Promo: What's next? Taking industry leadership or watching from the sidelines?

What's next? Taking industry leadership or watching from the sidelines?

Take the lead with up to 60% off our instruments

WCDMA/HSPA+ digital standards

WCDMA/HSPA+ digital standards
Open Lightbox
WCDMA/HSPA+ digital standards, Screenshot

Key Facts

  • Uplink/downlink signal generation in line with 3GPP FDD Rel. 11
  • Including HSDPA, HSUPA and HSPA+ physical channels and features
  • Simulation of up to 4 base stations (BS) or mobile stations (MS)
  • Support of real-time operation for uplink and downlink channels
  • Test case wizard for easy test setup in line with 3GPP TS 25.141

WCDMA/HSPA+ signal generation

These digital standard options provide WCDMA/HSPA+ signal generation capabilities in line with 3GPP FDD Rel. 11. This includes all physical channels of 3GPP FDD, HSDPA, HSUPA and HSPA+.  All signals are generated either as a combination of the real-time and ARB modes or in ARB mode only (WinIQSIM2™).
Various test models and predefined settings are available to simplify signal generation as far as possible. Furthermore, a test case wizard ensures the easy setup of base station conformance tests. Various graphical displays and setting assistants also support fast and convenient signal configuration.

Caractéristiques & avantages

Support of all physical channels

All WCDMA 3GPP FDD, HSDPA, HSUPA and HSPA+ physical channels are supported. This allows the simulation of up to:

  • Four base stations (BS) with up to 128 code channels each
  • Four configurable mobile stations (MS) and up to 128 additional MS with identical configuration in parallel

Main menu, base station settings (downlink)
Open Lightbox

Main menu, base station settings (downlink)

Perfect for BER and BLER measurements

In downlink mode, the P-CCPCH and up to three DPCH can be generated in real time. In uplink mode, real-time simulation is supported for DPCCH and one DPDCH of one mobile station. This allows a 3GPP conformant continuous measurement of BER and BLER in a code channel with PN data. Furthermore, bit and block error rate insertion is supported, enabling the verification of the  base station internal BER/BLER calculations. 

DPCH bit error insertion dialog
Open Lightbox

DPCH bit error insertion dialog

Test case wizard for easy setup of BS tests

The test case wizard supports the configuration of test signals in line with 3GPP TS 25.141 for base station conformance tests. It offers a selection of predefined settings for wanted and interfering signals based on the defined test cases.

Test case wizard main dialog
Open Lightbox

Test case wizard main dialog

Quick signal configuration

The predefined settings assistant allows quick signal generation for testing amplifiers and other components.
Downlink test models in line with 3GPP TS 25.141 are provided as predefined settings:

  • Test model 1 with 4/8/16/32/64 DPCH
  • Test model 2
  • Test model 3 with 4/8/16/32 DPCH
  • Test model 4
  • Test model 5 with 8/4/2 HS-PDSCH (in case of 4 HS-PDSCH with 4 or 14 DPCH)
  • Test model 6 with 8/4 HS-PDSCH

Predefined settings dialog
Open Lightbox

Predefined settings dialog

Graphical signal evaluation

Various graphical displays support fast and easy signal configuration/evaluation:

  • Code domain display with domain conflict indication
  • Channel graph
  • Graphical signal monitoring in real time (I and Q vs. time, frequency spectrum, vector diagram, CCDF and more), including marker functions

Code domain display, 4 HS-PDSCH and 4 DPCH
Open Lightbox

Code domain display, 4 HS-PDSCH and 4 DPCH

Support of HSPA and HSPA+ physical channels

Simulation of HSUPA and HSDPA physical channels, including HSPA+ features:

  • HSDPA H-Sets 1 to 12 with channel coding and user-editable H-Set configurations
  • MIMO support including HSDPA MIMO precoding and HS-DPCCH signaling for user equipment
  • HSUPA fixed reference channels (FRC) 1 to 8 with channel coding and HARQ feedback simulation
  • Higher order modulation schemes, 64QAM in downlink and 4PAM in uplink
  • Continuous packet connectivity (CPC) 

Excerpt from channel table of HSDPA H-Set 8
Open Lightbox

Excerpt from channel table of HSDPA H-Set 8

Tailored for BS/MS tests

Several other functions are needed for 3GPP standard conformant/compliant test setups:

  • Dynamic power control support in real-time mode for up to three DPCH in downlink and one mobile station in uplink are essential for RX tests that need closed-loop power control.
  • In the uplink, the output of the FRC HARQ processes can be controlled in real time using a feedback line from the DUT to allow base station performance tests in line with 3GPP TS 25.141.

HARQ feedback simulation for 3GPP BS tests.
Open Lightbox

HARQ feedback simulation for 3GPP BS tests.

