R&S®RTE1000 oscilloscopes

R&S®RTE1000 oscilloscope, 4 channel model
Open Lightbox
R&S®RTE1000 oscilloscope, 2 channel model
Open Lightbox
R&S®RTE1000 oscilloscope, side view
Open Lightbox
R&S®RTE1000 oscilloscope
Open Lightbox
The oscilloscope R&S®RTE
Open Lightbox
The R&S®RTE: Simply more scope
Open Lightbox
R&S®RTE1000 oscilloscope, 4 channel model R&S®RTE1000 oscilloscope, 2 channel model R&S®RTE1000 oscilloscope, side view R&S®RTE1000 oscilloscope The oscilloscope R&S®RTE

Key facts

  • Bandwidth: 200 MHz to 2 GHz
  • Sample rate: 5 Gsample/s
  • Max. memory depth: 200 Msample
  • Vertical resolution: up to 16-bit
  • MSO: 16 digital channels, optional, retrofittable

Starting at EUR 5,460

Truly uncompromized in performance

R&S®RTE1000 oscilloscopes offer a fully integrated multi-domain test solution with time, frequency, protocol and logic analysis functions. From embedded design development to power electronics analysis to general debugging, the R&S®RTE1000 handles everyday T&M challenges quickly, accurately and easily.

I    Up to 16-bit vertical resolution
I    200 Msample deep memory to analyze long sequences
I    Quickly find signal faults with 1 million waveforms/s
I    Touch-optimized operation

Features & benefits

More confidence in measurement results

  • Precise measurements due to very low inherent noise
  • Single-core A/D converter and up to 16-bit vertical resolution
  • Full measurement bandwidth, even at 500 μV/div
  • High time resolution combined with deep memory
  • Find rare signal faults quickly thanks to one million waveforms/s
  • Accurate triggering with a digital trigger system
RTE1000 Oscilloscope
Open Lightbox

See signal details with up to 16-bit vertical resolution in HD mode.

More functions and faster results

  • Automatic measurements: 77 functions
  • QuickMeas: key measurement results at the push of a button
  • History function: look back in time
  • Mask test: settings in only seconds
  • FFT function: the easy way to analyze the signal spectrum
  • Search and navigation: focus on details
RTE1000 Oscilloscope
Open Lightbox

In the R&S®RTE1000 oscilloscopes, up to eight automatic measurements can be configured and activated simultaneously.

More fun to use

  • 10.4" high-resolution touchscreen
  • Fully customizable display
  • Fast access to important tools
  • Signal details at your fingertip
  • Documentation at the push of a button
RTE1000 Oscilloscope
Open Lightbox

You can drag & drop waveforms and result windows onto the screen. The SmartGrid function makes it easy to arrange multiple diagrams or tabs on the screen.

Engineered for multi-domain challenges

  • Logic analysis: fast and precise testing of embedded designs
  • Serial protocols: easy triggering and decoding
  • Power analysis
  • Spectrum analysis
  • EMI debugging: testing during development
  • Integrated arbitrary waveform generator
RTE1000 Oscilloscope
Open Lightbox

The mixed signal option turns the R&S®RTE1000 oscilloscopes into an easy-to-use mixed signal oscilloscope (MSO) with 16 digital channels.

Available models
Product Name
Bandwidth
Channels
Sample Rate
Max. Memory Depth
Optional MSO
Starting at
R&S®RTE1022

Order number 1326.2000.22

Bandwidth
200 MHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1024

Order number 1326.2000.24

Bandwidth
200 MHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1032

Order number 1326.2000.32

Bandwidth
350 MHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1034

Order number 1326.2000.34

Bandwidth
350 MHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1052

Order number 1326.2000.52

Bandwidth
500 MHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1054

Order number 1326.2000.54

Bandwidth
500 MHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1102

Order number 1326.2000.62

Bandwidth
1 GHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1104

Order number 1326.2000.64

Bandwidth
1 GHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1152

Order number 1326.2000.72

Bandwidth
1.5 GHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1154

Order number 1326.2000.74

Bandwidth
1.5 GHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1202

Order number 1326.2000.82

Bandwidth
2 GHz
Channels
2
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
R&S®RTE1204

