Filter by Content
  • Applications 49
  • Firmware 17
  • Manuals 5
  • Documents & articles 4
  • Software 2
  • Drivers 1
Website Content 7

Website Content

Find more relevant information about our Products and Solutions.

78 Results

Relevance

Firmware for R&S®ZVx Vector Network Analyzer Family

Title Versions Last Modified File Size Vector Network Analyzer Family ZVx - Firmware V.3.52 This Version is only for ZVM/ZVK and for ZVRx/ZVCx running under Windows NT ! (Please copy all files into an empty folder on your PC. Disk1.bin contains the files for Disk 1. Follow the instruction in one of the release notes. You need 5 formatted 3.5" disks.)

Drivers for R&S®ZVx Vector Network Analyzer Family

File DescriptionDateDriver rszv (4.3.4) history 17.11.2014 Driver NameSizeVersionDateLabVIEW 7.1 Driver rszv 3 MB4.3.4, 11/2014 17.11.2014 VXIplug&play x86 Driver rszv 1 MB4.3.4, 06/2003 13.06.2003 LabWindows/CVI Driver rszv 187 kB4.3.4 06/2003 13.06.2003 5. October 2004 History and release notes for ZVB Rohde & Schwarz 1 History and release notes for the Rohde&Schwarz Vector Network Analyzers ZVR

Transfer of Trace Data from R&S Network Analyzer ZVx to Microsoft Excel

This application note describes how to directly transfer S-Parameter Trace Data from R&S Network Analyzers to Microsoft Excel using a direct connection like GPIB or LAN. Prerequisites are a PC running Microsoft Excel, a R&S Network analyzer like ZVA, ZVB or ZVT as well as a working remote control connection between PC and instrument like GPIB or LAN / Ethernet.

22-Mar-2007 | AN-No. RSI02

S-Parameters of a 50 to 75 Ohm impedance matching device using R&S®ZVx VNA

This document describes how the advanced calibration techniques of the ZVA Vector Network Analyzers can solve the challenges of measuring the S-Parameters on impedance matching devices. The document describes the concept and setup required to perform the calibration of the ZVA and making the measurement. The procedure described in this application note applies to the ZVB and ZVT Vector Network Analyzers as well.

06-May-2009 | AN-No. 1EZ59

Antenna Array Testing - Conducted and Over the Air: The Way to 5G

5G networks will need to offer more capacity and flexibility while lowering the operational expenses of the system. Two new technologies can simultaneously address both the increase in capacity and the increase in energy efficiency: Virtualization & Massive MIMO. This white paper provides an overview of test solutions addressing current and future requirements for antenna verification including both conducted and over-the-air (OTA) test methods, which result from applying Massive MIMO antenna technology.This white papers complements the white paper (1MA276) from Rohde & Schwarz, which introduces fundamental theory behind beamforming antennas and provides calculation methods for radiation patterns, a number of simulation results as well as some real world measurement results for small linear arrays.

11-Nov-2016 | AN-No. 1MA286

Interchangeable Port Connector System, Test Port Adapter System

A Test Port Adapter System is implemented for all Rohde & Schwarz equipment, which operates above 26 GHz in order to protect the RF front-end from mechanical damage. The Test Port Adapter System consists of an RF front-end interface called the Test Port Adapter Body, and the Test Port Adapter Head which is attached to the Body. The Head provides an interface to a cable or device under test. This Application Note identifies the various types of Test Port Adapters, their parameters, compatibilities and usages.

28-Apr-2015 | AN-No. 1MA100

Internal Data Transfer between Windows 3.1 / Excel and Vector Network Analyzer ZVR

This Application Note describes the internal transfer of ZVR measurement data in Excel, carried out on the PC option of the ZVR, and the evaluation of the data in Excel tables. To start the data transfers, macros are implemented under Excel.

28-Jul-1998 | AN-No. 1EZ39

Performing Amplifier Measurements with the Vector Network Analyzer ZVB

This document describes typical measurements that are required to be made on amplifiers and how the measurement can be implemented on the ZVB Vector Network Analyzer. The document describes the concepts and setups required to perform Gain, Isolation, input impedance measurements, then goes on to describe how more uncommon measurements are made with the ZVB like Harmonics, Stability Factor and compression point.

07-Feb-2007 | AN-No. 1EZ54

Power Calibration of Vector Network Analyzer R&S®ZVR

The option ZVR-B7 allows an enhanced power calibration of the source and of the receiver channels of a ZVR, then being active instead of the standard factory power calibration. Using an external power meter, the power level of input or output wave quantities will be adjusted to a desired value at an arbitrary reference plane.

29-Jul-1998 | AN-No. 1EZ41

Virtual Embedding Networks for R&S®ZVR and R&S®ZVC Network Analyzers

Embedding and De-Embedding of virtual transformation networks for measuring scattering parameters with a ZVR or ZVC vector network analyzer.

