Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
Search Application Notes & Cards
Learn how to configure Rohde & Schwarz products to fit your application. Search our database by product, technology, or application to find relevant technical documents.
1104 Results
This application note examines both the theory and practice of state-of-the-art spectrum analysis by discussing specific measurements taken on an integrated RF amplifier.The theoretical portion of this document first describes how modern spectrum analyzers are designed and how they work. That is followed by a brief characterization of today's signal generators, which are needed as a stimulus when performing amplifier measurements. The effects on the spectrum that are caused by the nonlinearity of real devices under test are derived mathematically.The practical portion of this application note contains detailed test and measurement tasks that are suitable for use as lab exercises performed in small groups. The purpose of these tasks is to illustrate the explanations provided in the theoretical section and to provide a deeper understanding of the principles explained there.
05-Mar-2013 | AN-No. 1MA201
The converters offered for the R&S®ZVA family extend the network analyzers' frequency range up to 325 GHz. This Application Note describes typical measurements on millimeter-wave mixers and millimeter-wave frontends. It also discusses a signal identification method that enables spurious measurements to be performed in the millimeter-wave range using an R&S®ZVA network analyzer in conjunction with a converter.
17-Nov-2008 | AN-No. 1EZ57
The option ZVR-B7 allows an enhanced power calibration of the source and of the receiver channels of a ZVR, then being active instead of the standard factory power calibration. Using an external power meter, the power level of input or output wave quantities will be adjusted to a desired value at an arbitrary reference plane.
29-Jul-1998 | AN-No. 1EZ41
Automatic generation and use of transducer factors makes it possible to test out-of-band emissions with the R&S®ETH handheld TV analyzer, without an external bandstop filter.
11-Aug-2010
Since the video signal - composite or component - is a most complex one regarding the spectral density or even the group delay in the baseband, you need special procedures to measure the signal parameters with an objective and absolute accuracy of less than one percent over the whole frequency range up to 6 MHz. The following describes a method allowing the precise measurement of a baseband signal, which then may be taken for the calibration of video analyzers such as the well-known R&S units UAF or UVF and future products.
20-Jul-2001 | AN-No. 7BM22
Vector Network Analyzers (VNA) are gaining popularity in the Signal Integrity community as time domain measurement and analysis tools. VNAs with 8 ports or more can provide significant decreases in test time by migrating from a 4-port measurement system to an 8-port measurement system. For tight tolerance DUTs that are barely within the test limit lines, small increases in accuracy can be realized by testing all of the test parameters at once, because the entire test setup is at the same temperature. This application note discusses the thermal advantages of testing an 8-port DUT with the R&S ZNBT VNA. The use of the ZNBT to assess and debug two differential pairs in a 20-inch backplane is presented.
18-Mar-2020 | AN-No. 1EZ83_0E
Starting from June 2017, almost all radio transmitters and receivers sold or put into operation in the European Union have to be tested for immunity against interferers in adjacent frequency bands. ETSI standard EN 303 340 defines the tests to be performed on digital television receivers and requirements to be passed.This application note describes the test procedures and provides save-recall files and interferer signals for the Broadcast Test Center R&S®BTC.
11-Jul-2017 | AN-No. 1GP116
This application note shows how to configure the R&S®AdVISE visual inspection software to automate the immunity testing in line with EN 55020 and CISPR 35 on TV sets and monitors.
30-Jul-2020 | AN-No. 1S007
Testing the RF parameters of a WCDMA base station during the network rollout phase ensures subsequent trouble-free operation of networks as a basic prerequisite for general UMTS customer acceptance. This document describes a complete solution for testing the main transmission and reception parameters according to Specification 3GPP TS 25.141 FDD R99 on the basis of the R&S CMU300 Radio Communication Tester (RF measurements) and the NetHawk RNC/Iub Simulator (base station controller). The solution presented here is particularly recommended for installation measurements and regression tests on new UMTS system components.