Order number 1326.2000.84

Bandwidth
2 GHz
Channels
4
Sample Rate
5 Gsample/s
Max. Memory Depth
200 Msample
Optional MSO
16 digital channels
Starting at
Specifications
Vertical system
Number of channels R&S®RTE1022/R&S®RTE1032/ R&S®RTE1052/R&S®RTE1102/ R&S®RTE1152/R&S®RTE1202 2
  R&S®RTE1024/R&S®RTE1034/ R&S®RTE1054/R&S®RTE1104/ R&S®RTE1154/R&S®RTE1204 4
Analog bandwidth (–3 dB) at 50 Ω R&S®RTE1022/R&S®RTE1024 ≥ 200 MHz
  R&S®RTE1032/R&S®RTE1034 ≥ 350 MHz
  R&S®RTE1052/R&S®RTE1054 ≥ 500 MHz
  R&S®RTE1102/R&S®RTE1104 ≥ 1 GHz
  R&S®RTE1152/R&S®RTE1154 ≥ 1.5 GHz
  R&S®RTE1202/R&S®RTE1204 ≥ 2 GHz
Rise time R&S®RTE1022/R&S®RTE1024 < 1.75 ns
  R&S®RTE1032/R&S®RTE1034 < 1 ns
  R&S®RTE1052/R&S®RTE1054 < 700 ps
  R&S®RTE1102/R&S®RTE1104 < 350 ps
  R&S®RTE1152/R&S®RTE1154 < 233 ps
  R&S®RTE1202/R&S®RTE1204 < 175 ps
Impedance   50 Ω ± 1,5 %, 1 MΩ ± 1 % || 16 pF  ± 1 pF (meas.)
Input sensitivity max. bandwidth in all ranges 50 Ω: 500 μV/div to 1 V/div
1 MΩ: 500 μV/div to 10 V/div
Resolution   8 bit (7-bit ENOB)
  with high definition mode 16 bit
Acquisition system
Realtime sampling rate   max. 5 Gsample/s on each channel
Acquisition memory standard configuration,
per channel/1 channel active
R&S®RTE1000 2-channel model: 10/20 Msample
R&S®RTE1000 4-channel model: 10/40 Msample
  max. upgrade (R&S®RTE-B102 option),
per channel/1 channel active
R&S®RTE1000 2-channel model: 50/100 Msample
R&S®RTE1000 4-channel model: 50/200 Msample
Acquisition rate   > 1 000 000 waveforms/s
Decimation modes any combination of decimation mode and waveform arithmetics sample, peak detect, high resolution,
root mean square
Waveform arithmetics   off, envelope, average
Horizontal system
Timebase range   50 ps/div to 5000 s/div
Timebase accuracy after delivery/calibration ±2 ppm
Channel deskew   ±100 ns
Trigger system
Trigger types   edge, glitch, width, runt, window, timeout, interval, slew rate, data2clock, pattern, state, serial pattern, TV/video, serial bus trigger (optional)
Sensitivity definition of trigger hysteresis can be set automatically or manually from 0 div to 5 div
Analysis and measurement functions
Automated measurements   77 measurement functions
Cursor measurements   2 cursor sets, each consisting of two horizontal and two vertical cursors
Waveform mathematics   4 math waveforms;
mathematics, logical operations, comparison, FIR filter, FFT
MSO option
Digital channels   16 (2 logic probes)
Input impedance   100 k || 4 pF
Sampling rate   5 Gsample/s per channel
Acquisition memory   100 Msample per channel
Parallel buses   up to 4
General data
Dimensions W x H x D 427 mm × 249 mm × 204 mm
(16.81 in × 9.8 in × 8.03 in)
Weight without options, nominal 8,6 kg (18.96 lb)
Screen   10.4" LC TFT color touchscreen,
1024 × 728 pixel (XGA)
Interfaces   1 Gbit/s LAN, 4 × USB 2.0, GPIB (optional), DVI for external monitor, external trigger, trigger output

Available options

General
Product
Description
RTE-B1-Digital-Oscilloscope_mt_01.jpg

Order number 1326.3570.02

Description
Mixed signal option, 400 MHz, 5 Gsample/s, 16 channels, 100 Msample per channel
Adds 16 digital channels to R&S®RTE1000 oscilloscopes.
R&S®RTE-B1E

Order number 1333.0750.02

Description
Digital Extension Port for R&S®RTE
Required for R&S®RT-ZVC02 and R&S®RT-ZVC04 Hardware. Included in R&S®RTE-B1
RTE-B6-Digital_Oscilloscopes_img.jpg

