this intrinsic linearity, that the accuracy of the calibration relies upon.Absolute power measurement uncertainty, for the NRP50T thermal power sensor used in this Application Note, is 0.040 dB to 0.143 dB.This process may be repeated at multiple frequencies. Calibration values are automatically stored and managed by the FSMR. Measurement frequencies for calibrations are stored, will be automatically recalled by the FSMR, by re-selection of those frequencies.
31-Dec-2021 | AN-No. 1SL377
Performing precompliance measurements on power supplies requires using a line impedance stabilization network (LISN) for results that can be compared to limit values. While LISNs are standard in any precompliance lab, often no LISN is available for early R&D testing. If high accuracy is not your goal and you just need a simple tool for debugging, you can build your own LISN. Rohde & Schwarz oscilloscopes with powerful FFT analysis, are ideal for optimizing EMI filters or debugging unwanted emissions during development.
14-Jan-2021
Make more accurate power rail measurements.
09-Jul-2020
Since June 2017 almost all radio transmitters and receivers sold or put into operation in the European Union have to be tested for immunity against interferers in adjacent frequency bands. ETSI standard EN 303 345 defines the tests to be performed on broadcast sound receivers, and the requirements to be passed.This application note describes the test procedures and provides script files and interferer signals for the Broadcast Test Center R&S®BTC.
29-May-2020 | AN-No. 1GP117
Timing components such as low jitter oscillators and clocks are necessary to facilitate increasing data rates in high speed digital designs. As part of the overall system design, the components also have to perform in the system’s non-ideal power integrity environment and limit the power supply induced phase noise and jitter from power rail disturbances. Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
Primer
A power sensor is a fundamental measurement tool in RF engineering. However, today's marketplace is filled with myriad choices, and many are making bold claims about attributes such as measurement speed and readings per second. As a result, it can be difficult to cut through the hyperbole and determine which sensor will actually meet the requirements of a specific measurement.This primer outlines the basics of RF power sensors and highlights a few key characteristics that will help you select the best one for each application. The narrative has three parts. First, we focus on choosing the right type of sensor: multipath, wideband, average power and thermal can satisfy slightly different measurement needs. The second section covers the five major attributes of sensor performance, and what to look for relative to your requirements. Finally, we outline three ways to integrate a sensor into your measurement application.
26-May-2021
Analyzing high speed datacom interfaces is an important task and ensures signal integrity. One major challenge of this analysis is the connection between the physical interface and the oscilloscope, as most of the datacom interfaces do not provide test connections suitable for RF. A test fixture is required as a bridge between the high speed datacom IF and the RF connector of the oscilloscope, but this will affect the signal integrity measurement. The R&S®RTP and R&S®RTO2000 oscilloscopes with the advanced jitter option can analyze and separate jitter contributions. Additionally, the option can evaluate the impact of test fixtures and traces inherently and give the user a good understanding of the impact of their test setup.
31-Mar-2021
NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery simulators. Testing battery management systems with Rohde & Schwarz power supplies NGM200, NGL200 The R&S®NGL200 and R&S®NGM200 can simulate battery cells when testing battery management systems and replace far more expensive dedicated battery
08-Jun-2020
10BASE-T1S Ethernet enables the integration of diverse sensors into an automotive-Ethernet vehicle supply system, for example short-range radar sensors for detecting blind spots or ultrasonic sensors for the parking assistant. For reliable operation of the functions, data transmission over 10BASE‑T1S Ethernet must be assured at all times and in every climatic environment. Functionality must be tested during development and in production. Only 10BASE-T1S Ethernet interfaces that have passed compliance testing in line with IEEE 802.3cg can be deployed in vehicles. Consequently, vehicle manufacturers and their suppliers need measuring equipment that allows them to perform these tests quickly and reliably.
15-May-2020
Using VISA (Virtual Instrument Software Architecture) several interfaces allow communication between your computer and instruments. This application note describes the usage of both - R&S® VISA- NI VISA running on Microsoft Windows 10™ with the following connection types: ► USB VCP (Virtual Com Port), also called USB CDC (Communications Device Class) ► USB TMC (Test and Measurement Class)► Ethernet Raw Port Socket► Ethernet in general e.g. VXI11 or HislipAll the examples are shown using the R&S® HMC8042 unless otherwise stated. There may be some difference when integrating other devices. As example some interface types are not available on every unit.This application note does not claim to be complete. All information has been compiled with care. However, errors can’t be ruled out.
28-Oct-2021 | AN-No. 1SL374
With the R&S®Pulse Sequencer radar simulation software, users can easily and intuitively create scenarios for simulation of angle of arrival (AoA). Together with multiple coupled R&S®SMW200A vector signal generators, this solution allows quick and thorough performance characterization of all types of direction finding equipment such as devices that use amplitude comparison, interferometric or time difference of arrival (TDOA) techniques. This document describes our test solution for testing devices that use amplitude comparison techniques.
02-Apr-2020
Thanks to their multichannel capability, oscilloscopes are ideal for multichannel applications such as the analysis of MIMO signals (e.g. 5G NR, WLAN), multi-antenna radar signals and differential high-speed digital signals (e.g. USB 3.x). These applications require the oscilloscope channels to be tightly aligned. This means the channel-to-channel residual skew has to be measured accurately so that it can be compensated. The channel-to-channel phase mismatch is reduced to a minimum, which plays a crucial role in achieving reliable measurement results.
06-May-2020
Oscilloscopes are basic everyday instruments for engineers and electricians. Maintenance tasks, however, sometimes require very specific measurements that are not available as standard functionality or are difficult to set up manually. With the R&S®RTH-K38 user scripting option, engineers can now design their own measurement function and a simple user interface. This paper describes how to use this unique feature for railway maintenance work.
06-May-2020
Testing radar warning equipment in realistic scenarios is crucial to reliable field performance. This typically involved dedicated instruments or test systems. Commercial vector signal generators (VSG) such as the R&S®SMW200A from Rohde & Schwarz have become a very attractive alternative thanks to their increased available bandwidth and processing power.
13-Aug-2020
Automating measurement setups is advantageous for multiple reasons. It saves time in case of repeated measurements and in hazardous environments, instruments can be operated from a distance. The measurements are repeatable because they are always performed with a defined procedure, leading to higher test confidence.But in remote control applications, users often perceive synchronization and binary transfers as challenging. Therefore, this application note focuses on binary transfer of data to and from the instrument and shows code example to demonstrate the ease of use.
31-Mar-2022 | AN-No. 1SL381
The R&S®ZNA vector network analyzer with integrated LO output and direct IF input options is a simple, cost-effective solution for 2-port and 4-port measurements using Rohde & Schwarz mmWave converters.