Key facts

  • 4 channels with 0 to ±10 V, 0 to ±500 mA, sink-enabled output
  • Minimum resolution 10 µV/10 pA (measurement)
  • DC, pulse, sweep and pulse sweep operation; min. 50 µs pulse width
  • Synchronous operation of channels and multiple units
  • 6541 benchtop unit with color LCD monitor

4-channel compact source monitor capable of synchronous measurements among channels

The low-noise 6540/6541 units integrate multiple channels. They can be used as a power supply for devices and simultaneously as a load, allowing pulse generation of the minimum pulse width of 50 µs, sweep operation and synchronous operation among multiple channels or units. The source and measurement range is 0 to ±10 V for voltage and 0 to ±500 mA for current. They both have a USB interface.

Features & benefits

Synchronous source and measurement

4-channel synchronous operation

The 6540/6541 can synchronize measurements in the DC source mode, and sources and measurements in the pulse source and sweep source modes. Even different waveforms can be generated and measured.
Arbitrary master channel and slave channels are selectable. Up to 3 units can be synchronized, so that up to 12 channels can be operated in sync (3 x 4 channels = 12 channels). 

6540/6541 4-channel DC generator/monitor
Open Lightbox

Synchronized operation in different operating modes

Suspend function

Suspend function with HiZ and LoZ output impedance selection

The 6540/6541 can select from three output OFF statuses; STBY (output relay OFF), HiZ (output relay ON and high resistance) and LoZ (output relay ON and low resistance). This means unnecessary relay ON/OFF operations can be eliminated, which can increase product reliability.
In addition, the setting of a suspend voltage (voltage in HiZ and LoZ status) can prevent unwanted leakage currents when connected to voltage sourcing devices such as batteries.

6540/6541 4-channel DC generator/monitor
Open Lightbox

Different output status settings

Application-adapted current mesaurements

Peak/average current determination using well adapted, arbitrary setting integration time

A precise average current measurement has to measure all current passing during a specific DUT operating mode.
The 6540/6541 are capable of accurate average current measurements by measuring the peak current and using the variable integration function (arbitrary setting from 100 µs to 740 ms). This makes it easy to measure the average current consumption of mobile devices.  The peak hold measurement function detects and measures maximum values up to 20 kHz pulses.

6540/6541 4-channel DC generator/monitor
Open Lightbox

Peak and average current measurements

Variable setting integration times for optimal adaptation to DUT's operating modes

Separate HI/LO limiter setting

The limiter function is important for voltage or current sourcing to protect the connected devices. The current limiter works for the voltage source to restrict output current and the voltage limiter works for the current source to restrict output voltage. The 6540/6541 have two setting levels that can be set separately for both voltage and current limiters. The separate setting capability can prevent overdischarge conditions at batteries or reverse voltage conditions at laser diodes and capacitors.

6540/6541 4-channel DC generator/monitor
Open Lightbox

Non-symmetric limiter setting capability

Conventional (symmetric) limiter settings (dotted line for LOVL) can cause critical reverse polarity conditions at DUTs, e.g. at charging devices.

Internal source and measurement buffer

10 000 cell buffer for source and measurement per channel

All four channels are equipped with an internal 10 000 sample memory and 10 000 random sweep memory, allowing fast data aquisition or fast waveform generation without the need for remote control interaction. They can be triggered and synchronized by external signals or commands.

6540/6541 4-channel DC generator/monitor
Open Lightbox

Sweep and measurement memory

Output response adaptation

Low-noise source combined with fast response time

The 6540/6541 series is based on a linear operation concept. This enables not only fast response times on load changes, but also excellent low noise output supply with predictable regulation characteristics. Depending on application needs, the user can select between low or fast response behavior. Its low  range-switching noise allows high-resolution sweeps crossing multiple ranges.

6541 with 4.3 inch color display

Convenient, intuitive operation with different levels of information

The  6541 offers view settings tailored to particular needs: 4-channel overview view or 1-channel detailed setting view. Even the time-wise behavior of each channel can be easily visualized on the display. In addition, an extensive, self-explanatory menu concept provides access to parameter settings. Different colors indicate the channel assignments.

6540/6541 4-channel DC generator/monitor
Open Lightbox

1-channel view, 4-channel view, time setting view

Available models


  • Product Name

    6540

    Order number 3651.9422.02

    Color LCD display
     
    USB interface
    GPIB interface
     
    LAN interface
     
  • Product Name

    6541

    Order number 3651.9439.02

    Color LCD display
    USB interface
    GPIB interface
     
    LAN interface
     
  • Product Name

    6541+01

    Order number 3651.9445.02

    Color LCD display
    USB interface
    GPIB interface
    LAN interface
     
  • Product Name

    6541+06

    Order number 3651.9451.02

    Color LCD display
    USB interface
    GPIB interface
     
    LAN interface
  • Product Name

    6541+01+06

    Order number 3651.9468.02

    Color LCD display
    USB interface
    GPIB interface
    LAN interface

Solicitar información

¿Tiene preguntas o necesita información adicional? Simplemente complete este formulario y nos pondremos en contacto con usted.

Permiso de marketing

Deseo recibir información de Rohde & Schwarz por

¿Qué significa esto exactamente?

Estoy de acuerdo con que ROHDE & SCHWARZ GmbH & Co. KG y la entidad o subsidiaria ROHDE & SCHWARZ que figure en la Declaración de confidencialidad del sitio web se ponga en contacto conmigo a través del canal elegido (correo electrónico o correo postal) para fines de marketing y publicitarios (p. ej., información sobre ofertas especiales y promociones de descuentos) en relación con, pero sin limitarse a, productos y soluciones para test y medida, seguridad en las comunicaciones, monitorización y medidas de redes, broadcast y multimedia así como ciberseguridad.

Sus derechos

Esta declaración de consentimiento se puede retirar en cualquier momento enviando un correo electrónico a news@rohde-schwarz.com con el asunto «Cancelar mi suscripción». Además, en cada correo electrónico enviado se incluye un enlace para cancelar por correo electrónico la suscripción a futuros anuncios. En la Declaración de privacidad encontrará información adicional sobre el uso de los datos personales y el procedimiento de retirada.

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.