<?xml version="1.0" encoding="utf-8"?>
<rss xmlns:atom="http://www.w3.org/2005/Atom" version="2.0">
    <channel>
        <atom:link href="https://www.rohde-schwarz.com/in/rss-feeds/application-note-feed_229508.rss" rel="self" type="application/rss+xml"/>

        <title>Rohde &amp; Schwarz Application Note Feed</title>
        <link>https://www.rohde-schwarz.com</link>

        <copyright>(C) Rohde &amp; Schwarz RSS-Feeds</copyright>

        <description> All new and updated application notes will be delivered to your feed reader.</description>
        <language>en</language>
        <docs>http://blogs.law.harvard.edu/tech/rss</docs>
        <ttl>30</ttl>
        <image>
            <title>Rohde &amp; Schwarz Application Note Feed</title>
            <link>https://www.rohde-schwarz.com</link>
            <url>https://cdn.rohde-schwarz.com/pws/_tech/images/img_static/r-s-logo-ie6.gif</url>
        </image>
        <item>
    <title>Harmonics and flicker compliance testing in line with IEC/EN 61000-3-2 and IEC/EN 61000-3-3</title>
    <link>https://www.rohde-schwarz.com/in/applications/harmonics-and-flicker-compliance-testing-in-line-with-iec-en-61000-3-2-and-iec-en-61000-3-3_56279-1712384.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/harmonics-and-flicker-compliance-testing-in-line-with-iec-en-61000-3-2-and-iec-en-61000-3-3_56279-1712384.html</guid>
    <description><![CDATA[
    Modern electronics often generates current and voltage distortions that interfere with the 50 Hz/60 Hz mains. Without intervention, these distortions degrade power quality and can compromise the stability of the electrical network. The LMG600 power analyzer series provides a turnkey compliance test solution for harmonic current emissions and voltage flicker.
    ]]></description>
    <pubDate>Tue, 3 Nov 2026 07:54:21 +0000</pubDate>
</item>
<item>
    <title>Measurement Accuracy Verification Tool for R&amp;S® HMC8012 AND UDS</title>
    <link>https://www.rohde-schwarz.com/in/applications/measurement-accuracy-verification-tool-for-rs-hmc8012-and-uds_56280-1708868.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/measurement-accuracy-verification-tool-for-rs-hmc8012-and-uds_56280-1708868.html</guid>
    <description><![CDATA[
    The R&amp;S®HMC8012, R&amp;S®UDS500 and R&amp;S®UDS600 digital multimeters support a wide range of electrical measurement functions. The permissible measurement error depends on the selected function and measurement range, the value indicated by the instrument, the signal frequency for AC measurements and the ambient temperature. Manually applying the corresponding accuracy tables can therefore be time-consuming and may lead to calculation or range-selection errors.This application note describes the Measurement Accuracy Verification Tool, a Windows desktop application developed to simplify and standardize this evaluation. The user selects the digital multimeter, measurement function, range and input unit, and then enters the reference value, the value indicated by the multimeter and the ambient temperature. For AC measurements, the applicable signal frequency and optional crest-factor contribution can also be specified.The application automatically selects the relevant instrument-specific accuracy coefficients and calculates the contributions related to the indicated value, selected range and temperature deviation. It then determines the minimum and maximum permitted values around the multimeter indication and compares the reference value with this interval. The result is displayed as a clear PASS or FAIL decision together with the calculated limits and any relevant notes or warnings.The tool can be used for manual measurement verification and calibration support. It does not communicate directly with the instruments and does not replace a calibrated reference standard or the procedures specified in the applicable instrument documentation.
    ]]></description>
    <pubDate>Wed, 28 Oct 2026 11:30:06 +0000</pubDate>
</item>
<item>
    <title>Precisely measure power in three-phase and multi-phase systems</title>
    <link>https://www.rohde-schwarz.com/in/applications/precisely-measure-power-in-three-phase-and-multi-phase-systems_56279-1700481.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/precisely-measure-power-in-three-phase-and-multi-phase-systems_56279-1700481.html</guid>
    <description><![CDATA[
    Modern power electronics rely more and more on multi-phase systems. While such configurations improve performance, the higher number of phases complicates measurement and evaluation and can cause production and testing bottlenecks.
