R&S®SFD DOCSIS signal generator

Single channel DOCSIS 3.1 in realtime

R&S®SFD DOCSIS signal generator
Abrir Lightbox
R&S®SFD DOCSIS signal generator
Abrir Lightbox
R&S®SFD DOCSIS signal generator
Abrir Lightbox
R&S®SFD DOCSIS signal generator
Abrir Lightbox
R&S®SFD DOCSIS signal generator
Abrir Lightbox
R&S®SFD DOCSIS signal generator
Abrir Lightbox
R&S®SFD DOCSIS signal generator, Front view R&S®SFD DOCSIS signal generator, Front High R&S®SFD DOCSIS signal generator, Side view R&S®SFD DOCSIS signal generator, Back view R&S®SFD DOCSIS signal generator, Hero view R&S®SFD DOCSIS signal generator, Application Image

Key Facts

  • Downstream: 47 MHz to 1218 MHz/1794 MHz, Upstream: 5 MHz to 204 MHz
  • DOCSIS3.1, DOCSIS3.0, J.83/A/B/C and analog TV
  • Signal interference and distortion simulation
  • Simultaneous generation of at least 80 SC-QAM channels between 1002 to 1794 MHz
  • ARB generator bandwidth up to 200 MHz

DOCSIS 3.1 single channel realtime generator

The R&S®SFD generates a DOCSIS 3.1 channel in realtime with flexible setting of the level, frequency, constellation and all other parameters according the DOCSIS 3.1 standard. The R&S®SFD can alternatively generate a digital realtime modulated TV signal according the J83A/B/C specification. The content can be fed in via IP or internally generated by the R&S®SFD.

Features & benefits

Signal generation in the downstream

Flexible realtime downstream modulation

The R&S®SFD modulates signals for DOCSIS 3.1, DOCSIS 3.0, digital cable TV in line with J.83/A/B/C in real time. Its downstream frequency range is 47 MHz to 1794 MHz for DOCSIS 3.1 and 47 MHz to 1218 MHz for DOCSIS 3.0 and digtal TV. All parameters can be set via GUI or via SCPI remote commands. The user data to be transmitted can be fed in via IP or internally generated by the R&S®SFD from PRBS or an user file. The SFD-K202 option allows the simultaneous generation of at least 80 SC-QAM channels in the extended operating range of 1002 to 1794 MHz.

R&S®SFD GUI - Downstream configuration
Abrir Lightbox

R&S®SFD GUI - Downstream configuration

Easy to use GUI allows the setup of the downstream signal with all required parameters. Predefinded values speed up the time to the first results.

Signal generation in the upstream

Flexible realtime upstream modulation

The upstream frequency range is 5 MHz to 204 MHz. Within this range, a DOCSIS 3.1 orthogonal frequency division multiple access (OFDMA) signal can be generated in realtime. A DOCSIS 3.0 TDMA or CDMA signal can be produced in realtime in the 5 MHz to 85 MHz range. The trigger function allows precise burst timing control. The R&S®SFD is an ideal solution for testing tuners, cable modems and upstream CMTS receivers.

R&S®SFD GUI - Upstream configuration
Abrir Lightbox

R&S®SFD GUI - Upstream configuration

Easy to use GUI allows the setup of the upstream signal with all required parameters. Predefinded values speed up the time to the first results.

Signal interference and distortion simulation

Simulate realistic receive conditions

For realistic signal generation, the R&S®SFD can add interference such as noise, phase noise, hum, tilt and even a defined bit error rate (BER). The signal tilt can be set positive or negative for simulation or compensation of the frequency response of a real coax CATV cable.

R&S®SFD GUI - Impairments configuration
Abrir Lightbox

R&S®SFD GUI - Impairments configuration

The impairments settings can be mixed and set independed. RF tilt settings (dB/GHz) are set on the home GUI section.

Powerful ARB generator

The integrated ARB generator can generate up to 200 MHz wide signals and is usable in the entire downstream or upstream frequency range. The maximum sample rate is 240 Msamples/s and the ARB file size up to 256 Mbyte.

R&S®SFD GUI - ARB files
Abrir Lightbox

R&S®SFD GUI - ARB files

The most popular signals from worldwide CATV networks can be modulated with the ARB files. The factory files can be extended by user files.

