The fact that cable TV networks are generally located in densely populated areas or extend over large geographical regions makes the presence of line extenders at regular intervals a necessity. Cascading large numbers of amplifiers however calls for excellent noise, SWR and intermodulation distortion specifications for the integrated amplifiers in order to avoid quality of service dropping below minimum acceptable levels. Composite second order, composite triple beat & cross modulation are commonly used figures to specify the performance of CATV equipment. In this application note we describe how to determine these figures with the aid of R&S SMU200A or AFQ100A and SMV vector signal generators.
11-Aug-2006 | AN-No. RAC-0605-016
With AMPTUNE amplifier nonlinearity can be measured with signals that are typical for the signals encountered by the amplifier in day-to-day use. The measurement can be checked by pre-distorting the control signal. Also, the results can be automatically stored for further processing with external programs.
26-Oct-2005 | AN-No. 1MA27
Voice over IP for air traffic control
19-Nov-2012
The NRT power reflection meter can measure the average burst power of TDMA signals. This application note shows how to use this feature to measure the average power in the useful part of GSM/EDGE bursts. The procedure given here can also be modified for use with other TDMA systems.
01-Dec-2003 | AN-No. 1GP47
High Speed Uplink Packet Access (HSUPA) is a 3GPP release 6 feature for WCDMA. Objective is to achieve uplink data rates of up to 5.76 Mbps and increase throughput and capacity. This application note introduces HSUPA concepts and explains key features.
09-Feb-2006 | AN-No. 1MA94
The R&S®ESW-B8 and R&S®ESW-B8E extended bandwidth options allow the R&S®ESW EMI test receiver to measure with a resolution bandwidth of up to 80 MHz. The increasing number of wideband applications (e.g. radar sensors) and accompanying standards means there is now a greater interest in wide bandwidth measurements.This application note describes the following topics for the R&S®ESW EMI test receiver:► Characteristics and implementation of RF signal paths► Image responses and how their rejection is handled ► Ultrawideband measurement applications as required e.g. by ETSI standards► Solutions for efficiently coping with bandwidth limitations in the range above 8 GHz
19-Nov-2020 | AN-No. 1EE26
Rohde & Schwarz offers a variety of products to fit your testing needs. Here, we present our solution for testing the above-mentioned use cases.
15-Oct-2018
The R&S®EDST300 efficiently and precisely analyzes TACAN and DME ground stations, making it ideal for commissioning and regular maintenance.
16-Feb-2017
Use of FSE Spectrum Analyzer for adjacent channel power measurements with wideband CDMA signals is explained. Optimum operation is shown by explanation the signal behavior and the internal structure of the FSE. The spectrum analyzer family FSE, featuring a very high dynamic range is an outstanding equipment for this purpose. Up to 73 dB dynamic range are attained.
17-Mar-1998 | AN-No. 1EF40
This application note provides information how to perform spectral emissionmeasurements on pulsed signals with spectrum analyzers using RBW filters with verywide bandwidth, and explains the capabilities and the limiting factors of the Rohde &Schwarz FSW signal and spectrum analyzer to perform this measurement.
06-Jun-2019 | AN-No. 1EF106
High sampling rate and automatic pulse analysis make the R&S®NRP-Z8x wideband power sensors ideal for time-domain analysis of radar pulses.
06-Aug-2013
broadcasting transmitters, allocated frequencies, monitoring control center, RF power, Automatic monitoring of emission parameters of registered broadcasting transmitters Automatic monitoring of emission parameters of registered broadcasting transmitters broadcasting transmitters, allocated frequencies, monitoring control center, RF power, Automatic monitoring of emission parameters of registered broadcasting
04-Sep-2006
The R&S®FSMR3000 (hereinafter FSMR) is a three-in-one instrument incorporating a Measurement Receiver, a Signal and Spectrum Analyser, and a Phase Noise Analyser.This application note demonstrates the use of the FSMR, including the Cross-correlation option (R&S®FSMR3-B60), to measure the Phase Noise characteristics of a raw Signal Generator (R&®SMA100B).The Cross-correlation phase noise measurement improves sensitivity by 5 · log(n) dB, compared with measurements that do not use this option. For example, a measurement using 10 correlations, improves the phase noise floor by 5 dB.
31-Dec-2021 | AN-No. 1SL376
The R&S®SITLine ETH provides certified cryptography to safeguard data communications within Hitachi file and content systems.
27-Jan-2014
Integrating automotive radar sensors into cars is very challenging. Radars operate behind bumpers, design emblems, in side mirrors or other plastic parts of the car. All radome materials need to be sufficiently transparent and homogeneous for automotive radars, which operate in the 77 GHz and 79 GHz band or even both simultaneously. The new system measures, visualizes and analyzes radar radomes in a manner you have never seen before. Optimize your radome material for best performance and effective integration of modern automotive radar sensors.
27-Aug-2019
IQWizard is a tool for loading IQ signal files in various formats and measuring IQ signals with a FSx spectrum analyzer or ESx Receiver. The obtained IQ data in memory can be stored in various formats or be transmitted to an R&S® vector signal generator with WinIQSIM™ or WinIQSIM2™.
26-Apr-2013 | AN-No. 1MA028
Automotive Infotainment Testing
19-Feb-2018
Next generation technologies in radar and satellite communication with high data rates call for innovative testing solutions to develop and manufacture RF components like voltage controlled oscillators (VCO). The R&S®FSPN phase noise analyzer increases efficiency and reproducibility of VCO characterization and phase noise measurements from lab to production.Voltage controlled oscillators are oscillators whose output frequency is controlled by means of an external tuning voltage, and they are used in a wide variety of electronic and RF applications like function generators, phase-locked loops including frequency synthesizers used in communication equipment. Different VCO design approaches yield different parameters and performance, and therefore it is important to measure or characterize VCOs under different conditions. This application note provides a short technical introduction to voltage controlled oscillators and explains the most common and the most important measurements made during the VCO characterization process.