    ]]></description>
    <pubDate>Tue, 13 Oct 2026 13:08:28 +0000</pubDate>
</item>
<item>
    <title>Measure noise spectral density with oscilloscopes</title>
    <link>https://www.rohde-schwarz.com/in/applications/measure-noise-spectral-density-with-oscilloscopes_56279-1692992.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/measure-noise-spectral-density-with-oscilloscopes_56279-1692992.html</guid>
    <description><![CDATA[
    Noise spectral density (NSD) describes the amplitude of random noise per bandwidth unit of a signal. NSD is expressed as a voltage value divided by the square root of frequency and is similar to power spectral density (PSD) which equals power of the noise per Hz. An oscilloscope with a high resolution FFT engine and flexible math channels can be used to extract NSD directly from a time domain acquisition, without a separate spectrum analyzer or a dedicated noise figure instrument.
    ]]></description>
    <pubDate>Tue, 29 Sep 2026 11:24:15 +0000</pubDate>
</item>
<item>
    <title>Digital DC Meter Testing</title>
    <link>https://www.rohde-schwarz.com/in/applications/digital-dc-meter-testing_56280-1691009.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/digital-dc-meter-testing_56280-1691009.html</guid>
    <description><![CDATA[
    The advancing expansion of DC grids, the integration of DC microgrids, and the proliferation of DC charging stations for electric vehicles - where the DC energy transferred needs to be accurately measured for accounting purposes - are all driving the demand for DC meters. As soon as the meter readings become the base for billing, the consumers have a vested interest in the DC meter&#039;s reliability and precision. It becomes a matter of trust to ensure proper verification, calibration and certification of the DC meter used (e.g. Eichrecht conformity resp. E-VDE-AR-E 2418-3-100).
    ]]></description>
    <pubDate>Fri, 25 Sep 2026 12:41:18 +0000</pubDate>
</item>
<item>
    <title>Measuring Standby Power and Energy Efficiency</title>
    <link>https://www.rohde-schwarz.com/in/applications/measuring-standby-power-and-energy-efficiency_56280-1690891.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/measuring-standby-power-and-energy-efficiency_56280-1690891.html</guid>
    <description><![CDATA[
    While fossil fuel reserves are constantly decreasing, the costs of energy are on the rise. Saving energy becomes increasingly important for consumers’ buying decisions. One area with a big potential for energy savings is consumer electronics operating in standby mode, since they still drain power from the grid. Whereas every single device only consumes a few watts, the overall energy consumption is considerable.For several years, power input gets optimized both in normal operation and standby. Standards like EnergyStar, EuP (Energy using Products, directive 2005/32/EU in conjunction with regulation 1275/2008) and others, as well as norms like IEC 62301:2011 or EN 50564:2011 define maximum power input along with the setup for measuring it.
    ]]></description>
    <pubDate>Fri, 25 Sep 2026 12:31:18 +0000</pubDate>
</item>
<item>
    <title>Magnetic Characterization of Transformer Materials</title>
    <link>https://www.rohde-schwarz.com/in/applications/magnetic-characterization-of-transformer-materials_56280-1690817.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/magnetic-characterization-of-transformer-materials_56280-1690817.html</guid>
    <description><![CDATA[
    Precision loss power measurement of sheet iron and ferrite cores with high signal frequency: exact, easy and in real-time! With the ZES ZIMMER – A Rohde &amp; Schwarz Company – precision power analyzer LMG611 and other LMG models it is possible to obtain the magnetic characteristics of transformer-cores and coil materials besides a precise measurement of power loss.Those could be the peak values of the magnetic flux, the magnetic field strength and the permeability of a core which are determined at low and at high frequencies. For the quality control of magnetic materials completely wound cores can be used.Many measuring proceedings require sinusoidal field strength or flux which require expensive and complicated signal sources. Since the main point of interest is especially the saturation interval, there will be a high demand for the source in this range. It is more elegant and cheaper to use &quot;intelligent&quot; measuring equipment and allow arbitrary curve forms of the voltage and the current and to apply some mathematics. In doing so low-cost power sources can be used. Even the line voltage with its high harmonic distortion can be used.