25-Sep-1998 | AN-No. 1EZ45

Time Domain Measurements using Vector Network Analyzer R&S®ZVR

Vector Network Analyzers of the ZVR family measure magnitude and phase of complex S-parameters of a device under test (DUT) in the frequency domain. Using an inverse Fourier transform, the results can be transformed to the time domain. The impulse or step response of the DUT is obtained, which gives an especially clear representation of its characteristics. For instance, faults in cables can be directly localized. Moreover, special time domain filters, so-called gates, can be used to suppress unwanted signal components such as multireflections.

04-Aug-1998 | AN-No. 1EZ44

Conversion Calculator for Power Units and VSWR/Reflection

This Application Note describes two programs for calculating conversions: 1.: The Power Unit Calculator Power, dBm, dBmV and Volts @ 50 W 2.: The VSWR Calculator Reflection, VSWR, Return loss and Power reflection Reflections, Reflectionl to Mismatch Uncertainty.

03-Jul-1998 | AN-No. 1MA12

3-Port Measurements with Vector Network Analyzer R&S®ZVR

3-Port Adapter ZVR-B8 is an optional accessory to all Vector Network Analyzers of the ZVR family, namely ZVRL, ZVRE, and ZVR, and extends the two test ports PORT1 and PORT2 to a total of three test ports PORT1, PORT2 and PORT3. The option comprises an electronic single-pole double-throw switch (SPDT) by means of which PORT1 of the analyzer is switched to either PORT1 or PORT3 of 3-Port Adapter. Test port PORT2 of the analyzer is directly connected to PORT2 of the 3-Port Adapter and is not switched over.

04-Aug-1998 | AN-No. 1EZ26

Measurement Accuracy of the R&S®ZVK Vector Network Analyzer

Measurement deviations due to systematic errors of a network analysis system can be drastically reduced by an appropriate system error calibration. After system error correction, the residual measurement uncertainties are - besides the stability, linearity, and dynamic range of the network analyzer system - mainly affected by the quality of the calibration standards and the repeatability of the connections. The effective measurement accuracy of the network analysis system can be determined using the results of successive verification measurements utilizing highly precise verification standards.

24-Jan-2001 | AN-No. 1EZ48

Producing Epicycloid Traces

This is a very special application note for all those who have seen the ZVatch (ZVR watch) and not really believed the nice red curve on its face. This curve can actually be generated with a Vector Network Analyzer ZVR.

25-Jan-2002 | AN-No. 1EZ28

Antenna Measurements, RCS Measurements and Measurements on Pulsed Signals with Vector Network Analyzers R&S®ZVM, R&S®ZVK

This application note describes the suitability of the R&S®ZVM and R&S®ZVK as multichannel microwave receivers for antenna measurements and RCS measurements including measurements on pulsed signals. Application examples describe the measurement possibilities on pulsed signals using the R&S®ZVM/ZVK as stand-alone units. In addition, various R&S®ZVM/ZVK-based antenna measurement systems of the March Microwave company are presented in detail.

10-Sep-2004 | AN-No. 1EZ52

Pulsed Measurements on GSM Amplifier SMD ICs with Vector Network Analyzer R&S®ZVR

A special requirement for testing GSM components is to measure the electrical characteristics, such as the gain of a power amplifier, of the DUT under pulsed conditions. The test should be similar to real operating conditions for a mobile telephone.

28-Jul-1998 | AN-No. 1EZ42

T-Check Accuracy Test for Vector Network Analyzers utilizing a Tee-junction

The measurement accuracy of vector network analyzers can be tested simply, easily and quickly, with a simple DUT which consists of a common tee-junction with one port, terminated with a resistive load Z, and the T-Check program. The four S-parameters from ports 1 and 2 are measured with the vector network analyzer to be checked and then evaluated by means of the T-Check software.

04-Aug-1998 | AN-No. 1EZ43

Group and Phase Delay Measurements with Vector Network Analyzer ZVR

Using a Vector Network Analyzer from the ZVR family, not only magnitude and phase can be measured, but also group delay and even phase delay. Whereas phase delay measurements produce the highest accuracy for the electrical length of non-dispersive devices under test, such as coaxial cables, group delay measurements also give a detailed insight into the frequency dependent delay characteristics of dispersive devices, such as filters. In addition to the traditional step aperture technique, Vector Network Analyzers from the ZVR family offer a frequency aperture technique, which allows a well defined and constant aperture for group delay measurements also for a nonlinear frequency sweep.

