R&S®HMC8015 Power analyzer

R&S®HMC8015 All-in-one Power Analyzer
Open Lightbox
R&S®HMC8015 All-in-one Power Analyzer, front view
Open Lightbox
R&S®HMC8015 All-in-one Power Analyzer, side view
Open Lightbox
R&S®HMC8015 All-in-one Power Analyzer, rear view
Open Lightbox
R&S®HMC8015 All-in-one Power Analyzer
Open Lightbox
R&S®HMC8015 All-in-one Power Analyzer R&S®HMC8015 All-in-one Power Analyzer, front view R&S®HMC8015 All-in-one Power Analyzer, side view R&S®HMC8015 All-in-one Power Analyzer, rear view R&S®HMC8015 All-in-one Power Analyzer

Key facts

  • Power measurement range: 50 µW to 12 kW
  • Analog bandwidth: DC to 100 kHz
  • Sampling rate: 500 ksample/s
  • Basic accuracy: 0.05 %

Starting at EUR 1,790

  • 3 year warranty

All-in-One

The compact class that has it all

The R&S®HMC8015 Power analyzer is a compact tester for AC/DC load and standby current characterization that enables measurements without additional tools such as a computer or remote infrastructure. In addition to a numerical and graphical display with 26 key parameters, the instrument delivers performance and compliance protocols in line with IEC 62301, EN 50564 and EN 61000-3-2.

Features & benefits

Policy tester

EN61000-3-2, EN50564, IEC62301

The R&S®HMC8015 Power analyzer performs automated tests in compliance with:

  • EN61000-3-2: harmonic currents for EMC, CE approval
  • EN50564: standby power consumption
  • IEC62301: standby power consumption

A step-by-step wizard guides the user through the measurement and configures the required instrument parameters. This minimizes measurement errors and makes results quickly visible. No prior knowledge of the above mentioned standards is nesseccary. After the test, a protocol is automaticlly generated.

Option/voucher HOC153/HVC153 necessary

R&S®HMC8015 Power analyzer
Open Lightbox

Typical test setup with R&S®HZC815 socket adapter

Data logging

CSV to USB or remotely via interface

  • Logging of up to 10 measurement parameters
  • Recording 10 readings per second
  • Absolute time stamps with 100ms resolution
  • Directly to USB flash drives (FAT32)
  • Logging data saved in configurable CSV format
  • Directly utilizable in Excel spreadsheets
R&S®HMC8015 Power analyzer
Open Lightbox

Logging data directly utilizable in Excel sheets

Production tester

Limit testing with PASS / FAIL

Limit testing

  • Numerical display with limit bar
  • Up to 6 limits freely configurable
  • PASS / FAIL for one limit via rear connectors
  • Analog output representing limit bar
  • Digital output showing limit violations

 
Production environment

  • Remote control via Ethernet (LXI), USB or GPIB interface
  • SCPI command set
  • Rackmount kit capability

Option/voucher HOC152/HVC152 necessary

R&S®HMC8015 Power analyzer
Open Lightbox

Huge variety of interfaces for remote control

Waveform function

Oscillographic waveform chart

  • Auto-scaling waveform
  • Automatic hardware-based triggering
  • Simultaneous display of voltage, current and power for one period
  • Auto-measurement for U(rms), I(rms), FPLL, P

Option/voucher HOC151/HVC151 necessary

R&S®HMC8015 Power analyzer
Open Lightbox

Simultaneous display of voltage, current and power for one period

Harmonic analysis

Harmonics as bar chart or table view

  • Harmonics visualized as bar chart or table view
  • Calculation covering 50 harmonics
  • Basic wave as 100% reference
  • Logarithmic display to never miss any details
  • Export function for easier report generation

Option/voucher HOC151/HVC151 necessary

R&S®HMC8015
Open Lightbox

Harmonics visualized as bar chart

Energy meter

Real-time integrator

  • High precision and gapless acquisition
  • Hardware-based, real-time integration
  • Distinguishing positive and negative Wh, Ah
  • Acquisition modes: manually, time-based, event-based (ext. trigger)
  • Logging functionality as standard

Application: Accumulated energy methods for unstable power measurements

R&S®HMC8015
Open Lightbox

High precision and gapless acquisition

Inrush measurement

  • Single shot to analyze fast switching-on operations
  • Configurable hardware trigger
  • Data export function for further analysis

Option/voucher HOC151/HVC151 necessary

R&S®HMC8015
Open Lightbox

Trend chart view showing six example switch-on operations for the DUT

Available models

Available models

  • Product Name

    R&S®HMC8015

    Order number 3593.8646.02

    Power measurement range
    50 µW to 12 kW
    Analog bandwidth
    DC to 100 kHz
    Sampling rate
    500 ksample/s
    Basic accuracy
    0.05 % of reading
    Interfaces
    LAN, USB
    Starting at
  • Product Name

