Search

Find relevant information on products, solutions or downloads quickly by using our general search: Type in a keyword, choose a category and select from the active subcategories to get what you need.

Results 1 - 10 of 22 fshz2

Did you find what you're looking for? If not, repeat the search on our International Website

  • Signal & Spectrum Analyzer - Test & Measurement

    Spectrum analyzers, signal analyzers and modulation analyzers, from handheld to top class modelsExpand allCollapse all Top ClassR&S®FSW signal and spectrum analyzerSetting standards in RF performance and usability R&S®FSW8: 2 Hz to 8 GHz R&S®FSW13: 2 Hz to 13.6 GHz R&S®FSW26: 2 Hz to 26.5 GHz R&S®FSW43: 2 Hz to 43.5 GHz R&S®FSW50: 2 Hz to 50 GHz R&S®FSW67: 2 Hz to 67 GHz R&S®FSW85: 2 Hz to 85 GHzR&

  • R&S®FSH-Z2 VSWR Bridge and Power Divider

    Key FactsThe R&S®FSH with built-in tracking generator rapidly determines the transmission characteristics of cables, filters, amplifiers, etc, with a minimum of effort.When equipped with the R&S® FSH-Z2/-Z3 VSWR bridge (10 MHz to 3 GHz/6 GHz), the R&S®FSH can also measure the matching (return loss, reflection coefficient, or VSWR) of an antenna, for example.

  • Firmware for R&S®FSH-Z2 VSWR Bridge and Power Divider

    Title Versions Last Modified File Size R&S®FSH Firmware V 14.0 08.02.20113 MB R&S®FSH Firmware Release History V 14.0 08.02.2011 155 kB R&S®FSH Firmware Release History V 14.008.02.2011155 kB Test and Measurement Division Handheld Spectrum Analyzer R&S FSH 1145.5850.03 1145.5850.13 1145.5850.23 1145.5850.06 1145.5850.26 1145.5850.18 Firmware Release History R&S FSH Page 2 of 48 Contents Firmware

  • Firmware for R&S®FSH-Z30 Spare Short/Open for R&S®FSH-Z2 for VSWR calibration

    Title Versions Last Modified File Size R&S®FSH Firmware V 14.0 08.02.20113 MB R&S®FSH Firmware Release History V 14.0 08.02.2011 155 kB R&S®FSH Firmware Release History V 14.008.02.2011155 kB Test and Measurement Division Handheld Spectrum Analyzer R&S FSH 1145.5850.03 1145.5850.13 1145.5850.23 1145.5850.06 1145.5850.26 1145.5850.18 Firmware Release History R&S FSH Page 2 of 48 Contents Firmware

  • Firmware for R&S®FSH-Z31 Spare 50 Ω Load for R&S®FSH-Z2 for VSWR and DTF calibration

    Title Versions Last Modified File Size R&S®FSH Firmware V 14.0 08.02.20113 MB R&S®FSH Firmware Release History V 14.0 08.02.2011 155 kB R&S®FSH Firmware Release History V 14.008.02.2011155 kB Test and Measurement Division Handheld Spectrum Analyzer R&S FSH 1145.5850.03 1145.5850.13 1145.5850.23 1145.5850.06 1145.5850.26 1145.5850.18 Firmware Release History R&S FSH Page 2 of 48 Contents Firmware

  • R&S®ETH Handheld TV Analyzer

    165 dBm (1 Hz) Resolution bandwidths (RBW)   100 Hz to 3 MHz in 1/3 sequence Video bandwidths   10 Hz to 3 MHz in 1/3 sequence Trace detectors   auto peak, max peak, min peak, sample, RMS Network analysis Tracking generator output level   –40 dBm to 0 dBm in 1 dB steps Data points   631 Dynamic range for transmission measurements 300 kHz to 3.6 GHz > 70 dB, typ. 90 dB Reflection measurements R&S® FSH-Z2

  • Distance-To-Fault (DTF) Measurement in 75 Ohm Systems with the R&S®FSH3-TV

    Measuring cable characteristics is important when it comes to installing and servicing cable TV systems. Cable pinches or poor connections considerably influence the characteristics of cable TV systems. This document shows how the measurement is carried out in a 75 Ohm system. The basics of distance-to-fault measurements, the test setup, calibration and measurement are discussed.

  • VSWR Measurement in 75 Ω Systems - using the R&S®FSH3-TV TV Analyzer

    The voltage standing wave ratio (VSWR) is one of the parameters in RF systems that measures the impedance mismatch. Under ideal conditions, when the load is perfectly matched to the source, the VSWR will be 1. A mismatch in the system causes reflections that will increase the VSWR and lead to losses in transmission. Although most RF components are typically designed and specified with a characteristic impedance of 50 Ω , applications and system components for cable television are designed and specified with a characteristic impedance of 75 Ω . This application note describes the measurement procedure for VSWR measurements in 75 Ω systems using the R&S®FSH3-TV handheld TV analyzer.

  • R&S FSH News, August 2006

    The R&S FSH-Z29 calibration standard is now supplied as standard together with the R&S FSH-Z2 VSWR bridge

    This download is available in the following languages:

  • R&S FSH Handheld Spectrum Analyzer - Specifications

    /-Z3 10 MHz to 3 GHz 5 MHz to 3 GHz 10 MHz to 6 GHz 5 MHz to 6 GHz Display range ± 180° (wrap) 0° to 54360° (unwrap) Group delaymeasurements (only with R&S FSH3 models 1145.5850.13 or 1145.5850.23, R&S FSH6 1145.5850.26 and R&S FSH-K2) Frequency range Reflection Transmission with R&S FSH-Z2/-Z3 10 MHz to 3 GHz 5 MHz to 3 GHz 10 MHz to 6 GHz 5 MHz to 6 GHz Aperture increments 1 to 300 Display range

    This download is available in the following languages:

Results 1 - 10 of 22
Previous  1  2  3  Next
Thank you.

Your request was successfully sent!

We will get in touch with you soon.

Your Rohde & Schwarz Team

Download

Please enter your first name.

Please enter a valid email address.

Please enter your name.

Please enter your company name.

Please enter your location.

Marketing permission
Please enter the characters shown in the image
show captcha

The input was not correct.
Content types Download types
International Website