Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1104 Results
Next generation technologies in radar and satellite communication with high data rates call for innovative testing solutions to develop and manufacture RF components like voltage controlled oscillators (VCO). The R&S®FSPN phase noise analyzer increases efficiency and reproducibility of VCO characterization and phase noise measurements from lab to production.Voltage controlled oscillators are oscillators whose output frequency is controlled by means of an external tuning voltage, and they are used in a wide variety of electronic and RF applications like function generators, phase-locked loops including frequency synthesizers used in communication equipment. Different VCO design approaches yield different parameters and performance, and therefore it is important to measure or characterize VCOs under different conditions. This application note provides a short technical introduction to voltage controlled oscillators and explains the most common and the most important measurements made during the VCO characterization process.
17-May-2023 | AN-No. 1SL386
- not available -
01-Aug-1997 | AN-No. 7BM39
Reliable testing of HARQ feedback and UL timing adjustment on LTE eNBs with the R&S®SMW200A simplifies eNB performance testing and eliminates the need for test UEs
01-Jun-2016
Frequency converters e.g. in satellite transponders need to be characterized not only in terms of amplitude transmission but also in terms of phase transmission or group delay, especially with the transition to digital modulation schemes. They often do not provide access to the internal local oscillators. This application note describes a method using the R&S®ZNA analyzer family to measure group delay of mixers and frequency converters with an embedded local oscillator very accurately. The key aspect of this new technique is that the network analyzer applies a 2-tone signal to the frequency converter. By measuring the phase differences between the two signals at the input and at the output, it calculates group delay and relative phase.
11-Jul-2019 | AN-No. 1EZ81
With the R&S®RTB2000/RTM3000/RTA4000 oscilloscopes, you control and interact remotely via LAN. These oscilloscopes incorporate the USB-based connectivity standard media transfer protocol (MTP).
20-Mar-2017
Especially with test receivers not comprising a built-in disk drive (ESHS10, ESVS10, ESVD, ESVB and ESPC) it is necessary to store instrument settings before a firmware update or before changing the battery of the static memory to be able to restore the settings later on. Frequently it is desirable to exchange settings or comprehensive data like transducer sets between receivers, or receivers have to be set up to suit different applications.
18-Jan-2002 | AN-No. 1EE20
For automated test applications, measurement time is often as important as the quality of the measurement. As with many situations, time is money. In practice, phase noise measurements are generally not considered fast, but test engineers still desire to save as much test time as possible. The Rohde & Schwarz®FSWP (FSWP) is a modern, digital signal processing based, phase-noise test set that performs many tasks in parallel in an effort to improve measurements speed. However, several measurement settings drastically affect measurement speed. This paper will discuss these settings and provide suggestions on improving overall measurement speed.The three key instrument parameters that affect FSWP measurement speed are:1. Number of cross correlations2. Resolution bandwidth (RBW)3. Offset frequency span
08-Oct-2020 | AN-No. GFM354
Calibration and Verification Solution
The UWB (Ultra-Wideband) technology is a short range wide-band radio technology specified for device to device communication operating in unlicensed spectrum. It is an RF positioning technology that enables accurate and secure peer-to-peer ranging between mobile devices with robust resistance to interference while consuming very low energy and coexisting well with other radio communication systems. UWB is used for a variety of different applications, such as asset tracking, secure payment, personal tracker, real time location services and keyless access and start of a vehicle etc. According to ABI Research forecasts, there will be well over 1 billion UWB annual device shipments by 2026. Almost every smart phone shipped in 2026 will support UWB services.Talking about testing aspect of a UWB device, in general two test methodologies can be adopted as other wireless products, either the traditional testing mode (so-called conducted test mode) with wired RF connection between the test measurement equipment and device under test (DUT) or over the air (OTA) test mode in an OTA anechoic chamber. Sometimes, it is not always possible or necessary to perform the tests under conducted mode due to the limiting factors, e.g. cost, space, complexity and direct access to the RF connectors of the product. In this case, OTA testing is then becoming a non-evitable approach. Moreover, OTA testing reflects the usage of DUT in a real condition.In this application note, R&S® OTA test solution covering transmitter (Tx), receiver (Rx) and Time of Flight (ToF) testing in Wireless Automated Testing (WMT) environment is described. The measurement results throughout the whole document are based on NXP Trimension™ NCJ29D5 UWB automotive IC.