    R&S®HMC8015-G

    Order number 3593.8875.02

    Power measurement range
    50 µW to 12 kW
    Analog bandwidth
    DC to 100 kHz
    Sampling rate
    500 ksample/s
    Basic accuracy
    0.05 % of reading
    Interfaces
    LAN, USB, IEEE-488 (GPIB)
    Starting at
Specifications
Specifications
Analog bandwidth   DC to 100 kHz
Frequency accuracy   0.1 % of reading
A/D converter resolution voltage and current 16 bit
Basic accuracy   0.05 % of reading
Display resolution   5 digits, 10 updates/s
Sampling frequency   500 kHz
Input impedance   2 MΩ
PLL synchronization sources   U, I, external
Filters
   Analog signal filter   1 kHz
   Digital filter depends on measurement frequency adaptive filter
   Frequency filter independent of analog signal filter 500 Hz
Additional inputs/outputs   BNC, rear panel
   Analog input   ±10 V (U peak)
   Analog input accuracy   0.5 % of reading
   Analog output   ±5 V (U peak)
Digital input
   Limits (PASS/FAIL) bandwidth 100 kHz
  PWM 1 kHz
  state ≤ 10 Hz
   Signal threshold logical zero 0 V to 2 V
  logical one 3 V to 24 V
Digital output up to 100 mA source/sink 5 V, TTL
Display   8.9 cm (3.5") TFT (color)
  resolution 320 × 240 pixel (QVGA)
Network connection AC 100 V to 115 V/230 V at 50 Hz to 60 Hz
Power consumption   max. 35 W, typ. 15 W
Operating temperature range   +5 °C to +40 °C
Storage temperature range   –25 °C to +60 °C
Standards   CAN/CSA-C22.2 NO. 61010-1, UL 61010-1,
DIN EN 61010-1, DIN EN 61326-1, DIN EN 55011
Common mode voltage   CAT II, 600 V (U RMS)
Dimensions   222 mm × 88 mm × 280 mm
(8.74 in × 3.46 in × 11.02 in)
Weight   approx. 3.25 kg (7.16 lb)
Warm-up time   60 min

Available options

General analysis
Product Description

R&S®HVC151

Order number 3622.0795.02

Description

Advanced analysis, voucher upgrade

R&S®HOC151

Order number 3622.0789.02

Description

Advanced analysis, factory direct order

R&S®HVC152

Order number 3622.3788.02

Description

Advanced I/O, voucher upgrade

R&S®HOC152

Order number 3622.3542.02

Description

Advanced I/O, factory direct order

R&S®HVC153

Order number 3622.3794.02

Description

Compliance test, voucher upgrade

R&S®HOC153

Order number 3622.3559.02

Description

Compliance test, factory direct order

Socket adapter
Product Description
R&S®HZC815

R&S®HZC815-EU

Order number 3593.8852.02

Description

Socket adapter for R&S®HMC8015, EU connector

R&S®HZC815

R&S®HZC815-GB

Order number 3622.2246.02

Description

Socket adapter for R&S®HMC8015, GB connector

R&S®HZC815

R&S®HZC815-US

Order number 3622.2252.02

Description

Socket adapter for R&S®HMC8015, US connector

R&S®HZC815

R&S®HZC815-CHN

Order number 3623.3952.02

Description

Socket adapter for R&S®HMC8015, CHN/AUS connector

Current probes
Product Description
R&S®HZC50

R&S®HZC50

Order number 3622.4690.02

Description

AC/DC current probe, 30 A, 4 mm connectors

R&S®HZC51

R&S®HZC51

Order number 3622.4684.02

Description

AC/DC current probe, 1000 A, 4 mm connectors

Rackmount kit
Product Description
19" Rackmount kit

R&S®HZC95

Order number 5800.2054.02

Description

19" Rackmount kit, 2HU,for R&S®HMC family 

Related videos

IEC 61000-3-2 Compliance test with R&S®HMC8015 Power Analyzer

A quick guide through IEC61000-3-2 compliance mesurements

29-Jan-2019

IEC62301 and EN50564 compliance test with R&S®HMC8015 power analyzer

Learn how to perform IEC62301 and EN50564 compliance tests in few easy steps

29-Jan-2019

Measuring in rush curent with R&S®HMC8015 power analyzer

Learn how to measure and conviniently save the measurement results

29-Jan-2019

Applications

Conducted Emission Limits in line with IEC/EN 61000-3-2

Automated testing of limits for harmonic current emissions (IEC 61000-3-2) using the R&S®HMC8015 Power Analyzer. A step-by-step wizard guides the user through the measurement.

More information

Standyby Power Consumption in line with IEC 62302 and EN 50564

Automated testing of standby power consumption (IEC 62301, EN 50564) using the R&S®HMC8015 Power Analyzer. A step-by-step wizard guides the user through the measurement.

More information

Measurement of Inrush Currents

Performing in-rush current measurements using the R&S®HMC8015 Power Analyzer

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

I want to receive information from Rohde & Schwarz via

Marketing permission

What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.