28-Jul-1998 | AN-No. 1EZ35

Remote Operation of R&S Instruments Using Remote Desktop Connection via LAN

Rohde & Schwarz instruments can be shared when users wish to use the same instrument. This can be done quite easily with the LAN interface, which comes as a standard option. Through this interface, Rohde & Schwarz instruments can be connected directly to a network, and users with access to the network can manually operate the instrument from a remote computer. This Application Note lists all instruments that support these features and describes the steps necessary to set up and configure the network connection to operate these instruments remotely.

05-Jul-2007 | AN-No. RAC-0703-0029

R&S®ZVRx, R&S®ZVCx, R&S®ZVM, R&S®ZVK Operating Manual

Describes all instrument functions and remote control commands, including measurement and programming examples, for the base unit. Also describes some general functions that apply to several applications.

Measurement of Dielectric Material Properties

This application note describes the techniques to measure the dielectric properties of materials using a vector network analyzer. It also shows methods for converting the s-parameters to dielectric properties.

23-May-2012 | AN-No. RAC-0607-0019

GPIBShot - Taking Screenshots via IEEE Bus

Application note 1MA25 has been replaced by application note .

28-Aug-2009 | AN-No. 1MA25

Remote Control of R&S Spectrum and Network Analyzers via LAN

Spectrum and network analyzers equipped with network interface cards can be integrated in Local Area Networks (LAN). This Application Note describes how to remote control these instruments over a LAN and use VXIpnp instrument drivers over a LAN.

25-Jun-2003 | AN-No. 1EF47

Using the Frequency Conversion Mode of the R&S®ZVR Vector Network Analyzer

Using option ZVR-B4 (Frequency Converting Measurements), a ZVR Vector Network Analyzer can be used for measurements on frequency converting devices such as mixers and amplifiers. Using the ZVR's ARBITRARY mode, the source and receiver frequency ranges of the ZVR's generator and receiver, plus for two external signal generators, can be defined independently. As a result, mixer and intermodulation products such as conversion loss or sampling mixers, can all be measured. Used together with option ZVR-B6 (Reference Channel Ports), group delay measurements can also be made on frequency converting devices.

19-Jan-1999 | AN-No. 1EZ47

4-Port Measurements with Vector Network Analyzer R&S®ZVR

Three hardware modifications of the option External Measurements ZVR-B25 enable the bidirectional network analyzers of the ZVR-family to carry out 4-port measurements. For the measurements, the four ports PORT 1, PORT 2, INPUT b1 and INPUT b2 at the front panel of the ZVR(E) are utilized. The fifth connector, ie OUTPUT a1, is not required for this purpose. As detailed below, the necessary modifications of the test set of the analyzer are described for the model ZVR. Of course, the modifications can be done in a similar way for the model ZVRE as well.

28-Jul-1998 | AN-No. 1EZ25

Conversion Gain Measurements on Mixers with Different Input and Output Impedances

This Application Note describes how to configure and calibrate R&S ZVR network analyzers for conversion gain measurements of devices with two ports that have different impedances. Thus accurate measurements on frequency-converting devices such as low noise converters of sattellite receivers are possible.

16-May-2002 | AN-No. 1EZ50

Rohde & Schwarz Drivers under VEE - Installation and Troubleshooting

The use of Rohde & Schwarz device drivers under VEE software is not complicated. However, a number of factors are involved, the errors that occur are often difficult to diagnose. This application provides easy and detailed support for installation and troubleshooting using National Instruments or Agilent GPIB boards.

20-Dec-2012 | AN-No. 1MA035

AutoCal: Automatic Calibration of Vector Network Analyzer ZVR

Vector network analyzers are used in high frequency applications to measure the complex scattering parameters of an unknown device-under-test (DUT). In general, the DUT characteristics can be evaluated by using electromagnetic waves. The correlation between the incident, reflected and transmitted wave quantities at the DUT is defined by its scattering matrix S.

28-Jul-1998 | AN-No. 1EZ30

Using MATLAB for Remote Control and Data Capture with R&S Spectrum and Network Analyzers

Spectrum and network analyzers are capable of measuring large amounts of data that require complex mathematical processing; MATLAB is a powerful tool for such operations. This application note describes how instruments can be controlled directly from MATLAB scripts and how measurement data can be imported into MATLAB. Only 32-bit MATLAB is supported.

24-Sep-2007 | AN-No. 1EF46

  • 1
  • 2
  • 3
Results 1 - 30 of 78
background
Facebook
YouTube
RSS Feeds
LinkedIn
Twitter
Rohde & Schwarz Danmark A/S

For nearly 80 years, Rohde & Schwarz has stood for quality, precision and innovation in all fields of wireless communications.

Address

Rohde & Schwarz Danmark A/S

Lyskær 3D, 1., DK-2730 Herlev, Denmark

Contact

+45 4343 6699

info.rsdk@rohde-schwarz.com

© 2021 Rohde & Schwarz

  • Cookie Information
  • Imprint
  • Statement of privacy
  • Jobs & Career
  • Terms of website use