Order number 1326.3012.02

Description
Arbitrary waveform generator
Add 2-channel 500 Msample/s waveform generator and 8-channel pattern generator
GPIB Interface
R&S®RTE-B10

Order number 1317.4978.02

Description
GPIB interface
Replacement SSD, incl. firmware
R&S®RTE-B18

Order number 1317.7002.02

Description
Replacement SSD, incl. firmware
SSD comes pre-installed with operating system and scope application
Memory upgrade
Product
Description
R&S®RTE-B101
Description
Memory upgrade to 20 Msample
Memory upgrade to 20 Msample per channel (standard for R&S®RTE with SN ≥ 300000)
R&S®RTE-B102
Description
Memory upgrade to 50 Msample
Memory upgrade to 50 Msample per channel (standard for R&S®RTE with SN ≥ 300000)
Bandwidth upgrade
Product
Description
Bandwidth Upgrade
R&S®RTE-B200

Order number 1326.1384.02

Description
Bandwidth upgrade of the R&S®RTE1022/4 to 350 MHz bandwidth, incl. calibration
Bandwidth Upgrade
R&S®RTE-B201

Order number 1326.1390.02

Description
Bandwidth upgrade of the R&S®RTE1022/4 to 500 MHz bandwidth, incl. calibration
Bandwidth Upgrade
R&S®RTE-B202

Order number 1326.1403.02

Description
Bandwidth upgrade of the R&S®RTE1022/4 to 1 GHz bandwidth, incl. calibration
Bandwidth
R&S®RTE-B203

Order number 1326.1410.02

Description
Bandwidth upgrade of the R&S®RTE1022/4 to 1.5 GHz bandwidth, incl. calibration
Bandwidth
R&S®RTE-B204

Order number 1326.1426.02

Description
Bandwidth upgrade of the R&S®RTE1022/4 to 2 GHz bandwidth, incl. calibration
Bandwidth
R&S®RTE-B205

Order number 1326.1432.02

Description
Bandwidth upgrade of the R&S®RTE1032/4 to 500 MHz bandwidth, incl. calibration
Bandwidth
R&S®RTE-B206

Order number 1326.1449.02

Description
Bandwidth upgrade of the R&S®RTE1032/4 to 1 GHz bandwidth, incl. calibration
Bandwidth
R&S®RTE-B207

Order number 1326.1455.02

Description
Bandwidth upgrade of the R&S®RTE1032/4 to 1.5 GHz bandwidth, incl. calibration
Bandwidth
R&S®RTE-B208

Order number 1326.1461.02

Description
Bandwidth upgrade of the R&S®RTE1032/4 to 2 GHz bandwidth, incl. calibration
Bandwidth upgrade
R&S®RTE-B209

Order number 1326.1478.02

Description
Bandwidth upgrade of the R&S®RTE1052/4 to 1 GHz bandwidth, incl. calibration
Bandwidth.svg
R&S®RTE-B210

Order number 1326.1484.02

Description
Bandwidth upgrade of the R&S®RTE1052/4 to 1.5 GHz bandwidth, incl. calibration
Bandwidth upgrade
R&S®RTE-B211

Order number 1326.1490.02

Description
Bandwidth upgrade of the R&S®RTE1052/4 to 2 GHz bandwidth, incl. calibration
Bandwidth upgrade
R&S®RTE-B212

Order number 1326.1503.02

Description
Bandwidth upgrade of the R&S®RTE1102/4 to 1.5 GHz bandwidth, incl. calibration
Bandwidth upgrade
R&S®RTE-B213

Order number 1326.1510.02

Description
Bandwidth upgrade of the R&S®RTE1102/4 to 2 GHz bandwidth, incl. calibration
Bandwidth upgrade
R&S®RTE-B214

Order number 1326.1526.02

Description
Bandwidth upgrade of the R&S®RTE1152/4 to 2 GHz bandwidth, incl. calibration
Serial triggering and decoding
Product
Description
RTE-K1 - I²C/SPI Serial Triggering and Decoding

Order number 1326.1178.02

Description
I²C/SPI triggering and decoding
Oscilloscope - UART/RS232/422/485 Serial Triggering and Decoding

Order number 1326.1184.02

Description
UART/RS-232 triggering and decoding
Oscilloscope - CAN/LIN Serial Triggering and Decoding