Available models

R&S®SMW200A
Modèles
Description
Base unit

R&S®SMW-K42

Numéro de commande 1413.3784.02

Description
3GPP FDD
Base unit

R&S®SMW-K83

Numéro de commande 1413.4580.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests
Base unit

R&S®SMW-K242

Numéro de commande 1413.4839.02

Description
3GPP FDD (WinIQSIM2™)
Base unit

R&S®SMW-K283

Numéro de commande 1413.6290.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests (WinIQSIM2™)
Base unit
R&S®SMM100A
Modèles
Description
Base unit

R&S®SMM-K42

Numéro de commande 1441.2008.02

Description
3GPP FDD
Base unit

R&S®SMM-K83

Numéro de commande 1441.1899.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests
Base unit

R&S®SMM-K242

Numéro de commande 1441.1701.02

Description
3GPP FDD (WinIQSIM2™)
Base unit

R&S®SMM-K283

Numéro de commande 1441.1547.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests (WinIQSIM2™)
Base unit
R&S®SMBV100B
Modèles
Description
Base unit

R&S®SMBVB-K42

Numéro de commande 1423.7747.02

Description
3GPP FDD
Base unit

R&S®SMBVB-K83

Numéro de commande 1423.7899.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests
Base unit

R&S®SMBVB-K242

Numéro de commande 1423.8189.02

Description
3GPP FDD (WinIQSIM2™)
Base unit

R&S®SMBVB-K283

Numéro de commande 1423.8337.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests (WinIQSIM2™)
Base unit
R&S®SMCV100B
Modèles
Description
Base unit

R&S®SMCVB-K242

Numéro de commande 1434.4196.02

Description
3GPP FDD (WinIQSIM2™)
Base unit

R&S®SMCVB-K283

Numéro de commande 1434.4473.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests (WinIQSIM2™)
Base unit
R&S®SGT100A
Modèles
Description
Base unit

R&S®SGT-K242

Numéro de commande 1419.6056.02

Description
3GPP FDD (WinIQSIM2™)
Base unit

R&S®SGT-K283

Numéro de commande 1419.7100.02

Description
3GPP FDD HSPA/HSPA+, enhanced BS/MS tests (WinIQSIM2™)
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Marketing de permission

Votre demande a bien été envoyée ! Nous vous contacterons dans les plus brefs délais.
An error is occurred, please try it again later.
Informations générales et conditions d'utilisation du site Web

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termes & Conditions du tirage au sort relatif aux 10 ans des oscilloscopes Rohde & Schwarz

1. Le tirage au sort “10 years Rohde & Schwarz oscilloscopes” est organisé par Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Allemagne, Tel. +49 89 41 29 0 (référencé ici par “R&S").

2. Tous les participants peuvent s'inscrire au tirage au sort du 01 janvier 2020 au 31 décembre 2020 avec leur nom, le nom de leur entreprise et leur courriel professionnel.

3. La participation est gratuite et ne dépend pas de l'achat de biens ou de services.

4. Le tirage au sort est uniquement ouvert aux entités juridiques et seules les personnes morales peuvent gagner les prix. Une personne physique n'est pas autorisée à participer en son nom propre et pour son propre compte, mais en tant que représentant d'une entité juridique en remplissant le formulaire de participation au nom et pour le compte de l'entité juridique.

5. Les prix à gagner sont 1 des 10 R&S®RTB2000 au cours de la période allant du 1 janvier 2020 au 31 décembre 2020 :

Prix : 1x oscilloscope numérique R&S®RTB2000

6. Le tirage au sort aura lieu au siège social de Rohde & Schwarz, Muehldorstrasse 15, 81671 Munich. Les gagnants des prix seront informés par courriel sous 5 jours ouvrés.

7. Le représentant autorisé de l'entité juridique devra informer Rohde & Schwarz qu'il accepte le prix. En cas de refus d'acceptation, ou sans aucune réponse dans les deux semaines, un nouveau gagnant sera tiré au sort. Si aucun gagnant ne se manifeste sous quatre semaines, le tirage au sort prend fin et le prix est perdu.

8. Les employés R&S et les membres de leurs familles, ainsi que toute personne participant au processus du tirage au sort et les membres de leurs familles sont exclus du formulaire de participation.

9. Aucun équivalent en argent ou échange de prix n'est autorisé. Les prix ne sont pas transférables. Tous les impôts, les prélèvements, les droits, les taxes et toutes autres charges perçus dans le pays du participant sont à la charge du participant.

10. Les données personnelles seront traitées uniquement dans le cadre de ce tirage au sort et supprimées quatre semaines après celui-ci, sauf indication contraire.

11. Tout participant qui ne respecte pas ces Termes & Conditions peut être disqualifié par Rohde & Schwarz de ce concours. Dans un tel cas, les prix peuvent également être retirés de manière rétroactive. Dans le cas où un prix est retiré de manière rétroactive à cause du non-respect de ces conditions, il devra être retourné par le participant en question à ses frais à l'adresse Rohde & Schwarz mentionnée au point n°1 et un nouveau gagnant sera tiré au sort.

12. Les participants ne peuvent pas réclamer les prix de ce tirage au sort et aucune procédure juridique n'est autorisée à cet égard.

13. Le tirage au sort et toute relation contractuelle qui en découle entre Rohde & Schwarz et le participant respectif sont régis et interprétés conformément aux lois de l'Allemagne, sans aucun recours au conflit de lois. Les tribunaux de Munich, Allemagne, sont seuls compétents en cas de litige émanant directement ou indirectement de la participation à ce concours.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.