R&S®SCQ8000 L-Band Transmitters

Key Facts

  • Compact and cost-effective transmitter family offering all the quality and performance that Rohde & Schwarz stands for
  • Innovative redundancy concepts for economical use of available space
  • High efficiency for reduced energy costs

Brief Description

The R&S®SCQ8000 and R&S®SCL8000 transmitters expand the successful R&S®SCx8000 family of transmitters to include a compact solution for the L-band frequency range.

Specifications

Frequency range Power supply
L band / 1452 MHz to 1492 MHz AC / 208 V to 240 V ± 10%, 47 Hz to 63 Hz

Key Facts

  • Compact and cost-effective transmitter family offering all the quality and performance that Rohde & Schwarz stands for
  • Innovative redundancy concepts for economical use of available space
  • High efficiency for reduced energy costs
  • Fast startup and easy operation

Brief Description

The R&S®SCQ8000 and R&S®SCL8000 transmitters expand the successful R&S®SCx8000 family of transmitters to include a compact solution for the L-band frequency range. They enable network operators to quickly expand or set up transmitter networks for DVB-T, DVB-H and MediaFLO as well as DAB, DAB+ and T-DMB. The transmitters offer an efficiency of up to 18 % for TV and up to 22 % for DAB, which is unparalleled in this power class.

Specifications

Frequency range L band 1452 MHz to 1492 MHz
Available standards digital TV DVB-T, DVB-H, MediaFLO
digital audio broadcasting DAB, DAB+, T-DMB
Power supply AC 208 V to 240 V ± 10 %, 47 Hz to 63 Hz
Synchronization
Reference frequency 10 MHz, –5 dBm to +20 dBm or LVT, BNC
Reference pulse 1 pps (1 Hz, TTL, BNC)
Operation
Display, keypad and status LEDs local operation and display
Ethernet interface, RJ-45 convenient local or remote control via standard web browser
Environmental conditions
Max. installation height 2000 m (6560 ft) above sea level
(>2000 m/6560 ft on request)
Operating temperature range +1 °C to +45 °C
Relative humidity (max.) 95 %, non-condensing
Electromagnetic immunity
Fast transients and bursts in line with IEC 61000-4-4 power feed < 2 kV
signal inputs < 1 kV
Surges in line with IEC 61000-4-5 symmetrical < 1 kV (e.g. L1-L2, L-N)
unsymmetrical < 2 kV (e.g. L-PE, N-PE)
If a higher electromagnetic immunity is required for transmitter operation, appropriate protective measures must be taken. Rohde & Schwarz offers options for overvoltage and lightning protection.
RF output R&S®SCQ/L8301x 7-16
R&S®SCQ/L8304x EIA 7/8"
Dimensions (W × H × D) R&S®SCQ/L8301E 483 mm × 178 mm × 550 mm (19", 4 HU)
(19 in × 7 in × 21.7 in)
R&S®SCQ/L8301R 483 mm × 222 mm × 550 mm (19", 5 HU)
(19 in × 8.7 in × 21.7 in)
R&S®SCQ/L8304E 600 mm × 2000 mm × 800 mm
(23.6 in × 78.7 in × 31.5 in)
R&S®SCQ/L8304V 600 mm × 2000 mm × 800 mm
(23.6 in × 78.7 in × 31.5 in)
Important:

To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.

Gracias.

La solicitud se ha enviado correctamente.

En breve nos pondremos en contacto con usted.

Su equipo de servicio Rohde & Schwarz

Solicitar presupuesto

Introduzca su consulta.
Introduzca su nombre.
Introduzca el nombre.
Introduzca una dirección de correo electrónico válida.
Introduzca el nombre de la empresa.
Introduzca el nombre de la ciudad.
Introduzca el código postal.
Introduzca el número de teléfono.

Introduzca el país.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Introduzca los caracteres que se muestran en la imagen
show captcha
Datos incorrectos.
Do not enter data in this field
Gracias.

La solicitud se ha enviado correctamente.

En breve nos pondremos en contacto con usted.

Su equipo de servicio Rohde & Schwarz

Solicitar información

Introduzca su consulta.
Introduzca su nombre.
Introduzca el nombre.
Introduzca una dirección de correo electrónico válida.
Introduzca el nombre de la empresa.
Introduzca el nombre de la ciudad.
Introduzca el código postal.

Introduzca el país.
Marketing permission

I want to receive information from Rohde & Schwarz via


What does this mean in detail?

"I agree that ROHDE & SCHWARZ GmbH & Co. KG and
a) ROHDE & SCHWARZ Vertriebs-GmbH (for Germany) or  
b) the ROHDE & SCHWARZ entity in the imprint of this website (for any other country) 
may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity."

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the “Statement of Privacy“.

Introduzca los caracteres que se muestran en la imagen
show captcha
Datos incorrectos.
Do not enter data in this field
International Website