17-May-2023 | AN-No. 1SL386
The UWB (Ultra-Wide Band) technology is a low power wide-band technology specified for device to device communication.It is an optimal RF positioning technology that enables accurate and secure peerto-peer distance measurement between mobile devices with robust resistance to interference while consuming very low energy and coexisting well with other radio communication systems.This application note describes how to use the UWB measurement functionality provided by R&S®CMP200 radio communication tester to perform HRP UWB PHY measurements for R&D and production purposes.
19-May-2021 | AN-No. GFM362
After a communications satellite is on its target orbit, several routines need to be performed in order to ensure proper performance from the transponders in the payload. The on-orbit measurements are a vital part of the maintenance of a live satellite as well. Operating a satellite channel for an on-orbit measurement rather than the intended application comes with significant opportunity cost and hence test duration needs to be minimized as much as possible. Rohde & Schwarz test and measurement equipment recommended in this paper is market leading not only in terms of measurement accuracy but also offers unparalleled speed of measurement. This application note focuses on satellite post-launch or on-orbit measurement and monitoring strategies used for satellite functionality checks when running maintenance routines. A complementary paper treats pre-launch payload measurements.
25-Nov-2016 | AN-No. 1MA263
This application note describes how to remotely control the R&S SGMA RF sources SGT100A and SGS100A with a special focus on their high-speed remote control capabilities via LAN based FAST Socket or FAST PCI Express (PCIe) connections which allow round trip setting times of only 100μs.It therefore provides a brief introduction into the general remote control capabilities, explains the interaction of the different SW protocol layers and drivers, and in detail describes how to establish a high-speed remote control connection. Finally, a comparison of the measured setting time performance of the different remote control approaches is provided.
12-May-2016 | AN-No. 1GP107
Rohde & Schwarz presents a customizable solution for testing barometric performance to ensure z-axis accuracy in line with FCC regulations.
24-Jun-2021
The R&S®SMW200A vector signal generator with the R&S®SMW-K78 radar echo generation option tests L-/S-/X-/Ku-band radars up to 40 GHz RF frequency more flexibly than ever before. Since it allows the object range, radial velocity and radar cross section (RCS) of radar echo signals to be configured, it is ideal for radar development, maintenance and training.
08-Sep-2016
This application note describes how to set up 3GPP FDD and LTE multicell and multi-UE scenarios with the R&S®SMU200A with a focus on routing and leveling of the baseband signals. Furthermore, it describes in detail how to determine the correct AWGN settings, i.e. how to calculate the required signal-to-noise ratio for the various scenarios.
10-Aug-2011 | AN-No. 1GP80
A Test Port Adapter System is implemented for all Rohde & Schwarz equipment, which operates above 26 GHz in order to protect the RF front-end from mechanical damage. The Test Port Adapter System consists of an RF front-end interface called the Test Port Adapter Body, and the Test Port Adapter Head which is attached to the Body. The Head provides an interface to a cable or device under test. This Application Note identifies the various types of Test Port Adapters, their parameters, compatibilities and usages.
28-Apr-2015 | AN-No. 1MA100
This application note shows how to perform LTE terminal block error rate (BLER) and throughput tests under fading conditions with the R&S®CMW500 Protocol Tester and the R&S®AMU200A Fading Simulator.
27-Mar-2012 | AN-No. 1MA177
The R&S®RTO oscilloscope is a valuable tool for analyzing EMI problems in electronic designs. High input sensitivity, high dynamic range and a powerful FFT implementation are key features for capturing and analyzing unwanted emissions.
27-Jun-2018
radiated conformance testing according to TS 38.141-2, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes all mandatory radiated RF transmitter tests (TS 38.141-2, chapter 6), according to Release 16.Furthermore, this document provides a brief introduction about the different R&S OTA antenna test solutions and how they are applicable for base station conformance testing. Rohde & Schwarz offers solutions for any test case that is mentioned in this application note.
20-Dec-2019 | AN-No. GFM324
Using R&S®ELEKTRA Migration Tool
The R&S®ELEKTRA EMC test software is the successor of the R&S®EMC32 EMC measurement software. Like the R&S®EMC32 EMC measurement software, the R&S®ELEKTRA offers a solution that controls complete EMC systems and automates measurements on equipment under test (EUT) that is being tested for emissions (EMI) and immunity (EMS) compliance. It has more features and test types compared to R&S®EMC32.As both software platforms use different file formats, R&S®EMC32 users who upgrade their existing software to the R&S®ELEKTRA platform need to perform a file conversion before migrating their data to the R&S®ELEKTRA platform. This is done by using the R&S®ELEKTRA Migration Tool, which is installed automatically with each R&S®ELEKTRA installation.This Application Note describes how to use the R&S®ELEKTRA Migration Tool (version 4.4 onwards) for converting the backup data into the XML format that can be interpreted by the R&S®ELEKTRA software. It also provides recommended conversion steps (Chapter 5) and troubleshooting tips (Chapter 6). For instructions on migrating the data using R&S®ELEKTRA Migration Tool below version 4.4, refer to the R&S®ELEKTRA user manual. For better user experience, we recommend using the latest software version for migration.This Application Note does not describe the steps to backup data using the R&S®EMC32 or R&S®ES-SCAN software. For procedures on how to do so, refer to their respective manuals.
04-May-2023 | AN-No. 1SL396