R&S®NRPM OTA power measurement solution

R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®NRPM OTA power measurement solution
Open Lightbox
R&S®NRPM OTA power measurement solution, application image R&S®NRPM OTA power measurement solution, application image R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front high R&S®NRPM OTA power measurement solution, front view R&S®NRPM OTA power measurement solution, front view

Key Facts

  • Frequency range from 18 GHz to 90 GHz
  • Extremely fast RX list mode
  • For 5G, WLAN IEEE 802.11ad and IEEE 802.11ay as well as automotive radar
  • Fully calibrated antenna module with integrated diode detector
  • Scalable to customer requirements

Designed for extremely accurate over-the-air (OTA) power measurements

The R&S®NRPM is a fully calibrated and individually scalable OTA power measurement solution for benchtop applications or in anechoic chambers. Covering a frequency range from 18 GHz to 90 GHz, it is perfect for over-the-air (OTA) beamforming verification in 5G, WLAN IEEE 802.11ad and IEEE 802.11ay and the calibration of transmit antenna output power.

Caractéristiques & avantages

Specified system uncertainty

Fully calibrated OTA power measurement system with specified system uncertainty

With conventional OTA systems, measurement uncertainty comes from frequency-dependent antenna gain, antenna patterns and mismatched RF components. By measuring power directly at the antenna, the R&S®NRPM solution avoids this problem because it does not need any additional RF components. Moreover, the antenna gain, antenna pattern and diode detector are calibrated together. The user does not need to make any complicated system calibrations.

OTA power measurement system
Open Lightbox

OTA power measurement system

Low-reflection antenna module

Low radar cross section avoids disturbing reflections

The R&S®NRPM-A90 and -A90D antenna modules have a very low radar cross section of typically < –26 dB/sm, putting them about 15 dB/sm below the value of a typical horn antenna. This makes them ideal for screened environments, due to the virtual absence of reflections.

R&S®NRPM-A90 low-reflection antenna module
Open Lightbox

R&S®NRPM-A90 low-reflection antenna module

Very high sensitivity

The R&S®NRPM OTA power measurement solution uses a highly sensitive diode detector integrated directly on the antenna

The R&S®NRPM-A90 and R&S®NRPM-A90D antenna modules can measure power down to -76 dBm. For example, a DUT with a transmit power of -10 dBm can be positioned at a distance of 1 m, and  the received power at the antenna module can still be precisely determined.

OTA power measurement solution, benchtop
Open Lightbox

OTA power measurement solution, benchtop

System calibration for OTA receiver tests

To test the DUT receiver, it is necessary to know the exact OTA transmitted power at the DUT. To calibrate this measurement setup, the R&S®NRPM-A90 antenna module is positioned at the DUT for the transmit power calibration of the signal generator. The calibration uses an R&S®NRPM-A90/A90D antenna module, which is later replaced with the DUT. The receive power of the DUT is precisely detected.

System calibration for OTA receiver tests
Open Lightbox

System calibration for OTA receiver tests

TX beamforming verification

Multiple R&S®NRPM-A90/A90D antenna modules are needed to test the beamforming function. If the antenna beam is directed at a specific antenna module, this module shows the highest power for all the antennas. Three antenna modules – arranged in a plane – are used to verify whether beamsteering in the horizontal plane properly functions. To test vertical beamforming, the R&S®NRPM-A90/A90D antenna modules must be arranged on at least two horizontal planes.