    ]]></description>
    <pubDate>Fri, 25 Sep 2026 12:18:09 +0000</pubDate>
</item>
<item>
    <title>Industry Power Performance Benchmarking of Data Centers</title>
    <link>https://www.rohde-schwarz.com/in/applications/industry-power-performance-benchmarking-of-data-centers_56280-1690628.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/industry-power-performance-benchmarking-of-data-centers_56280-1690628.html</guid>
    <description><![CDATA[
    In today’s energy-conscious world, optimizing power efficiency in data centers has become a key focus for IT infrastructure. As the demand for data processing grows, data centers are consuming more energy, making energy efficiency in server operations a critical factor in evaluating server performance in the modern tech landscape. As a result, the need to effectively measure and benchmark power consumption to optimize server energy efficiency is more pressing than ever.
    ]]></description>
    <pubDate>Fri, 25 Sep 2026 12:03:58 +0000</pubDate>
</item>
<item>
    <title>LMG600 Series Application: Transformers</title>
    <link>https://www.rohde-schwarz.com/in/applications/lmg600-series-application-transformers_56280-1690496.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/lmg600-series-application-transformers_56280-1690496.html</guid>
    <description><![CDATA[
    The efficiency of power transformers is a key factor in reducing energy losses within the power distribution network, not to mention the increasing regulatory pressure from energy-consuming facilities such as data centers. Inefficiencies in power transmission result in financial losses and elevated greenhouse gas emissions, both of which must be avoided. As part of type and acceptance testing, power transformers are both specified with respect to their essential electrical parameters and subsequently tested and certified for compliance with these and other regulatory requirements. High efficiency and full conformity are the ultimate objectives. To achieve this, all relevant electrical performance parameters must be measured and analyzed with the highest precision. In addition, manufacturers are increasingly required to perform special tests tailored to advanced and application-specific requirements.
    ]]></description>
    <pubDate>Fri, 25 Sep 2026 11:33:05 +0000</pubDate>
</item>
<item>
    <title>Advanced RF power amplifier characterization: waveform engineering and time-domain load pull</title>
    <link>https://www.rohde-schwarz.com/in/applications/advanced-rf-power-amplifier-characterization-waveform-engineering-and-time-domain-load-pull_56279-1687232.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/advanced-rf-power-amplifier-characterization-waveform-engineering-and-time-domain-load-pull_56279-1687232.html</guid>
    <description><![CDATA[
    The combination of phase-calibrated wave measurements with load-pull capability is a highly practical workflow for advanced RF power amplifier characterization, waveform engineering and nonlinear model validation.
    ]]></description>
    <pubDate>Tue, 22 Sep 2026 13:15:12 +0000</pubDate>
</item>
<item>
    <title>Next generation light electromagnetic warfare (EW): Portable, compact, mission-ready</title>
    <link>https://www.rohde-schwarz.com/in/applications/next-generation-light-electromagnetic-warfare-ew-portable-compact-mission-ready_56279-1679808.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/next-generation-light-electromagnetic-warfare-ew-portable-compact-mission-ready_56279-1679808.html</guid>
    <description><![CDATA[
    The R&amp;S®PR300 portable monitoring receiver sets new benchmarks with its high performance, compact design and 125 MHz real-time bandwidth for tactical spectrum awareness. By combining high speed scanning with a user friendly interface, it enhances field operations and signal detection.
