35 Results
Models: R&S®ESR3, R&S®ESR7, R&S®ESR26
The paper compares the measurement speed and level measurement accuracy of a conventional stepped frequency scan versus an advanced FFT-based time domain scan.
29-Jan-2014 | AN-No. 1EE24
Models: R&S®ESR3, R&S®ESR7, R&S®ESR26
Models: R&S®ESR3, R&S®ESR7, R&S®ESR26
R&S®ESRは、EMIテストレシーバーです。周波数レンジは、10 Hz ~ 26.5 GHzでCISPR16-1-1 規格に準拠しています。従来のステップ周波数スキャンまたはFFTベースの超高速タイムドメインスキャンによって電磁波妨害を測定できます。
The R&S®ESR is an EMI test receiver for the frequency range from 10 Hz to 26.5 GHz and complies with the CISPR 16-1-1 standard. The receiver measures electromagnetic disturbances with the conventional stepped frequency scan or – at an extremely high speed – with an FFT based time domain scan.
R&S®ESR EMI测试接收机的频率范围为10 Hz至26.5 GHz,符合CISPR 16-1-1标准。接收机可通过常规步进频率扫描或高速FFT时域扫描来测量电磁干扰。
This application note provides a description of the Rohde & Schwarz Click Rate Analyzer software.
15-Jan-2015 | AN-No. 1EE25
The LCR meters R&S®LCX100 and R&S®LCX200 precisely measure the complex impedance and the resulting components values over a wide frequency range.
14-Mar-2022 | AN-No. 1GP132
Assisting Tools for Operation of Windows-Based T&M Instruments
13-Jun-2013 | AN-No. 1MA218
Security, Manual, ESR, EMI Text Receiver
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Apple iPad as if working on it locally.
28-Mar-2013 | AN-No. 1MA216
Rohde & Schwarz user manual for the R&S®ESR Test Receiver; it provides all the information specific to the instrument. Other operating modes and applications are described in the specific application manuals.
I already have ESR/ESW Receivers and I would like to know, if this existing device can be calibrated as required by CISPR 16-1-1:2019 (Ed.5)?
R&S®ESR Quick Start Guide
Application video: Low-ESL/ESR measurements of DC-Link capacitors This video shows how you can precisely characterize the ESR and ESL of electric vehicle traction inverter DC-link capacitors over a frequency range of interest using the Zurich Instruments MFIA impedance analyzer.
Scan Table, exclamation mark appears near to the Bandwidth setting.
FAQ - Remote command „CALC:UNIT:POW DBUV” is not accepted
Self Alignment via remote control via TCP/IP => 'CAL?
I have a file on my device. How can I get it in a simple way to my PC?
This application note shows how to configure, calibrate and perform conducted EMS measurements according to IEC / EN 61000-4-6 and EMI measurements according to CISPR 16-2-1 with the R&S®EMC32 software tool.
19-Jul-2013 | AN-No. 1MA212
This document describes how a Windows®-based R&S® T&M instrument is remotely operated by an Android™ tablet as if working on it locally.
22-Aug-2013 | AN-No. 1MA236
This paper describes the characterization of aluminum electrolytic capacitors specifically used in AC-DC power converter applications. It will be discussed why this capacitor technology is critical regarding lifetime and why it cannot be substituted simply by any another capacitor technology. Different aging effects of the capacitor will be discussed. Usage of the capacitor in different AC-DC converter topologies will be presented. Simulation circuits will be used to analyze the capacitor in more detail before suitable measurements will be performed to demonstrate a real example of a switching-mode power supply (SMPS).After the introduction into the aluminum electrolytic capacitor basics and theory, this paper will also present all important and possible measurements of capacitor parameters, like capacitance, equivalent series resistance (ESR) and ripple current. This includes in-circuit measurement which can be performed with an oscilloscope. An LCR-bridge is used to obtain high accuracy measurements in addition. A comparison between the two measurement methods will be presented. Furthermore, the required measurement hardware for the in-circuit measurements and the bridge measurement will be discussed and presented.Lastly, two different lifetime calculation methods are presented and a real example is used to compare the advantages and disadvantages of the different methods.Thanks to Mr. Frank Puhane from Würth eiSos GmbH & Co. KG who provided me with all aluminum electrolytic capacitor samples including the prepared capacitor with build-in temperature sensors to perform all measurements. Furthermore, his great expertise was very beneficial and helpful to create this premium application note.
07-Feb-2023 | AN-No. 1SL388
EMC system solutions from Rohde & Schwarz - Customized EMC test systems - Brochure
This application note shows all necessary settings for performing Dual Receiver Measurement using the R&S®EMC32-K27 option via R&S® EMC32 Measurement Software.
28-Sep-2017 | AN-No. 1SP20
15-Mar-2022
New R&S LCX strengthens Rohde & Schwarz portfolio for high performance impedance measurementsWith a completely new family of high performance LCR meters, the frequency range of impedance measurements provided by Rohde & Schwarz test equipment is dramatically extended to cover AC components operating from 4 Hz to 10 MHz, supporting all practical applications. The R&S LCX family of LCR meters serves all established impedance measurements plus specialized measurements for selected component types and provides both, the high accuracy required in R&D, and the high speed needed in production test and quality assurance.
The history of measuring receivers at Rohde & Schwarz Reprint NEWS 224