61 Results
Useful tips and tricks for your first measurement experience
Resistors, capacitors and inductors are the most basic components in electric circuits. It must be ensured that they work properly and accurately. Therefore, they need to be tested thoroughly during circuit design. This is usually done using LCR meters, which have become indispensable in the lab and in production. This application note looks at how to perform basic capacitor and inductor measurements accurately and reliably.
22-Feb-2024 | AN-No. 1GP142
Source measure units R&S®NGU401 and R&S®NGU201 are capable of precise current measurements from sub-microampere up to ampere. This application note provides a tool which generates a voltage or current sweep using the arbitrary function of the instruments. A fast log captures voltage and current values during the sweep. Subsequently the application program determines the voltage and current value for each sweep step and plots the results in an I-V curve .The tool can be utilized to characterize all kinds of two-pole devices like diodes, LEDs and solar panels.This application note can also be used in connection with DC power supplies R&S®NGM201 and R&S®NGM202.
15-Feb-2021 | AN-No. 1GP129
The application program of this application note provides a tool for cycling battery samples, using two-quadrant DC power supplies from Rohde & Schwarz. The batteries can be repeatedly charged and discharged while collecting information about open-circuit voltage, loaded voltage and internal resistance, depending on the charged and discharged capacity. The tool provides a variety of charts for displaying the collected data. It can be used for characterizing battery samples, as well as for creating battery models which can be used in the battery simulations of R&S®NGU201 and R&S®NGM200.This tool is meant for the use by knowledgeable experts. The application note does not provide instructions on how to properly charge and discharge batteries.
17-Dec-2021 | AN-No. 1GP130
This application note applies to DC power supplies R&S®NGL200, R&S®NGM200, R&S®NGP800, R&S®NGU201 and R&S®NGU401, as well as LCR meters R&S®LCX100 and R&S®LCX200. It provides an overview over ethernet-based remote services provided by the referenced R&S® instruments. These services comprise an instrument web page, VNC remote control and FTP file transfer between the instrument and a remote computer. The application note gives instructions on how to set up the instrument and the remote computer in order to be able to utilize these services.
19-May-2022 | AN-No. 1GP135
All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies. In the case of parallel and serial connections it is usually desired to switch all channels simultaneously on and off for protecting the supplied circuitry and for avoiding overcurrent on other power supply channels.This application note describes how to connect and configure DC power supplies R&S®NGL200 and R&S®NGM200 for synchronized on and off switching of all channels across multiple power supplies.
15-Jun-2020 | AN-No. 1GP126
Applications requiring higher voltages or currents, or a stack of voltage sources with taps in-between, demand the combination of several DC power supply channels in series or in parallel.All channels of DC power supplies R&S®NGL200 and R&S®NGM200 are isolated against the grounding equipment conductor and against the digital ground of the instrument. Therefore, channels can be connected in parallel for increasing the current capability, or in series for achieving higher voltages or dual-voltage supplies.When a large number of power supply channels is used, it is desirable to have a tool for configuring all instruments and channels from one user interface, and for keeping an overview over the states and measurement values from all channels.The application program of this application note provides such a tool. The document contains background information and user manual for the software.
27-Aug-2020 | AN-No. 1GP127
This application program supports the logging and fast logging functionality of the power supplies R&S® NGM200, NGU201 and NGU401. Standard logging is also supported with power supply R&S® NGL200 and NGP800. Power supplies R&S® NGA100 and NGE100 are supported in the data collection mode. Charting functionality is available for logged voltage, current and power values.
14-Nov-2019 | AN-No. 1GP122
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range. Dynamic impedance measurements allow to perform these measurements while sweeping the test signal frequency or other parameters like test signal level and DC bias. This application note provides a PC-based software tool for comfortably setting the sweeps and displaying the results in numerous charts.
14-Mar-2022 | AN-No. 1GP132
This application note proposes a digital level shifter for connecting the I2S interfaces R&S®UPP-B2 and R&S®UPV-B41 to devices under test with a logic voltage different from 3.3 V.
