Frontends and general concept |
Echo generation type | | Dynamic artificial object generation |
Echo generation concept | | Hybrid - analog for short object distances <17 m and larger distances digital |
Remote Frontends | R&S®AREG8-24S/-24D/-81S/-81D | Classical mmW remote frontends |
| R&S®QAT100 | Innovative R&S®QAT100 el. controllable antenna array |
Max. number of remote frontends per base unit | with R&S®AREG8-24S/-24D/-81S/-81D | Up to 4 classical mmW remote frontends |
| with R&S®QAT100 | Up to 8 with R&S®QAT100 |
Frequency |
RF frequency bands | with R&S®AREG8-24S/-24D | 24-24.25 GHz |
| with R&S®AREG8-81S/-81D | 76-81 GHz |
| with R&S®QAT100 | 76-81 GHz |
Instantaneous bandwidth | with R&S®AREG8-B9 | 1 GHz |
| with R&S®AREG8-B9 and R&S®AREG8-K527 | 2 GHz |
| with R&S®AREG8-B9, R;&S®AREG8-K527 and R&S®AREG8-K528 | 4 GHz |
Artificial objects |
Minimum artificial object distance | with R&S®AREG8-B9 | < 17 m + air gap |
| with R&S®AREG-B9 and R&S®AREG-B63 | < 4 m + air gap |
Covered distance range of artificial objects | with R&S®AREG8-B9 | < 17 m to 3000 m |
| with R&S®AREG8-B9 and R&S®AREG8-B63 | < 4 m to 3000 m |
Max number of artificial objects per R&S®AREG800A base unit | with R&S®QAT100 | Artificial object distance < 4 m to 17 m:
Up to 4 with individual azimuth, distance, RCS, Doppler
Artificial object distance > 17 m:
Up to 8 with individual azimuth, distance, RCS, Doppler |
| with R&S®AREG8-24S/-24D/-81S/-81D | Artificial object distance < 4 m to 17 m:
Up to 4 with individual distance, RCS, Doppler (1 per mmW frontend)
Artificial object distance > 17 m:
Up to 32 with individual distance, RCS, Doppler (8 per mmW frontend) |
Object distance step size | | < 2,5 cm (nom.) |
| Object distance accuracy | < 5 cm (meas.) |
Air gap to device under test | | Recommendation: air gap should be large enough to match far field condition of radar under test |
Radial velocity |
Individual radial velocity for each object | | Yes |
Doppler setting range | | ±500 km/h |
Velocity step size | | 0.001 km/h (meas.) |
Level |
Dynamic RCS range for all artificial objects together | with R&S®AREG8-24S/-24D/-81S/-81D | 90 dB |
| with R&S®QAT100 | 80 dB |
Dynamic RCS range for multiple objects per IF path | with R&S®AREG8-24S/-24D/-81S/-81D | 60 dB |
| with R&S®QAT100 | - |
RCS control step size | | 0.5 dB |
Amplitude flatness | R&S®QAT100 standalone | < ± 5 dB in 4 GHz bandwidth (meas.) |
Maximum RX power at frontend | with R&S®QAT100 | 0 dBm @ 77 GHz (nom.) |
Recommended RX power at frontend | with R&S®QAT100 | -20 dBm @ 77 GHz (nom.) |
Minimum RX power at frontend | with R&S®QAT100 | -60 dBm @ 77 GHz (nom.) |
Maximum Tx power at frontend | with R&S®QAT100 | 0 dBm @ 77 GHz (nom.) |
IF input/IF output interface |
IF output port | with R&S®AREG8-K740 | IF outputs on base unit for EIRP and radar signal parameter measurements |
IF input port | with R&S®AREG8-K741 | IF input on base unit for superimposing interferers |
Hardware-in-the-loop interface |
Dedicated HiL interface | with R&S®AREG8-K109 | HiL co-processor |
HiL interface update rate | with R&S®AREG8-K109 | < 0.2 ms (meas.) |
Open-standard protocol support | with R&S®AREG8-K109 | Open simulation interface (OSI) |
User interface and remote controls |
Graphical user interface with touch controls | | Yes |
Remote control interfaces | | Ethernet |
| with R&S®AREG8-K986 | GPIB |
Remote control command set | | SCPI |
General parameters |
Size | | 5 HE, 19” width |
Weight | depending on options | 15 – 26 kg |