Order number 1326.1190.02

Description
CAN/LIN triggering and decoding
Oscilloscope FlexRay™ Serial Triggering and Decoding

Order number 1326.1203.02

Description
FlexRay™ triggering and decoding
RTE-K5 - I²S/LJ/RJ/TDM Serial Triggering and Decoding

Order number 1326.1210.02

Description
I²S/LJ/RJ/TDM triggering and decoding
Oscilloscope MIL-1553 Serial Triggering and Decoding

Order number 1326.1226.02

Description
MIL-1553 triggering and decoding
ARINC 429

Order number 1326.1232.02

Description
ARINC 429 triggering and decoding
10/100BASE-T Ethernet Serial Decoding

Order number 1326.1332.02

Description
Ethernet serial decoding
RTEK9_canfd_110.jpg

Order number 1326.1249.02

Description
CAN-FD triggering and decoding
RTE-K10_Oscilloscope_screen01.jpg

Order number 1323.1603.02

Description
SENT triggering and decoding
Bus analysis

Order number 1801.2852.02

Description
Bus analysis
RTE-K50_Digital-Oscilloscope_15.jpg

Order number 1326.1326.02

Description
MANCHESTER/NRZ triggering and decoding
RTEK55_MDIO_01.jpg

Order number 1326.1255.02

Description
MDIO triggering and decoding
Oscilloscope 100Base-T1 Serial Triggering and Decoding

Order number 1333.0615.02

Description
100BASE-T1 triggering and decoding
Oscilloscope USB 1.0/1.1/2.0/HSIC Triggering and Decoding

Order number 1326.1610.02

Description
USB 1.0/1.1/2.0/HSIC triggering and decoding
Oscilloscope USB Power Delivery Triggering and Decoding

Order number 1326.3158.02

Description
USB-PD triggering and decoding
Oscilloscope SpaceWire Serial Triggering and Decoding

Order number 1326.2845.02

Description
SpaceWire triggering and decoding
CXPI triggering and decoding

Order number 1326.3193.02

Description
CXPI triggering and decoding
General analysis
Product
Description
Oscilloscope High Definition Mode

Order number 1326.1261.02

Description
High definition mode
Oscilloscope Spectrum Analysis

Order number 1326.3006.02

Description
Spectrum analysis
Oscilloscope Power Analysis

Order number 1326.1278.02

Description
Power analysis
Windows upgrade
Product
Description
R&S®RTE-U2

Order number 1802.9296.02

Description
Upgrade to Windows 10 (includes new PC and Windows 10 license)
R&S®RTE-U2A

Order number 1802.9338.02

Description
Upgrade to Windows 10 (includes new PC, new SSD and Windows 10 license)
Accessories
Product
Description
RTO-Z1 Front Cover
R&S®RTO-Z1

Order number 1333.0096.02

Description
Front cover
Protects the front of the R&S®RTO2000/R&S®RTE1000 oscilloscope
RTO-Z3 Soft Case
R&S®RTO-Z3

Order number 1304.9118.02

Description
Soft case
Stores the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories
RTO-Z4 Transit case
R&S®RTO-Z4

Order number 1317.7025.02

Description
Transit case
Protects the R&S®RTO2000/R&S®RTE1000 oscilloscope and accessories during transport
RTO-Z5 Probe Case
R&S®RTO-Z5

Order number 1317.7031.02

Description
Probe pouch for R&S®RTO2000 and R&S®RTE1000 oscilloscopes
ZZA-RTO 19" Rackmount Adapter
R&S®ZZA-RTO

Order number 1304.8286.00

Description
19" Rackmount adapter
For mounting R&S®RTO2000/R&S®RTE1000 oscilloscopes in a standard 6 HU 19" rack
R&S®Z2T Probe adapter
R&S®RT-Z2T

Order number 1338.0007.02

Description
Probe adapter
Enables Tek’s TekProbe-BNC level 2 probes to connect to Rohde & Schwarz probe interface
Passive probes
Product
Description
 RT-ZP10 Passive probe

Order number 1409.7550.00

Description
Passive probe, 500 MHz, 10:1
Active single-ended probes
Product
Description
RT-ZS10 Active single-ended probe

Order number 1410.4080.02

Description
Active single-ended probe, 1 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
RT-ZS10E Active single-ended probe