27-Mar-2020 | AN-No. 1GA71
Automating measurement setups is advantageous for multiple reasons. It saves time in case of repeated measurements and in hazardous environments, instruments can be operated from a distance. The measurements are repeatable because they are always performed with a defined procedure, leading to higher test confidence.But in remote control applications, users often perceive synchronization and binary transfers as challenging. Therefore, this application note focuses on binary transfer of data to and from the instrument and shows code example to demonstrate the ease of use.
31-Mar-2022 | AN-No. 1SL381
With the R&S®Pulse Sequencer radar simulation software, users can easily and intuitively create scenarios for simulation of angle of arrival (AoA). Together with multiple coupled R&S®SMW200A vector signal generators, this solution allows quick and thorough performance characterization of all types of direction finding equipment such as devices that use amplitude comparison, interferometric or time difference of arrival (TDOA) techniques. This document describes our test solution for testing devices that use amplitude comparison techniques.
02-Apr-2020
Measuring and optimizing the characteristics of individual elements within an antenna array for beamforming performance of Qualcomm 5G mmWave modems SDX50 and SDX55.
25-Feb-2020
Timing components such as low jitter oscillators and clocks are necessary to facilitate increasing data rates in high speed digital designs. As part of the overall system design, the components also have to perform in the system’s non-ideal power integrity environment and limit the power supply induced phase noise and jitter from power rail disturbances. Measuring the power supply noise rejection (PSNR) requires accurate generation and leveling of artificial, sinusoidal disturbances and measurement of resulting phase-noise and jitter impairments.
30-Sep-2020
Analyzing high speed datacom interfaces is an important task and ensures signal integrity. One major challenge of this analysis is the connection between the physical interface and the oscilloscope, as most of the datacom interfaces do not provide test connections suitable for RF. A test fixture is required as a bridge between the high speed datacom IF and the RF connector of the oscilloscope, but this will affect the signal integrity measurement. The R&S®RTP and R&S®RTO2000 oscilloscopes with the advanced jitter option can analyze and separate jitter contributions. Additionally, the option can evaluate the impact of test fixtures and traces inherently and give the user a good understanding of the impact of their test setup.
31-Mar-2021
Phase difference is the key parameter when characterizing direction finding (DF) scenarios. To analyze DF equipment, the phase difference needs to be determined before measuring other parameters such as the bearing. The R&S®VSE-K6A multichannel pulse analysis software in combination with a Rohde & Schwarz oscilloscope provides phase difference measurements even in challenging environments, utilizing the test equipment’s advanced trigger capabilities.
02-Mar-2021
CST® Filter Designer 3D, which is part of the CST Studio Suite® simulation software from Dassault Systèmes, is a complete synthesis tool for filters and diplexers. It provides a range of solutions throughout the design process of coupled resonator filters and even beyond with its VNA based tuning capability. CST Filter Designer 3D assists in tuning filter hardware, significantly reducing the time for optimizing a device to meet the expected specifications. An attractive instrument to obtain fast data reading for realtime filter tuning is the R&S®ZNB vector network analyzer from Rohde & Schwarz.
27-Nov-2019
The R&S®ZNA vector network analyzer with integrated LO output and direct IF input options is a simple, cost-effective solution for 2-port and 4-port measurements using Rohde & Schwarz mmWave converters.
19-Jul-2021
10BASE-T1S Ethernet enables the integration of diverse sensors into an automotive-Ethernet vehicle supply system, for example short-range radar sensors for detecting blind spots or ultrasonic sensors for the parking assistant. For reliable operation of the functions, data transmission over 10BASE‑T1S Ethernet must be assured at all times and in every climatic environment. Functionality must be tested during development and in production. Only 10BASE-T1S Ethernet interfaces that have passed compliance testing in line with IEEE 802.3cg can be deployed in vehicles. Consequently, vehicle manufacturers and their suppliers need measuring equipment that allows them to perform these tests quickly and reliably.
