86 Results
R&S ZNA Vector Network Analyzer - Product Brochure
Firmware for ZNA67_2 Title Versions Last Modified File Size R&S®ZNA Firmware Download up-to-date firmware for your Rohde & Schwarz product. V 2.74 02.03.2023 2 MB
The R&S®ZNA high-end vector network analyzers offer a DUT-centric approach, an excellent RF-performance, a unique hardware concept and touch-only operation.
Does the option ZNA-K1 (Spectrum analyzer mode) also work with the Millimeterwave Converters?
In combination with the time domain option R&S®ZNA-K2 and the extended time domain option R&S®ZNA-K20, the R&S®ZNA VNA offers a variety of signal integrity measurements.
Ready for Spectrum Analysis The Rohde & Schwarz Vector Network Analyzer R&S®ZNA features a spectrum analyzer option (R&S®ZNA-K1). The Rohde & Schwarz Vector Network Analyzer R&S®ZNA features a spectrum analyzer option (R&S®ZNA-K1). The spectrum analyzer mode can be used at each of the four ports of the R&S®ZNA.
15-Jan-2019
New R&S ZNA high-end vector network analyzer combines outstanding RF performance with a unique operating conceptRohde & Schwarz introduces the R&S ZNA, a new generation of high-end vector network analyzers offering outstanding RF performance and a unique hardware concept that simplifies measurement configuration.
This document provides the technical specifications of the R&S®ZNA67EXT vector network analyzer system.
13-Oct-2020
Rohde & Schwarz announces awards success with touch-operated analyzerThe R&S ZNA vector network analyzer is named the Test, Measurement & Inspection product of the year at the Electronics Industry Awards.
07-Apr-2021
Rohde & Schwarz introduces new R&S ZNA vector network analyzers with up to 67 GHz frequency rangeThe R&S ZNA high-end vector network analyzer (VNA) now features models with 50 GHz and 67 GHz maximum frequencies. This opens up the VNA’s outstanding RF performance, unique hardware concept and innovative touch operation to new areas of application. Signal integrity measurements as well as A&D and 5G component and module characterization are main applications for the new analyzer models.
Vector Network Analyzers of t ZNA and ZNB family are able to measure magnitude and phase of complex S-parameters of a device under test (DUT) in the frequency domain.
30-Jul-2020 | AN-No. 1EP83
Calibration, METAS, ZNA, ZNB, ZN-Z270, ZN-Z235, ZN-Z229, ZN-Z224, Uncertainty, Traceability, Traceable S-Parameters This video shows the practical steps that an engineer must perform to calibrate the R&S®ZNA, run a verification test and more.
With the introduction of the R&S®ZNA K50 measurement uncertainty option, Rohde & Schwarz has partnered with METAS to bring the power of VNA Tools to the R&S®ZNA. This video is a short summary of how the METAS research can benefit the engineer who makes traceable S-parameter measurements.
The user is requested to move results from a Network Analyzer to the controller PC or to a network drive.
13-Jan-2022
Rohde & Schwarz and FormFactor support the University of Texas at Austin in research on improved RF switches for 5G and 6GThe University of Texas at Austin, Rohde & Schwarz and FormFactor have collaborated to characterize a new technology for RF switches that improves battery life performance and supports higher bandwidths and switching speeds.
The R&S®ZNA high-end vector network analyzers offer a DUT-centric approach, an excellent RF-performance, a unique hardware concept and touch-only operation.
Rohde & Schwarz User Manual for the R&S®ZNA Vector Network Analyzer
A computer simulation for the R&S®ZNA, R&S®ZNB, R&S®ZNBT and R&S®ZND that can be used to test a remote control program without the need for any VNA hardware.
06-May-2019
Rohde & Schwarz presents wide variety of T&M solutions at first EuMCE event in PragueRohde & Schwarz will take part in the newly created European Microwave Conference in Central Europe (EuMCE) in Prague. The T&M specialist will present products and solutions for applications ranging from wideband radar, shielded mmWave device testing and multiport device testing to thermal effects diagnostics.
ZNA/ZVA - Mounting of the converters ZCxxx
ZNA/ZNB: Export all mixed mode S-Parameters
ZNA, ZNB, ZND - Power off after stop of the Sweep?
The attached pdf document explains how to install the tool and how to configure the remote connection to the HMP power supply.
I got a calibration kit with a sliding match standard. But there are no correction values for the NWA supplied.
How can I export the traces of a specific channel into one file, i.e. CSV?
I perform a calibration with remote commands. With the command to start the calibration sweep with a short standard I get this error message. What is the problem?
When I export the time domain trace the stimulus values are in Hz, but not in seconds as shown on the screen. How can I get the export in time or distance?
I want to use my ZNA as true differential signal generator for a constant CW signal.
Calibration of two channels simultaneously with remote commands