12-Apr-2023 | AN-No. 1SL394
conducted conformance testing according to TS 38.141-1, Rel. 16
3GPP defines the Radio Frequency (RF) conformance test methods and requirements for 5G NR Base Stations (BS) in the technical specifications TS 38.141. This application note describes how all mandatory RF transmitter tests (TS 38.141-1, chapter 6), according to Release 16, can be performed quickly and conveniently with signal or spectrum analyzers from Rohde & Schwarz by either choosing manual operation or a remote control approach. Moreover, some test cases require additional signal generation equipment from Rohde & Schwarz.In Addition, a new Python software library comes with this application note to enable the remote control approach of base station testing. This example requires the RsInstrument module which can be found on pypi.org or installed via 'pip' and is provided as is.
27-Jan-2021 | AN-No. GFM313
7BM37 MPEG2,DVRG,Broadcasting,DTV Transfer of Video Stream Files to and from DTV Recorder Generator DVRG Transfer of Video Stream Files to and from DTV Recorder Generator DVRG 7BM37 MPEG2,DVRG,Broadcasting,DTV Transfer of Video Stream Files to and from DTV Recorder Generator DVRG Related products
31-Jul-2003 | AN-No. 7BM37
The R&S®Pulse Sequencer software offers a powerful mechanism to model sequences that are often required for meaningful radar receiver test cases. The sequences can consist of many individual elements, such as pulses defined by the software or imported waveform segments. The software’s powerful interpulse modulation mechanism gives the user full control of each single element.
03-Oct-2017
This application note is to provide a basic understanding as to the configuration and control of DVQ via an Ethernet link.
26-Apr-2001 | AN-No. 7BM04
The R&S®RTB2000 digital oscilloscope lets you share your scope’s display with any computer/projector via LAN or Internet. The oscilloscope comes with an RJ-45 Ethernet jack and a built-in web server (as standard). The screen is displayed via a direct connection to a PC, via LAN or over the Internet.
21-Mar-2017
In this whitepaper we describe the device to device communication in LTE from a UE point of view. Network elements are described as far as they concern the UE. In addition to the message transmission and reception, a special emphasis is put on the synchronization between UEs and on the security for the message exchange.
29-Sep-2015 | AN-No. 1MA264
3GPP TS36.141 defines conformance tests for EUTRA base stations (eNodeB). Release 14 added several tests, especially for enhanced License Assisted Accsess (eLAA).This application note describes how all required transmitter (Tx) tests (TS36.141 Chapter 6) can be performed quickly and easily by using signal and spectrum analyzers from Rohde & Schwarz. A few tests additionally require signal generators from Rohde & Schwarz.Examples illustrate the manual operation. A free software program enables and demonstrates remote operation.The LTE base station receiver (Rx) tests (TS36.141 Chapter 7) are described in Application Note 1MA195.The LTE base station performance (Px) tests (TS36.141 Chapter 8) are described in Application Note 1MA162.
11-May-2016 | AN-No. 1MA154
Increasing data rates in high-speed digital designs and wireless communications require SerDes PLLs and clock synthesizers with low additive phase noise and high jitter attenuation. Modern designs often follow a two-stage architecture, consisting of a jitter-attenuator and a frequency-synthesizer stage. Due to their high phase noise sensitivity, phase noise analyzers are the instruments of choice for these tests. To stimulate the PLL, an additional signal source with ultra low phase noise is required.
01-Aug-2018
Functional Testing
Although data services in the context of eMBB, URLLC and mMTC are the pivotal drivers behind the 5G evolution, legacy services like voice and video communications still represent important services that operators want to offer to their subscribers. As part of the technology evolution, we have seen a major change from circuit-switched 2G networks with an initial focus on telephony to fully packet-switched 4G networks focused on internet data communications.This application note focuses on different details of voice services in 5G networks. Besides some theoretical background this document describes the procedure to setup a 5G network with R&S®CMW500 and R&S®CMX500 radio communication testers and how to carry out different functional voice call tests for 5G networks.
06-Oct-2021 | AN-No. 1SL364
The R&S®CMW500 and R&S®SMBV100B are the ideal team for motor vehicle type approval testing of your eCall and ERA-GLONASS cellular modems and their GNSS receivers in line with the EU2017/79 regulation.
