Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
Search Rohde-Schwarz.com
Find the information you need from Rohde & Schwarz. Search for products, technologies, applications, manuals, datasheets, tutorials, FAQs, and more.
3116 Results
R&S®AC005 omnidirectional antenna – covering the frequency range from 500 MHz to 40 GHz for wideband monitoring and measuring applications.
The R&S®UAS is designed for a diverse range of antennas following customer feedback and customization by our engineers.
The ELCRODAT 6-2 protects voice and data communications in digital networks for all German and NATO security classifications.
R&S®RTO/RTE oscilloscopes support triggering and decoding of FlexRay buses, including FIBEX standard file import. Discover the FlexRay oscilloscope software.
The R&S®RTO oscilloscope supports triggering and decoding of the MIPI-RFFE protocol. Learn more about the MIPI-RFFE oscilloscope software here.
R&S®RTP, RTO and RTE oscilloscopes support decoding of 10BASE-T and 100BASE-TX Ethernet. Explore the Ethernet decoding software here.
The R&S®RTO and R&S®RTP oscilloscopes support triggering and decoding of the MIPI-RFFE protocol. Learn more about the MIPI-RFFE oscilloscope software here.
The R&S®RTO and R&S®RTE oscilloscopes support triggering and decoding of MDIO. Learn more about the MDIO triggering & decoding software here.
R&S®RTP and RTO oscilloscopes support decoding of 10BASE-T and 100BASE-TX Ethernet, as well as MDIO. Find out more about the decoding software here.
Triggering and decoding of various MIPI highspeed signals (incl. D-PHY and M-PHY) on Rohde & Schwarz RTO and RTP oscilloscopes: Decoding using intuitive menu dialogs, detailed analysis, color-coded protocol fields, table display, etc.. Trigger on errors and other protocol-specific fields.
Control unit for selecting polarization, activating or bypassing amplifiers and power supplies of rotators and selected log-periodic antennas
The R&S®RTP, R&S®RTO and R&S®RTE oscilloscopes support all data rates: high speed, full speed and low speed. Explore the triggering & decoding software here.
The R&S®RTP and RTO oscilloscopes supports triggering and decoding of USB 3.1 Gen 1 and Gen 2 signals. Explore the USB 3.1 triggering & decoding software here.
The R&S®RTO and R&S®RTE oscilloscopes support triggering and decoding of USB power delivery signals. Explore the triggering & decoding software here.
The R&S®RTO, RTE and RTH oscilloscopes support triggering and decoding of the CAN flexible data rate. Explore the CAN-FD triggering & decoding software here.
The R&S®RTO and RTE oscilloscopes support triggering & decoding of clock extension peripheral interface buses. Explore the CXPI triggering & decoding software.
R&S®RTP and RTO oscilloscopes support decoding and triggering of aerospace protocols such as MIL-STD-1553, ARINC 429, SpaceWire. Find out more about the software package here.
Many R&S oscilloscopes support triggering and decoding of ARINC 429 buses. Explore the ARINC triggering & decoding oscilloscope software here.
Choose the R&S Manchester and NRZ oscilloscope software to trigger & decode any Manchester and NRZ coded serial protocol. Explore the features now.
The R&S®RTO oscilloscope supports triggering and decoding of MIPI M-PHY physical layer and UniPro protocol layer. Learn more about the MIPI M-PHY software.
All Rohde & Schwarz oscilloscopes support triggering and decoding of UART and of RS-232, RS-422 and RS-485 buses. Learn more about the software option here.
Rohde & Schwarz RTO/RTE/RTH oscilloscopes support triggering and decoding, including symbolic decoding with the SENT software option. Learn more here.
Triggering and decoding of 8b10b and PCI Express Gen 1.1 / 2.0 / 3.0 signals on Rohde & Schwarz oscilloscopes: Decoding using intuitive menu dialogs, detailed analysis, color-coded telegrams / tables. Trigger on errors and other protocol-specific fields, such as TLP and OS.
All Rohde & Schwarz oscilloscopes support triggering and decoding of CAN and LIN buses, including CAN DBC file import. Explore the software now.
All Rohde & Schwarz oscilloscopes support triggering and decoding of I²C, of 2-wire, 3-wire and 4-wire SPI buses. Learn more about the I²C/SPI software here.
The R&S®RTO2000,; R&S®RTO6 and R&S®RTP; oscilloscopes support triggering and decoding of PCI Express Gen 1.1 and 2.0 signals. In addition, the R&S®RTP supports Gen 3.0 signals. Explore the PCIe 1.1/2.0/3.0 triggering and decoding software.
The external Frontend control software enables the operation of the external Frontends R&S FExx on the R&S RTP oscilloscope.
How to use an oscilloscope. All the basics of operating oscilloscope in one big poster - great to include in any electronic labs!
The R&S®EM200 digital compact monitoring receiver is a cost-efficient and optimized solution for remote controlled spectrum monitoring and geolocation. It detects, analyzes, demodulates and locates emissions from 8 kHz to 8 GHz.