Key Facts

  • Extension unit for the R&S®ZVA/ZVT network analyzer
  • For measurements of T/R modules, receivers, transceivers, power amplifiers
  • Base unit ready for high power measurements
  • R&S®ZVAX-TRM models up to 24/40/50/67 GHz
  • Flexible configuration for the required application
  • 3-year warranty extension

Extension unit for measurements on active components

Configurable signal conditioning for R&S®ZVA/ZVT

The configurable R&S®ZVAX‑TRM extension unit is used with an R&S®ZVA/R&S®ZVT network analyzer to provide signal conditioning for demanding measurements on active devices under test. For example, it allows measurements on pulsed signals or noise figure measurements on transmit/receive (T/R) modules. Together with an R&S®ZVA network analyzer, the R&S®ZVAX‑TRM provides customized test sets for applications up to 24/40/50/67 GHz (restrictions on some options for the 67 GHz model).

Caractéristiques & avantages

Configurable test system

Flexible characterization of T/R modules

The R&S®ZVAX‑TRM is an extension unit for the R&S®ZVA/ZVT. The configurable external box adds hardware components required for transmit/receive modules or high-power testing. The base unit has two ports, couplers, and path access loops. Modules can be added as needed: output pre-amplifiers, combiners, pulse modulators, receiver pre-amplifiers. Uncoupling the options from the VNA protects it and maintains  full RF performance for the base unit when measuring without the R&S®ZVAX-TRM.

Convenient control via a graphical user interface
Open Lightbox

Convenient control via a graphical user interface

Excellent performance

Excellent performance data for measurements on T/R modules

The T/R module characteristics can be measured in both directions, making bidirectional pulse measurements possible. High output power levels are standard, even with a fully configured R&S®ZVAX-TRM.

Compact solution with open architecture

Signal access points to integrate external components and instruments

Measuring power or pulse profile calls for different test setups. To meet these requirements, the R&S®ZVAX-TRM offers the following:

  • Access to generator path (e.g. connect external power amplifiers)
  • Access to receiver path (e.g. connect attenuators for power measurements or to output signal to an external instrument)
  • Access to reverence signal (e.g. to utilize automatic level control)

Open Lightbox

Customized configuration

Get what you need

The R&S®ZVAX-TRM extension unit in its base configuration supports high-power two-port measurements up to +43 dBm (pulsed signals) and can easily loop in external components.
For greater flexibility the R&S®ZVAX-TRM functions can be expanded with diverse options such as:

  • pulse modulators
  • low-noise preamplifiers
  • output amplifiers
  • combiners

Open Lightbox

Available models

Available models
Modèles
Frequency range

R&S®ZVAX-TRM24

Numéro de commande 1322.6500.24

Frequency range
24 GHz

R&S®ZVAX-TRM40

Numéro de commande 1322.6500.40

Frequency range
40 GHz

R&S®ZVAX-TRM50

Numéro de commande 1322.6500.50

Frequency range
50 GHz

R&S®ZVAX-TRM67

Numéro de commande 1322.6500.67

Frequency range
67 GHz

Available options

R&S®ZVAX-TRM24 extension unit
Produit
Désignation
R&S®ZVAX24B31

Numéro de commande 1322.7020.24

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 1

R&S®ZVAX24B32

Numéro de commande 1322.7036.24

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 2

R&S®ZVAX24B712

Numéro de commande 1322.6969.24

Désignation

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B73

Numéro de commande 1322.6975.24

Désignation

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX24B112

Numéro de commande 1322.6981.24

Désignation

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B134

Numéro de commande 1322.6998.24

Désignation

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at network analyzer port 3 and port 4 or at R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX24B213

Numéro de commande 1322.7007.24

Désignation

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX24B224

Numéro de commande 1322.7013.24

Désignation

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM40 extension unit
Produit
Désignation
R&S®ZVAX40B31

Numéro de commande 1322.7020.40

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 1

R&S®ZVAX40B32

Numéro de commande 1322.7036.40

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 2

R&S®ZVAX40B712

Numéro de commande 1322.6969.40

Désignation

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B73

Numéro de commande 1322.6975.40

Désignation

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX40B112

Numéro de commande 1322.6981.40

Désignation

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B134

Numéro de commande 1322.6998.40

Désignation

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX40B213

Numéro de commande 1322.7007.40

Désignation

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX40B224

Numéro de commande 1322.7013.40

Désignation

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM50 extension unit
Produit
Désignation
R&S®ZVAX50B31

Numéro de commande 1322.7020.50

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 1

R&S®ZVAX50B32

Numéro de commande 1322.7036.50

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 2

R&S®ZVAX50B712

Numéro de commande 1322.6969.50

Désignation

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B73

Numéro de commande 1322.6975.50

Désignation

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX50B112

Numéro de commande 1322.6981.50

Désignation

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B134

Numéro de commande 1322.6998.50

Désignation

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX50B213

Numéro de commande 1322.7007.50

Désignation

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX50B224

Numéro de commande 1322.7013.50

Désignation

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM67 extension unit
Produit
Désignation
R&S®ZVAX67B31

Numéro de commande 1322.7020.67

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 1

R&S®ZVAX67B32

Numéro de commande 1322.7036.67

Désignation

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 2

R&S®ZVAX67B712

Numéro de commande 1322.6969.67

Désignation

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B73

Numéro de commande 1322.6975.67

Désignation

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX67B112

Numéro de commande 1322.6981.67

Désignation

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B134

Numéro de commande 1322.6998.67

Désignation

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX67B213

Numéro de commande 1322.7007.67

Désignation

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX67B224

Numéro de commande 1322.7013.67

Désignation

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.