02-May-2022
In this day and age of internet of things, more and more devices are connected to the local network, making it even more difficult for the IT department to monitor them. Rohde & Schwarz instruments are also increasingly accessed via their LAN interface, which provides additional convenience features such as remote desktop, SMB file transfer or a web interface. To make it easier to monitor the use and status of instruments, some devices offer a software option, the Health and Utilization Monitoring Service (HUMS).HUMS can be accessed via SNMP and REST (HTTP) and provides all necessary information about the health status and utilization over time in many details.This application note describes how to access HUMS and what data is provided.
11-Jan-2021 | AN-No. GFM336
30 dBm + 30 dBm = 60 dBm? It is well known that it is not as easy as that.
This application note supplies a free of charge software tool that can be used to add or subtract an arbitrary number of powers. In addition, the software can be used to convert power and voltage units from the linear to the logarithmic scale (and vice versa), convert linear power and voltage ratios to decibels, and convert a VSWR to other reflection quantities.
10-Dec-2018 | AN-No. 1GP77
Bluetooth Low Energy (BLE) 5.1 has introduced Angle of Arrival (AoA) and Angle of Departure (AoD) to enrich the direction finding (DF) feature. This application note gives the guidance of how to perform the BLE 5.1 DF RF tests according to the RF test specification of BT 5.1 by using the Rohde & Schwarz test solutions.
30-Oct-2019 | AN-No. GFM327
More and more mobile radio networks implement remote radio equipment (RE) that is connected to the base station main unit via a digital interface using standardized transmission protocols such as CPRI. For testing RE devices Rohde & Schwarz offers a complete test solution based on the R&S®EX-IQ-BOX [Model K04]. This key component is a configurable digital interface module that is used to connect Rohde & Schwarz test equipment to a RE under test using CPRI data transmission. This application note explains in detail the instrument setup and configuration needed to successfully test your remote radio head.
05-Aug-2013 | AN-No. 1GP78
The R&S®QPS quick personnel security scanner transforms people-screening technology with its high-performance, fully electronic and solidstate flat panel design that has no moving parts. The R&S®QPS improves the security screening experience and operations by having a simple open design for a spacious screening environment and unobstructed view for security personnel, making high-resolution people screening more comfortable and efficient than ever before.
15-Apr-2019
Monitoring on up to 10 000 channels with different parameter settings
13-Jul-2012
The strict requirement of network synchronization is as old as digital cellular mobile networks. As soon as cells have a neighbor relationship, network synchronization is mandatory in both the frequency and time domains in order to ensure UE QoE and performance (Handover, MIMO, data throughput, etc.). This educational note describes how 5G NR with its extremely flexible specifications is affected by these synchronization requirements, and how it can be measured?
17-Aug-2021 | AN-No. 8NT05
This application note describes Methods of Implementations (MOI) for precise, fast and error-free compliance testing of high-speed backplanes and direct attach copper cables (DAC) according to InfiniBand EDR and HDR specifications, based on 25 Gb/s and 50 Gb/s signaling per lane with vector network analyzers from Rohde & Schwarz.
07-Apr-2021 | AN-No. GFM357
From designing a test setup to performing accurate measurements
Double-Pulse testing is a standard test-method used in power electronics design. Accurate measurements require a careful design of the test setup and the selection of the right measurement instruments. This application note discusses important aspects of double-pulse test setups as well as how to perform accurate measurements.
22-Mar-2021 | AN-No. GFM347
A high frequency transformer is a key component when designing isolated switching mode power supplies (SMPS). Leakage inductance is essential in the control of many design parameters including efficiency, maximum voltage rating for switching elements and EMI when it comes to designs using customized transformers. Accurate measurement of this parasitic element is mandatory. The R&S®LCX LCR meter is ideal for this challenging measurement task.
15-Feb-2022
Due to today’s worldwide highly competitive communications market, achieving shorter product design cycles, quicker response to customer requests and high-volume product runs at low costs is vital for manufacturers of wireless devices and components. These requirements inevitably lead to demands for improving the throughput of Automated Test Equipment (ATE) by increasing its speed. This application note describes in detail how the special features of the R&S® SMATE200A can be used to optimize speed and throughput in an automated test environment.
17-Apr-2007 | AN-No. 1GP63