15-May-2020
Using VISA (Virtual Instrument Software Architecture) several interfaces allow communication between your computer and instruments. This application note describes the usage of both - R&S® VISA- NI VISA running on Microsoft Windows 10™ with the following connection types: ► USB VCP (Virtual Com Port), also called USB CDC (Communications Device Class) ► USB TMC (Test and Measurement Class)► Ethernet Raw Port Socket► Ethernet in general e.g. VXI11 or HislipAll the examples are shown using the R&S® HMC8042 unless otherwise stated. There may be some difference when integrating other devices. As example some interface types are not available on every unit.This application note does not claim to be complete. All information has been compiled with care. However, errors can’t be ruled out.
28-Oct-2021 | AN-No. 1SL374
Linking EDA design simulation and hardware testing to enable an easy, straightforward process flow and first-pass design.
16-Aug-2021
High-precision two-quadrant power supplies generate current profiles and simulate batteries
10-Dec-2020
Thanks to their multichannel capability, oscilloscopes are ideal for multichannel applications such as the analysis of MIMO signals (e.g. 5G NR, WLAN), multi-antenna radar signals and differential high-speed digital signals (e.g. USB 3.x). These applications require the oscilloscope channels to be tightly aligned. This means the channel-to-channel residual skew has to be measured accurately so that it can be compensated. The channel-to-channel phase mismatch is reduced to a minimum, which plays a crucial role in achieving reliable measurement results.
06-May-2020
In civil aviation, instrument landing system (ILS) transmitters use antenna arrays to provide guidance to approaching aircraft. ILS performance strongly depends on the precise alignment of the magnitude and phase of each element in an antenna array. The R&S®ZNH handheld vector network analyzer with a built-in source allows fast, convenient on-site measurements on the ILS antenna system.
09-Aug-2021
Antennas have become an integral part of consumer electronics, even in small portable devices that rely on an energy source with limited capacity. Consequently, antennas need to be physically small and power efficient.
05-Mar-2020
Frequency converters e.g. in satellite transponders need to be characterized not only in terms of amplitude transmission but also in terms of phase transmission or group delay, especially with the transition to digital modulation schemes. They often do not provide access to the internal local oscillators. This application note describes a method using the R&S®ZNA analyzer family to measure group delay of mixers and frequency converters with an embedded local oscillator very accurately. The key aspect of this new technique is that the network analyzer applies a 2-tone signal to the frequency converter. By measuring the phase differences between the two signals at the input and at the output, it calculates group delay and relative phase.
11-Jul-2019 | AN-No. 1EZ81
Synthetic aperture radar (SAR) uses radar wavelengths for airborne or spaceborne ground mapping. The resolution of the SAR ground map depends on the range and cross-range SAR processing resolution. Cross-range resolution is determined by integrating pulses along a flight path for a period of time to create a synthetic aperture. Longer synthetic apertures result in finer cross-range resolution. Range resolution is achieved by radar waveform bandwidth in the form of a linear frequency modulated (LFM) chirp. Wider bandwidth enables finer range resolution.
16-Apr-2021
With its small footprint, the R&S®ATS1000 antenna test system is the ideal direct far-field OTA system to test phased array antennas. The system tests and optimizes the radiation characteristics of any modules using the AiP technology from 18 GHz to 87 GHz.
12-Mar-2020
In this day and age of internet of things, more and more devices are connected to the local network, making it even more difficult for the IT department to monitor them. Rohde & Schwarz instruments are also increasingly accessed via their LAN interface, which provides additional convenience features such as remote desktop, SMB file transfer or a web interface. To make it easier to monitor the use and status of instruments, some devices offer a software option, the Health and Utilization Monitoring Service (HUMS).HUMS can be accessed via SNMP and REST (HTTP) and provides all necessary information about the health status and utilization over time in many details.This application note describes how to access HUMS and what data is provided.
11-Jan-2021 | AN-No. GFM336