Order number 1418.7007.02

Description
Active single-ended probe, 1 GHz, Rohde & Schwarz probe interface
RT-ZS20 Active single-ended probe

Order number 1410.3502.02

Description
Active single-ended probe, 1.5 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
RT-ZS30 Active single-ended probe

Order number 1410.4309.02

Description
Active single-ended probe, 3 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Active differential probes
Product
Description
RT-ZD10 Active differential probe

Order number 1410.4715.02

Description
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
Active differential probe, 1 GHz, Rohde & Schwarz probe interface
R&S®RT-ZD20 Active differential probe

Order number 1410.4409.02

Description
Active differential probe, 1.5 GHz, Rohde & Schwarz probe interface
RT-ZD30 Active differential probe

Order number 1410.4609.02

Description
Active differential probe, 3.0 GHz, Rohde & Schwarz probe interface
Modular probe system
Product
Description
RT-ZM15

Order number 1800.4700.02

Description
Modular probe amplifier module, 1.5 GHz
RT-ZM30

Order number 1419.3005.02

Description
Modular probe amplifier module, 3 GHz
RT-ZMA10_Solder-In_Tip_Module_img.jpg
R&S®RT-ZMA10

Order number 1419.4301.02

Description
Solder-in probe tip cable for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
RT-ZMA10_Solder-In_Tip_Module_img.jpg
R&S®RT-ZMA10-6

Order number 1801.4349.02

Description
Set 6x solder-in probe tip cable for R&S®RT-ZM modular probe system
>16 GHz, < 28 ps, probe tip module, P/N/DM/CM
RT-ZMA11
R&S®RT-ZMA11

Order number 1419.4318.02

Description
Solder-in probe tip cable with ext. temp. range for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
RT-ZMA12_Solder-In_Tip_Module_img.jpg
R&S®RT-ZMA12

Order number 1419.4324.02

Description
Square-pin probe tip module for R&S®RT-ZM modular probe system
> 6 GHz, < 75 ps, probe tip module, P/N/DM/CM
RT-ZMA15_Solder-In_Tip_Module_img.jpg
R&S®RT-ZMA15

Order number 1419.4224.02

Description
Quick connect probe tip module for R&S®RT-ZM modular probe system
> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM
RT-ZMA30
R&S®RT-ZMA30

Order number 1419.4353.02

Description
Browser module for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, DM
RT-ZMA40_SMA_Module_img.jpg
R&S®RT-ZMA40

Order number 1419.4201.02

Description
SMA module for R&S®RT-ZM modular probe system
> 16 GHz, < 28 ps, probe tip module, P/N/DM/CM
RT-ZMA50
R&S®RT-ZMA50

Order number 1419.4218.02

Description
Temperature kit for R&S®RT-ZM modular probe system
> 12 GHz, < 37 ps, probe tip module, P/N/DM/CM
Power rail probes
Product
Description
RT-ZPR20 Power rail probes

Order number 1800.5006.02

Description
Power rail probe, 2 GHz, R&S®ProbeMeter, Rohde & Schwarz probe interface
Multi-channel power probes
Product
Description
RT-ZVC Multi-channel power probe

Order number 1326.0259.02

Description
Multi-channel power probe
1 MHz, 5 Msample/s, 18-bit, 2 current inputs, 2 voltage inputs
 Multi-Channel Power Probe

Order number 1326.0259.04

Description
Multi-channel power probe
1 MHz, 5 Msample/s, 18-bit, 4 current inputs, 4 voltage inputs
High voltage probes
Product
Description
RT-ZH03 - 250 MHz Passive high voltage probe

Order number 1333.0873.02

Description
250 MHz passive high voltage probe
RT-ZH10 High voltage probe

Order number 1409.7720.02

Description
400 MHz passive high voltage probe
RTZH10_front.jpg

Order number 1409.7737.02

Description
400 MHz passive high voltage probe
RT-ZD01 High voltage probe

Order number 1422.0703.02

Description
100 MHz high voltage differential probe
RT-ZD02 Active differential probe, 200 MHz, BNC interface

Order number 1333.0821.02

Description
Active differential probe, 200 MHz, BNC interface
RTZD08 Active differential probe, 800 GHz, BNC interface

Order number 1333.0838.02

Description
Active differential probe, 800 GHz, BNC interface
RT-ZHD15 High voltage probe