Available options

Software options
Product
Descripción
R&S®SFD-K200

Order Number 2118.7423.02

Descripción

Downstream Generator

DOCSIS 3.1/3.0, J.83/A/B/C, downstream modulation, 47 MHz to 1218 MHz

R&S®SFD-K201

Order Number 2118.7830.02

Descripción

Enhanced Downstream Functions

Insertion of DOCSIS timestamps in downstream PLC, flow rate indicator and additional transmission of DPD messages for profiles B, C and D on the PLC (FSW compatibility mode)

R&S®SFD-K202

Order Number 2118.8242.02

Descripción

Extended Spectrum Multi-Carrier SC-QAM

DOCSIS 4.0 FDD Multi-Carrier SC-QAM Generation J.83A/B, 1002 to 1794 MHZ 

R&S®SFD-K300

Order Number 2118.7430.02

Descripción

Upstream Generator

DOCSIS 3.1 and 3.0, upstream modulation, 5 MHz to 204 MHz

R&S®SFD-K3018

Order Number 2118.7452.02

Descripción

Downstream Frequency Range Extension to 1794 MHz

R&S®SFD-K1050

Order Number 2118.7446.02

Descripción

Signal Interference Simulation

Interferer simulation, AWGN, phase noise, AC hum, defined BER

R&S®CLGD-K2

Order Number 2118.7469.02

Descripción

Basic Waveform Library

Bundle of frequently used waveforms

General accessories
Product
Descripción
R&S®ZZA-KNA22

Order Number 1177.8184.00

Descripción

19" Adapter BW2010-ADV, 2HU 1/2 + Spare

R&S®ZZA-KNA24

Order Number 1177.8149.00

Descripción

19" Adapter BW2010 Advanced, Cabinet 2HU 1/2 + ½

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Permiso de marketing

Se ha enviado su solicitud. Nos pondremos en contacto con usted lo antes posible.
An error is occurred, please try it again later.
Información general y jurídica

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Términos y condiciones del sorteo de premios con motivo del 10° aniversario de los osciloscopios de Rohde & Schwarz

1. El sorteo «10 años de osciloscopios de Rohde & Schwarz» (en adelante el «sorteo») está organizado por Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Múnich, Alemania, tel. +49 89 41 29 0 (en adelante «R&S»).

2. Todos los participantes pueden inscribirse en el sorteo entre el 1 de enero de 2020 y el 31 de diciembre de 2020 indicando su nombre, el nombre de su compañía y la dirección de correo electrónico empresarial.

3. La participación es gratuita y no está vinculada a la compra de bienes o servicios.

4. El sorteo está destinado únicamente a personas jurídicas, y solamente las personas jurídicas tienen facultad para recibir los premios. No está permitida la participación de una persona individual en su propio nombre y cuenta, sino que deberá hacerlo como representante de una persona jurídica rellenando el formulario de participación en nombre y por cuenta de dicha persona jurídica.

5. Los participantes pueden ganar uno de los 10 R&S®RTB2000 sorteados en el periodo entre el 1 de enero de 2020 y el 31 de diciembre de 2020:

Premio: 1 osciloscopio digital R&S®RTB2000

6. El sorteo se celebra en la sede central de R&S, Muehldorstrasse 15, 81671 Múnich (Alemania). Los ganadores de los premios serán informados por correo electrónico en un plazo de cinco (5) días laborables.

7. El representante autorizado de la persona jurídica deberá notificar a R&S que acepta el premio. En caso de denegar la aceptación o de no obtenerse respuesta en un plazo de dos (2) semanas, se sorteará un nuevo ganador. Si no puede determinarse un ganador en un espacio de cuatro (4) semanas, el sorteo se dará por finalizado y el premio se dará por perdido.

8. Los empleados de R&S, sus familiares, así como cualquier persona que esté implicada en el proceso del sorteo y sus familiares quedan excluidos de rellenar el formulario de participación.

9. No está permitido abonar el equivalente en metálico ni intercambiar los premios. Los premios son intransferibles. Todos los impuestos, gravámenes, tasas de aduana, cuotas y otros pagos exigidos en el país del participante correrán a cargo del participante.

10. Los datos personales se procesarán exclusivamente para los fines de este sorteo de premios y se eliminarán cuatro (4) semanas después de finalizar el mismo, salvo otro acuerdo.

11. R&S se reserva el derecho de descalificar del concurso a cualquier participante que no cumpla los presentes términos y condiciones. En estos casos, los premios también podrán retirarse con efecto retroactivo. En caso de retirarse un premio con efecto retroactivo como consecuencia del incumplimiento de los presentes términos y condiciones, el respectivo participante deberá devolverlo, corriendo con los gastos correspondientes, a la dirección de R&S indicada en el punto 1, y se sorteará un nuevo ganador.

12. Los participantes no tienen derecho a reclamar los premios de este sorteo, ni está previsto ningún recurso legal a este respecto.

13. El sorteo, y cualquier relación contractual que se derive del mismo entre R&S y el respectivo participante, se regirán e interpretarán según la legislación de Alemania, excluyendo todo recurso por conflictos de leyes. Los tribunales de Múnich, Alemania, tendrán la competencia exclusiva en caso de cualquier litigio relacionado directa o indirectamente con la participación en este concurso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.