    ]]></description>
    <pubDate>Fri, 11 Sep 2026 08:19:46 +0000</pubDate>
</item>
<item>
    <title>R&amp;S®NESTOR – GNSS interference detection</title>
    <link>https://www.rohde-schwarz.com/in/applications/rs-nestor-gnss-interference-detection_56279-1666560.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/rs-nestor-gnss-interference-detection_56279-1666560.html</guid>
    <description><![CDATA[
    The jamming and spoofing of global navigation satellite systems (GNSS) is a growing threat that can significantly degrade GNSS receiver performance and jeopardize systems that rely on accurate positioning, navigation and timing (PNT) data. The threats can impact critical operations in transportation, public safety, critical infrastructure and autonomous systems. GNSS interference detection (GID) with R&amp;S®NESTOR cellular network analysis software detects GNSS jamming and spoofing in real time and provides alerts and insights. Identifying interference as it occurs helps quickly assess the situation, mitigate risks and maintain operational continuity in challenging RF environments.
    ]]></description>
    <pubDate>Tue, 25 Aug 2026 12:36:51 +0000</pubDate>
</item>
<item>
    <title>Accurate double pulse testing with the R&amp;S®RT-ZISO isolated probing system</title>
    <link>https://www.rohde-schwarz.com/in/applications/accurate-double-pulse-testing-with-the-rs-rt-ziso-isolated-probing-system_56279-1666496.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/accurate-double-pulse-testing-with-the-rs-rt-ziso-isolated-probing-system_56279-1666496.html</guid>
    <description><![CDATA[
    The double pulse testing (DPT) is crucial to evaluating the switching behavior for metal oxide semiconductor field effect transistors (MOSFET), insulated gate bipolar transistors (IGBT) and wide bandgap (WBG) power semiconductor devices. The slew rate of switching devices is increasing, especially on high-side power transistor where referencing switch nodes creates a fast common-mode environment. Conventional highvoltage differential probes have difficulties obtaining a good measurement with their limited common-mode rejection ratio at higher frequencies.
    ]]></description>
    <pubDate>Tue, 25 Aug 2026 12:00:56 +0000</pubDate>
</item>
<item>
    <title>R&amp;S®FSWP supports external local oscillators</title>
    <link>https://www.rohde-schwarz.com/in/applications/rs-fswp-supports-external-local-oscillators_56279-1654542.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/rs-fswp-supports-external-local-oscillators_56279-1654542.html</guid>
    <description><![CDATA[
    Increase sensitivity with external sources
    ]]></description>
    <pubDate>Wed, 5 Aug 2026 08:18:39 +0000</pubDate>
</item>
<item>
    <title>Automating GNSS Testing Using Python</title>
    <link>https://www.rohde-schwarz.com/in/applications/automating-gnss-testing-using-python_56280-1651521.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/automating-gnss-testing-using-python_56280-1651521.html</guid>
    <description><![CDATA[
    Within this application note the use of Python programming language to automatize GNSS tests using R&amp;S signal generators is shown. With the R&amp;S PyCharm1 plugin there exists an easy-to-use helper application which highly simplifies the first steps to start script based GNSS testing.Several GNSS use cases of R&amp;S vector signal generators require much repetitive set-up and configuration steps, where human errors may occur. To mitigate these errors Python scripts communicating over SCPI interface may be used to automate the procedures. On the other hand looking up the SCPI-commands one-by-one can be difficult and time-consuming. For an improved user experience JetBrains PyCharm, the RsInstrument Python Module and the R&amp;S Instrument Control PyCharm Plugin may be used to highly simplify the script writing process.This Application Note shows how to install the necessary software, connect to an R&amp;S generator and use the Instrument Control PyCharm Plugin to easily generate user defined Python scripts.
    ]]></description>
    <pubDate>Fri, 31 Jul 2026 12:02:12 +0000</pubDate>
</item>
<item>
    <title>How to synchronize R&amp;S MXO 4, 5, 5C Oscilloscopes for higher channel count</title>
    <link>https://www.rohde-schwarz.com/in/applications/how-to-synchronize-rs-mxo-4-5-5c-oscilloscopes-for-higher-channel-count_230850-1639197.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/how-to-synchronize-rs-mxo-4-5-5c-oscilloscopes-for-higher-channel-count_230850-1639197.html</guid>
    <description><![CDATA[
    This educational note describes the different methods for synchronizing two or more oscilloscopes and highlights their advantages and disadvantages. It includes a detailed user guide on how to use R&amp;S ScopeSync to synchronize two or more oscilloscopes.