15-Oct-2004 | AN-No. 1CM56
PESQ measurements employ a level adaptation algorithm and are hence widely insensitive to absolute level. However, if the tests are performed via a speech codec, the driving level of the codec has an influence on the MOS result. Therefore careful alignment of the level is required. This application note provides an application program which runs on the Audio Analyzer R&S UPV or R&S UPV66 and can be used to calibrate signal levels for the PESQ measurement.
30-Jun-2011 | AN-No. 1GA50
During wireless transmission over the air a signal is subject to fading. Since fading can strongly influence the communication, devices such as mobile phones must be tested under real-world conditions to verify their performance. The Rohde & Schwarz vector signal generators R&S®SMW200A, R&S®SMU200A and R&S®AMU200A make it possible to perform such tests. Their integrated real-time fading simulators reproduce well-defined and repeatable real-world test scenarios to bring reality into your laboratory. A multitude of standard-compliant, preconfigured fading scenarios make the configuration as easy as possible.This application note gives a brief introduction to fading and explains how to use the fading simulators in custom applications.
26-Apr-2013 | AN-No. 1GP99
The 3GPP TS 36.521-1 “Radio transmission and reception” LTE User Equipment (UE) conformance specification defines the measurement procedures for LTE terminals with regard to their transmitting characteristics, receiving characteristics and performance requirements as part of the 3G Long Term Evolution (3G LTE) standard.This application note describes how to use the LTE Frequency Division Duplex (FDD) and Time Division Duplex (TDD) measurement functionality associated with the Downlink Carrier Aggregation feature of the R&S®CMW500 wideband radio communication tester to perform LTE R10 receiver measurements according to this test specification.
09-Apr-2015 | AN-No. 1CM103
Make more accurate power rail measurements.
09-Jul-2020
The RSIB interface enables the network analyzers of the ZVR family to be controlled by means of Windows applications via DDE. The interface functions are contained in the DLL RSIB.DLL. The other DLL RSDDE.DLL provides functions for the DDE access to the instrument firmware. These functions are used by RSIB.DLL. The interface of these functions greatly corresponds to that of National Instruments for programming the GPIB. The function names are similar to those of the NI library but preceded by RSDLL. The two DLLs are part of the firmware and are updated with the firmware update kits.
31-Jul-1998 | AN-No. 1EZ33
The R&S®QPS quick personnel security scanners are new, high-resolution security scanners designed specifically to make people screening at security checkpoints faster, more effective and comfortable.
23-Jan-2019
The R&S®SMBV100B signal generator offers a remote emulation feature that makes it possible to control the instrument by commands other than the built-in native SCPI commands. This feature allows the user to replace signal generators, e.g. from other manufacturers, with the R&S®SMBV100B without having to change the remote control code.This application note describes how to use the remote emulation feature in general. Furthermore, it describes in detail the remote emulation for each supported instrument, limitations of the individual emulations and the remaining differences between the emulated and the original commands.
30-Sep-2019 | AN-No. 1GP121
To analyse the quality of CD players, lots of measurements have to be done. This application note presents a program, which combines these measurements to an automatically running sequence and gives a printout of the results. A test CD is used for generating the test signals. Here the Audio Test Disc UPA-CD from Rohde & Schwarz is used, which holds all required signals in a sequence permitting automatic measurements to be carried out, without the need of controlling the CD player. In addition, this application note explains the measurements and informs about the different standards.
16-Feb-1998 | AN-No. 1GA21
A vector-modulated microwave signal can be generated by mixing an I/Q-modulated signal with a microwave carrier. This Application Note describes the frequency upconversion using a standard passive mixer. The basics of mixer operation are introduced and the conversion process is demonstrated in detail with a test setup and corresponding measurements. The mixer selection guide will make it easier to choose a proper mixer for individual applications.