TX beamforming verification
Open Lightbox

TX beamforming verification

Specifications
R&S®NRPM-A90 single polarized antenna
Frequency range 18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
trace -63 dBm to -19 dBm
Rise/fall time 2.2 μs
Video bandwidth 220 kHz
Measurement uncertainty
18 GHz to 24 GHz absolute 0.68 dB to 0.81 dB
relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.49 dB to 0.66 dB
relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.50 dB to 0.72 dB
relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.58 dB to 0.83 dB
relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.61 dB to 0.91 dB
relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.69 dB to 0.97 dB
relative 0.05 dB to 0.09 dB
R&S®NRPM-A90D dual polarized antenna
Frequency range 18 GHz to 90 GHz
Power measurement range (frequency dependent) continuous average -76 dBm to -19 dBm
trace -63 dBm to -19 dBm
Rise/fall time 2.2 μs
Video bandwidth 220 kHz
Measurement uncertainty (measurement distance 1 m)
18 GHz to 24 GHz absolute 0.73 dB to 0.85 dB
relative 0.05 dB to 0.09 dB
> 24 GHz to 35 GHz absolute 0.55 dB to 0.71 dB
relative 0.05 dB to 0.09 dB
> 35 GHz to 57 GHz absolute 0.59 dB to 0.78 dB
relative 0.05 dB to 0.09 dB
> 57 GHz to 71 GHz absolute 0.68 dB to 0.90 dB
relative 0.05 dB to 0.09 dB
> 71 GHz to 81 GHz absolute 0.72 dB to 0.99 dB
relative 0.05 dB to 0.09 dB
> 81 GHz to 90 GHz absolute 0.87 dB to 1.10 dB
relative 0.05 dB to 0.09 dB

Available options

Antenna modules
Produit
Désignation
R&S®NRPM-A90

Numéro de commande 1426.7760.02

Désignation

Single-polarized antenna module

Fully calibrated, low-reflection, single-polarized Vivaldi antenna with an integrated diode detector for power
measurements.

R&S®NRPM-A90D

Numéro de commande 1426.7777.02

Désignation

Dual-polarized antenna module

Two low-reflection, single-polarized Vivaldi antennas with an integrated diode detector, precisely arranged in a right angle. This allows measurement in both polarization directions.

Sensor modules
Produit
Désignation
R&S®NRPM3

Numéro de commande 1425.8563.02

Désignation

Three-channel sensor module

R&S®NRPM3N

Numéro de commande 1425.8592.02

Désignation

Three Channel LAN Sensor Module

Interface for shielded RF test box
Produit
Désignation
R&S®NRPM-ZD3

Numéro de commande 1425.8786.02

Désignation

Filtered cable feedthrough

R&S®NRPM-ZKD3

Numéro de commande 1436.2984.02

Désignation

Interface cable

Interface for benchtop application
Produit
Désignation
R&S®NRPM-Z3

Numéro de commande 1426.7602.02

Désignation

Interface module

The R&S®NRPM-Z3 is directly plugged onto the R&S®NRPM3 three-channel sensor module and can host up to three R&S®NRPM-A90 antenna modules to avoid additional cables.

General accessories
Produit
Désignation
R&S®NRP-ZKU

Numéro de commande 1419.0658.02

Désignation

USB-A interface cable, length: 0.75 m

R&S®NRP-ZKU

Numéro de commande 1419.0658.03

Désignation

USB-A interface cable, length: 1.5 m

R&S®NRP-ZKU

Numéro de commande 1419.0658.04

Désignation

USB-A interface cable, length: 3 m

R&S®NRP-ZKU

Numéro de commande 1419.0658.05

Désignation

USB-A interface cable, length: 5 m

R&S®NRP-ZK6

Numéro de commande 1419.0664.02

Désignation

6-pole interface cable, length: 1.5 m

R&S®NRP-ZK6

Numéro de commande 1419.0664.03

Désignation

6-pole interface cable, length: 3 m

R&S®NRP-ZK6

Numéro de commande 1419.0664.04

Désignation

6-pole interface cable, length: 5 m

R&S®NRP-Z5

Numéro de commande 1146.7740.02

Désignation

USB sensor hub

R&S®NRP-Z5 can host up to 4 R&S®NRPxxS(N), R&S®NRPxxT(N), R&S®NRPxxA(N) or R&S®NRP-Z sensors. A professional trigger solution allows simultaneous internal and external triggering of all connected sensors.

R&S®NRPM-ZKT

Numéro de commande 1425.8857.02

Désignation

Trigger cable

Documentation
Produit
Désignation
R&S®DCV-1

Numéro de commande 0240.2187.06

Désignation

Documentation of calibration values

R&S®DCV-ZP

Numéro de commande 1173.6506.02

Désignation

Printout of DCV

Related videos

Comprendre les mesures de puissance sans fil

Cette vidéo fournit une brève description technique des mesures de puissance sans fil, et à quel niveau elles diffèrent des mesures de puissance conduites classiques.

mai 18, 2020

Utilisation du R&S®NRPM

Cette courte vidéo fournit une brève description du système de mesure de puissance sans fil R&S®NRPM.

mai 18, 2020

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.