    ]]></description>
    <pubDate>Wed, 15 Jul 2026 11:25:02 +0000</pubDate>
</item>
<item>
    <title>Understanding Noise in EMI Receivers</title>
    <link>https://www.rohde-schwarz.com/in/applications/understanding-noise-in-emi-receivers_56280-1637568.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/understanding-noise-in-emi-receivers_56280-1637568.html</guid>
    <description><![CDATA[
    This application note explains how noise sets the sensitivity and usable dynamic range of EMI receivers and how to configure measurements accordingly. It covers the essentials on noise figure and system design for noise reduction, such as the preamplifier placement. The application note explains receiver settings, that all shape the displayed noise floor, and the dynamic-range trade-offs between attenuation, preamplification and preselection. It helps understanding effects on the noise floor and their consequences for compliance EMI measurements and explains how to interpret datasheet values such as DANL. Reading it helps EMC engineers set up receivers for maximum sensitivity, avoid overestimating emissions near the limit, correctly compare instrument datasheet specifications, and distinguish emissions from instrument-generated noise floor artifacts such as spurious responses or input mismatching.
    ]]></description>
    <pubDate>Tue, 14 Jul 2026 08:08:38 +0000</pubDate>
</item>
<item>
    <title>EMC analysis of discontinuous disturbances (click rate)</title>
    <link>https://www.rohde-schwarz.com/in/applications/emc-analysis-of-discontinuous-disturbances-click-rate_56279-1636955.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/emc-analysis-of-discontinuous-disturbances-click-rate_56279-1636955.html</guid>
    <description><![CDATA[
    Most modern electronically controlled appliances still switch their loads – such as heating elements and motors – with mechanical relays. Each relay opening or closing generates a short, broadband click that can exceed the disturbance voltage limits of a quasi-peak (QP) detector. Because these transients are intermittent, they are evaluated separately as discontinuous disturbances (clicks) in line with CISPR 14-1/EN 55014-1.
    ]]></description>
    <pubDate>Mon, 13 Jul 2026 13:27:53 +0000</pubDate>
</item>
<item>
    <title>Bridging the gap: enhancing connectivity and coverage beyond offshore wind farms</title>
    <link>https://www.rohde-schwarz.com/in/applications/bridging-the-gap-enhancing-connectivity-and-coverage-beyond-offshore-wind-farms_56279-1636954.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/bridging-the-gap-enhancing-connectivity-and-coverage-beyond-offshore-wind-farms_56279-1636954.html</guid>
    <description><![CDATA[
    Empowering coastal surveillanceOffshore wind farms, located 10 to 20 nautical miles from shore, present significant communications challenges due to the high density of wind turbines. The turbines create interference and blind spots that hinder effective communications and surveillance at sea. Maintaining reliable communications by extending beyond line of sight (BLOS) coverage and overall communications range is paramount.By integrating VHF/UHF radios into wind turbines, operators can ensure reliable communications even in blind spots, enabling remote control from shore stations to sea and therefore improving operational efficiency.
    ]]></description>
    <pubDate>Mon, 13 Jul 2026 12:53:09 +0000</pubDate>
</item>
<item>
    <title>Hybrid eCall verification</title>
    <link>https://www.rohde-schwarz.com/in/applications/hybrid-ecall-verification_56279-1631882.html</link>
    <guid isPermaLink="false">https://www.rohde-schwarz.com/in/applications/hybrid-ecall-verification_56279-1631882.html</guid>
    <description><![CDATA[
    End-to-end hybrid eCall module conformance testing under controlled network conditions in line with EN18052:2025
    ]]></description>
    <pubDate>Mon, 6 Jul 2026 15:30:45 +0000</pubDate>
</item>
    </channel>
</rss>