Order number 1800.2107.02

Description
100 MHz high voltage differential probe
RT-ZHD16 200 MHz High voltage differential probe

Order number 1800.2207.02

Description
200 MHz high voltage differential probe
RT-ZHD60 High voltage probe

Order number 1800.2007.02

Description
100 MHz high voltage differential probe
25 MHz High voltage differential probe

Order number 1337.9700.02

Description
25 MHz high voltage differential probe
25 MHz High voltage differential probe

Order number 1337.9800.02

Description
25 MHz high voltage differential probe
Current probes
Product
Description
RT-ZC02 AC/DC 20 KHZ Current probe

Order number 1333.0850.02

Description
AC/DC 20 kHz current probe
RT-ZC03 100 KHZ Current probe

Order number 1333.0844.02

Description
100 kHz current probe
RT-ZC05B 2 MHz Current probe

Order number 1409.8204.02

Description
2 MHz current probe
RT-ZC10 10 MHz Current probe

Order number 1409.7750K02

Description
10 MHz current probe
RT-ZC10B 10 MHz Current probe

Order number 1409.8210.02

Description
10 MHz current probe
RT-ZC15B 50 MHz Current probe

Order number 1409.8227.02

Description
50 MHz current probe
RT-ZC20 20 MHz Current probe

Order number 1409.7766K02

Description
100 MHz current probe
RT-ZC20B 100 MHz Current probe

Order number 1409.8233.02

Description
100 MHz current probe
RT-ZC30 120 MHz Current probe

Order number 1409.7772K02

Description
120 MHz current probe
R&S®RT-ZC31

Order number 1801.4932.02

Description
120 MHz current probe
EMC near-field probes
Product
Description
HZ15_front.jpg

Order number 1147.2736.02

Description
E and H near-field probe set
Application bundles
Product
Description
Trigger and Decode Bundle Option

Order number 1326.4190.02

Description
Trigger and decode bundle option
Decode more than 28 serial protocols with the R&S®RTE trigger and decode software bundle. T&D bundle includes I²C/SPI, UART/RS232, CAN/LIN, FlexRay, I²C, MIL, ARINC, Ethernet, CAN-FD, SENT, Custom, MDIO, USB2.0, USB-PD, SpaceWire, CXPI

RTE1000 - Media center

Power Integrity - capture 1

The quality of the power supply is a key factor in the functionality and performance of sensitive electronic circuits.

19-May-2018

R&S®Multi-domain debugging of embedded IoT devices

This video demonstrates the multi-domain test capabilities of Rohde & Schwarz oscilloscopes.

09-Mar-2018

Power Integrity - capture 2

5 tips on how to make more precise measurements

07-Mar-2018

R&S®RTE - Tutorial: Toolbar

Basic introduction to the operation of the toolbar functionality.

15-Feb-2018

R&S®RTE - Tutorial: Histogram

Basic introduction to the operation of the histogram functionality.

15-Feb-2018

R&S®RTE - Tutorial: Mask Test

Basic introduction to the operation of the mask test functionality.

15-Feb-2018

R&S®RTE - Tutorial: Smart Grid

Basic introduction to the operation of the smart grid functionality.

15-Feb-2018

R&S®RTE - Tutorial: Zoom

Basic introduction to the operation of the zoom functionality.

15-Feb-2018

RTE Application videos - Media center

Possibilities provided by the I²C decode protocol

Dive into your protocol to check for any problems with your I²C interface.

13-Feb-2020

The right set up to Decode I²C with an oscilloscope

Discover how to easily decode I²C with the right setup, as shown on an R&S®RTO.

13-Feb-2020

I²C Debugging with hardware trigger of RTO

How to identify and trace down errors in I²C interfaces using the Hardware Trigger together with History Mode.

13-Feb-2020

In depth analysis of your RS232 interface

In depth analysis of RS232 interfaces frame by frame using the R&S®RTO decode table and zoom window.

13-Feb-2020

Debug RS232, RS485 or UART interfaces

Let your Oscilloscope decode your UART/RS232/RS485 interfaces for you! So you can quickly understand the data and correlate the data content with the electrical signal.

13-Feb-2020

UART/RS232/RS485 Triggering on Break condition

Use the hardware trigger to isolate break conditions. Break conditions can be corellated with their root cause one by one using the History Mode.

13-Feb-2020

Power Integrity - capture 1

The quality of the power supply is a key factor in the functionality and performance of sensitive electronic circuits.

