Mixed signal option oscilloscope hardware

Oscilloscope hardware

Mixed signal option oscilloscope hardware
Open Lightbox
Mixed signal option oscilloscope hardware
Open Lightbox
Mixed signal option oscilloscope hardware
Open Lightbox
Mixed signal option oscilloscope hardware
Open Lightbox
Mixed signal option oscilloscope hardware, Application Image Mixed signal option oscilloscope hardware, Application Image Mixed signal option oscilloscope hardware, Front view Mixed signal option oscilloscope hardware, Screenshot

Key Facts

  • Easy upgrade of any Rohde & Schwarz oscilloscope to an MSO
  • Precision measurement: up to 5 Gsample/s sampling rate
  • Deep memory: acquire long signal sequences
  • Comprehensive processing and analysis functions
  • Analysis of serial protocols, even with digital channels
  • Multi-domain icon

Brief description

The R&S®B1 MSO options turns Rohde & Schwarz oscilloscopes into fast, precise and easy-to-use mixed signal oscilloscopes (MSO). Mixed signal oscilloscopes are hybrid test instruments that combine the measurement capabilities of digital oscilloscopes with the analysis capabilities of logic analyzers.

Caractéristiques & avantages

More signal details

More signal details thanks to high time resolution across the entire memory depth

With a sampling rate of 5 Gsample/s, the R&S®B1 option for the R&S®RTO, R&S®RTE and R&S®RTM oscilloscopes provides a maximum time resolution of 200 ps for the digital channels. This sampling rate is available across the entire memory depth. As a result, the MSO option is even capable of detecting critical events such as narrow, widely separated glitches.

The digital channels of the R&S®RTO oscilloscope operate with 200 ps resolution and can detect short glitches.
Open Lightbox

The digital channels of the R&S®RTO oscilloscope operate with 200 ps resolution and can detect short glitches.

Precise triggering on signal events

The digital channel resolution of 200 ps makes these channels a precise trigger source. The R&S®B1 offers numerous trigger types for debugging and analysis, such as edge, width, pattern and serial pattern. These triggers can be combined with holdoff conditions. For the trigger source, the user can select individual digital channels, bus signals or any logical combination of digital channels by applying logic operations such as AND, OR and XOR.

Select from a comprehensive list of trigger types for the digital channels.
Open Lightbox

Select from a comprehensive list of trigger types for the digital channels.

Fast fault finding

High acquisition and analysis rate for fast fault finding

Hardware-based signal processing of measured digital waveforms extends from acquisition and triggering to analysis functions such as cursor functions and measurements, and even includes the visualization of the results. Parallel processing of all measured digital signals allows an acquisition and analysis rate of max. 200 000 waveforms per second with the R&S®RTO and R&S®RTE oscilloscopes, ensuring that rare events are detected quickly and reliably.

Open Lightbox

Straightforward display of digital signals

The R&S®RTO and R&S®RTE oscilloscopes’ R&S®SmartGrid function facilitates placement of digital channels on the screen. The digital channel activity remains visible in the signal icons irrespective of the acquisition state. The binary signals from the individual digital channels obtained between two screen dumps are superimposed in the measurement diagram. You see an overview of the frequency of the binary states and of the edge transitions.

Use the R&S®SmartGrid function to position the digital channels on the display according to your needs.
Open Lightbox

Use the R&S®SmartGrid function to position the digital channels on the display according to your needs.

Comprehensive processing and analysis functions

To efficiently analyze measured waveforms, all Rohde & Schwarz oscilloscopes offer the R&S®B1 option with a range of automatic time measurements, including statistical evaluation. Automatic measurements can be performed on all digital channels and their logical combinations. The cursor also supports the decoding of the bus value at the cursor position. The history view function allows you to access measurement waveforms in the acquisition memory and apply analysis functions to them.

Detailed analysis on the digital channels.
Open Lightbox

Detailed analysis on the digital channels.

Analysis of serial protocols

Analysis of serial protocols, even with digital channels

The protocols of serial interfaces such as I²C, SPI, UART/RS-232, CAN, LIN and FlexRay™ can also be triggered and decoded using the R&S®RTO-B1 digital channels and the appropriate serial protocol options.

Protocol decoding such as I²C decoding is also supported on digital channels.
Open Lightbox

Protocol decoding such as I²C decoding is also supported on digital channels.

Low test point loading

Low test point loading due to active probe solution

The digital inputs are grouped into logic probes with eight channels. High input impedance combined with low input capacitance of 100 kΩ || 4 pF ensures high signal fidelity and low loading of the test points.

Low test point loading due to active probe solution
Open Lightbox

Low test point loading due to active probe solution

Available models

Available models
Modèles
Number of channels
Bandwidth
Max. sampling rate
Max. memory depth
Base unit

R&S®RTO-B1

Numéro de commande 1326.3558.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
200 Msample
Base unit

R&S®RTE-B1

Numéro de commande 1326.3570.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
100 Msample
Base unit

R&S®RTA-B1

Numéro de commande 1335.7823.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
2.5 Gsample/s (16 ch)
5 Gsample/s (8 ch)
Max. memory depth
100 Msample (16 ch)
200 Msample (8 ch)
Base unit

R&S®RTM-B1

Numéro de commande 1335.8988.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
2.5 Gsample/s (16 ch)
5 Gsample/s (8 ch)
Max. memory depth
40 Msample (16 ch)
80 Msample (8 ch)
Base unit

R&S®RTB-B1

Numéro de commande 1333.1105.02

Number of channels
16
Bandwidth
300 MHz
Max. sampling rate
1.25 Gsample/s
Max. memory depth
10 Msample
Base unit

R&S®RTC-B1

Numéro de commande 1335.7281.03

Number of channels
8
Bandwidth
300 MHz
Max. sampling rate
1 Gsample/s
Max. memory depth
1 Msample
Base unit

R&S®RTH-B1

Numéro de commande 1325.9981.02

Number of channels
8
Bandwidth
250 MHz
Max. sampling rate
1.25 Gsample/s
Max. memory depth
125 ksample
Base unit

R&S®RTO6-B1

Numéro de commande 1801.6741.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
200 Mpts
Base unit

R&S®MXO4-B1

Numéro de commande 1335.4130.02

Number of channels
16
Bandwidth
400 MHz
Max. sampling rate
5 Gsample/s
Max. memory depth
400 Mpoints
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.