R&S®ZN-ZE1xx Network analyzer calibration units

Automatic calibration units with two configurable ports

R&S®ZN-ZE1xx Network analyzer calibration units
Show me more details
R&S®ZN-ZE1xx Network analyzer calibration units
Show me more details
R&S®ZN-ZE1xx Network analyzer calibration units
Show me more details
R&S®ZN-ZE1xx Network analyzer calibration units
Show me more details
R&S®ZN-ZE1xx Network analyzer calibration units
Show me more details

Key facts

  • Frequency range from 5 kHz to 26.5 GHz
  • Port connectors configurable as 3.5 mm-compatible (m/f) or N-type (m/f)
  • Lightweight, rugged, portable
  • 75 years of VNAs

Economy calibration unit with a flexible configuration concept

R&S®ZN-ZE1xx calibration units combine the efficiency of automatic calibration procedures with a great price/performance ratio, and the flexibility of configuring ports as needed. All models support 3.5 mm-compatible connectors and R&S®ZN-ZE104, R&S®ZN-ZE109 and R&S®ZN-ZE118 support N-type connectors as well. Once a connector type is chosen, each individual port can be further configured as male (m) or female (f)

Features & benefits

Lowest start frequency

Frequency ranges starting from 5 kHz

The R&S®ZN-ZE1xx perfectly supports the full frequency range of the R&S®ZND, R&S®ZNL, R&S®ZNLE and R&S®ZNH with a start frequency of 5 kHZ to 26.5 GHz. The R&S®ZNA, R&S®ZNB and R&S®ZNBT are also supported.

Calibrate all port counts with each unit

Calibrate n-ports with a 2-port calibration unit

Calibrating more ports than offered by the R&S®ZN-ZE1xx is easy. A step-by-step guide helps users calibrate every port number with a two-port calibration unit, resulting in full n-port calibration.

Configurable test port types

Support for two connector system types

The ports on every R&S®ZN-ZE1xx model can be configured as 3.5 mm-compatible or N-type (not available for the R&S®ZN-ZE126). Each port can also be individually configured as male (m) or female (f).

Auto configuration and detection

Plug & play calibration

R&S®ZN-ZE1xx calibration units are automatically detected via the USB connection. All required data is transferred to the VNA. When starting calibration, connected test cables and port assignments can be found at the press of a button. Calibration requires minimal effort and time and maximum reliability.

Available models