19-May-2018

R&S®Multi-domain debugging of embedded IoT devices

This video demonstrates the multi-domain test capabilities of Rohde & Schwarz oscilloscopes.

09-Mar-2018

10 years of R&S oscilloscopes

No compromises and excellent quality - made by Rohde & Schwarz

10 years ago we expanded our measurement technology portfolio with the launch of R&S®RTO1000 and R&S®RTM1000. 10 years later, two product families have become eight: from entry-level and handheld to high-end instruments. Before we started, our engineers have taken a very close look at what doesn't fit on the instruments that are already on the market - and have made it better.Celebrate with us our 10th birthday and take part in our contest.

Oscilloscopes promotion

Oscilloscopes promotion

Rohde & Schwarz Oscilloscopes over 50% off, now through March 31st, 2021

Solution for

Oscilloscope portfolio

Oscilloscopes

More information

Oscilloscope software

More information

Oscilloscope probes

More information

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

I want to receive information from Rohde & Schwarz via

Marketing permission

What does this mean in detail?

I agree that Rohde & Schwarz GmbH & Co. KG and the Rohde & Schwarz entity or subsidiary company mentioned in the imprint of this website, may contact me via the chosen channel (email or postal mail) for marketing and advertising purposes (e.g. information on special offers and discount promotions) related to, but not limited to, products and solutions in the fields of test and measurement, secure communications, monitoring and network testing, broadcast and media, and cybersecurity.

Your rights

This declaration of consent may be withdrawn at any time by sending an email with the subject "Unsubscribe" to news@rohde-schwarz.com. Additionally, a link to unsubscribe from future email advertisements is contained in each email sent. Further details on the use of personal data and the withdrawal procedure are set out in the Statement of Privacy.

Your request has been sent successfully. We will contact you shortly.
An error is occurred, please try it again later.
General and legal information

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

Terms & Conditions of the Prize Draw 10 years Rohde & Schwarz oscilloscopes

1. The prize draw “10 years Rohde & Schwarz oscilloscopes” (herein referred to as “Draw”) is organized by Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Munich, Germany, Tel. +49 89 41 29 0 (herein referred to as “R&S).

2. All participators can register to the draw during January 01, 2020 to December 31, 2020 with their name, company name and business e-mail.

3. Participation is free of charge and not dependent on the purchase of goods or services.

4. The draw is only open to legal entities and only the legal entities are able to win the prizes. An individual person is not allowed to participate on its own name and its own account but as a representative of a legal entity filing the participation form in the name of and on behalf of the legal entity.

5. The prizes to win are 1 of 10 R&S®RTB2000 within the time frame January 1, 2020 to December 31, 2020:

Prize: 1x R&S®RTB2000 Digital Oscilloscope

6. The draw takes place at Rohde & Schwarz headquarters, Muehldorstrasse 15, 81671 Munich. The winner of the prizes will be informed by e-mail within 5 (5) working days.

7. The authorized representative of the legal entity shall inform Rohde & Schwarz about the acceptance of the price. In case of the denial of the acceptance, or no answer within two (2) weeks, a new winner will be drawn. If no winner can be determined within four (4) weeks, the draw ends and the prize forfeit.

8. R&S’ employees and members of their families and also person being familiar with the process of the draw and members of their families are excluded from filling the participation form.

9. No cash equivalent or exchange of prizes is allowed. Prizes are non-transferable. All taxes, levies, duties, fees and other charges levied in the participant´s country shall be borne by the participant.

10. Personal data will be processed only for the purpose of this prize draw and deleted four (4) weeks after the draw, if not agreed otherwise.

11. Any Participant who does not comply with these Terms & Conditions may be disqualified by R&S from this Competition. In such cases, prizes can also be withdrawn retrospectively. In case a prize is withdrawn retrospectively due to the non-compliance with these Terms & Conditions, it shall be returned by the respective participant at his cost to R&S’ address mentioned under Nr.1 and a new winner will be drawn.

12. The participants cannot claim the prizes of this draw and no legal recourse is permitted in this respect.

13. The draw and any contractual relationship arising therefrom between R&S and the respective participant shall be governed by and construed in accordance with the laws of Germany, without any recourse to the conflict of laws. The courts of Munich, Germany, shall have exclusive jurisdiction in case of any disputes arising directly or indirectly from the participation in this Competition.