18-Dec-2008 | AN-No. 1GP65
The Society of Cable Telecommunications Engineers (SCTE) defined the ANSI/SCTE 40 specification: Digital Cable Network Interface Standard. ANSI/SCTE 40 tests are designed to test conformance of set-top boxes and other cable receiving equipment to ensure that they will operate correctly when installed in a cable system. The tests are a combination of noise (AWGN and phase noise), AM hum, micro-reflections, digital and analog adjacent channels, and other discrete interferences. These impairments are found on most cable systems to some degree. Rohde & Schwarz provides set-top box manufacturers with an easy solution to perform conformance testing in line with ANSI/SCTE 40 by using the R&S®SFU broadcast test system and the R&S®SFE100 broadcast tester. The R&S®SFU is able to perform most of the test procedures in one unit. Furthermore, additional test transmitters allow the simulation of full channel loading. This Application Note explains the specific test requirements, a possible setup, and the configuration using the R&S®SFU/SFE100.
29-Oct-2009 | AN-No. 7BM68
Determining the noise figure of a component can be difficult in unshielded lab environments. Measuring small noise figures (less than 3 dB) and reproducing the results is sometimes not possible. These difficulties are caused by interference effects (electric fields) that can occur in any environment. A suitable remedy is a measurement environment able to shield the Device Under Test (DUT) against all interfering fields in the range up to 3 GHz. When used in conjunction with a spectrum analyzer and Noise Measurement Software FS-K3, the Shielded Box ZA-SB10 provides a complete noise measurement system.
16-Oct-2002 | AN-No. RSH01
RF system noise contributions define receiver capabilities and sensitivity. The noise figure measures how the critical components affect the signal.
28-Jan-2022
The new R&S®DATA-NPT mobile network performance test from Rohde & Schwarz brings innovation to network performance testing. The patent-pending testing solution is a very compact and resource-saving implementation of a new measurement procedure that simultaneously measures the maximum data capacity and the minimum continuous connectivity in a mobile network.
21-Apr-2016
Leaving aside the microwave generators, the present line of Rohde & Schwarz products comprisessignal generators up to 1 GHz (SMX, SMG), up to 2 GHz (SMH, SMGU), up to 3 GHz (SME, SMT) and up to 4.3 GHz (SMHU). For applications at higher frequencies, all signal generators can also be operated with an external passive frequency doubler. This extends the range of possible applications up to 8.6 GHz. Some degraded specs regarding level and modulation are described below. For people using the frequency range 3 to 6 GHz, the low priced combination SMT plus frequency doubler will mainly be interesting. Signal generator SMHU is useful for the frequency range up to 8.6 GHz. Especially the phase noise performance is excellent with this instrument. the required output signal. It should also be pointed out that the residual FM and the SSB phase noise will be 6 dB poorer as a result of frequency doubling.
20-Apr-1998 | AN-No. 1GPAN03
This document describes WLAN tests which rely on communication (signaling) between R&S®CMW and device under test (DUT) and on transmission of packet data over WLAN. On the R&S®CMW side the WLAN Signaling application is required, for some tests also the Data Application Unit (DAU).The test principles and the necessary settings are explained and background infor-mation is given. Step-by-step procedures are provided for the main configuration tasks.
08-Feb-2016 | AN-No. 1C107
Multichannel signal reception in parallel using digital downconverters in a monitoring receiver.
14-May-2014
The use of Rohde & Schwarz device drivers under VEE software is not complicated. However, a number of factors are involved, the errors that occur are often difficult to diagnose. This application provides easy and detailed support for installation and troubleshooting using National Instruments or Agilent GPIB boards.
20-Dec-2012 | AN-No. 1MA035
This Application Note introduces the new interferer management option, R&S SFU-K37 and describes how this can be used to generate various types of interfering signals for testing the performance of a receiver.
09-Jan-2007 | AN-No. 7BM50
High-speed serial interfaces often transmit data with differential signaling and differential probes that can be used to access signal traces. In addition to differential inputs, these probes have a ground connection.
02-Nov-2022
This paper explains how to use the Rohde & Schwarz IVI.NET instrument drivers in Visual Studio environment from the prospective of an occasional C# programmer in need of automating a measurement task.
31-May-2016 | AN-No. 1MA268
- not available -
20-Jul-2001 | AN-No. 7BM11