Arbitrary waveform generator oscilloscopes

Arbitrary waveform generator oscilloscopes
Ingrandisci immagine
Arbitrary waveform generator oscilloscopes
Ingrandisci immagine
Arbitrary waveform generator oscilloscopes
Ingrandisci immagine
Arbitrary waveform generator oscilloscopes, Screenshot Arbitrary waveform generator oscilloscopes, Application Image Arbitrary waveform generator oscilloscopes, Back view

Key Facts

  • Every R&S®RTP, R&S®RTO2000 and R&S®RTE can be enhanced to include an arbitrary waveform generator
  • Test your device with native signals
  • Single-ended and differential interface stimulation
  • Fully automated compliance tests with the R&S®B6 option
  • Multi-domain icon

Brief description

Arbitrary waveform and pattern generator with 14-bit resolution, 2 analog channels, 8 digital channels, 100 MHz bandwidth, 40 Msample/channel memory, 500 Msample/s sampling rate. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Before playing signals back, the user can preview them to quickly check signal correctness.

Features & benefits

Enhancement for R&S®RTP, R&S®RTO2000 and R&S®RTE oscilloscopes

The R&S®RTP, R&S®RTO2000 and R&S®RTE oscilloscopes can be enhanced with a fully integrated arbitrary waveform and pattern generator. The generator provides 2 analog and 8 digital channels with up to 100 MHz bandwidth, 500 Msample/s and 14-bit resolution and can be operated as a pattern, function or modulation generator. It is suitable for education, design and R&D purposes.

Ingrandisci immagine

Single-ended and differential interface stimulation

For testing differential devices, the generators can be coupled and offset from each other. With the offset capability of amplitude and phase in coupled mode, you can simulate both ideal and non-ideal conditions. Differential devices, such as differential amplifiers or I/Q mixers, can be tested against amplitude impairments and phase imbalances.

Ingrandisci immagine

Test your device with native signals

Testing your device with real-world signals opens up a new method to test the margins of your design. The arbitrary waveform generator lets you play back waveforms that are captured on the oscilloscope. The captured waveforms can be manipulated by changing the amplitude and offset level or be superimposed with noise to evaluate a device against design criteria.

Ingrandisci immagine

Fully automated compliance tests

Compliance tests can be fully automated utilizing the B6 arbitrary waveform generator, eliminating the need for an external signal source. R&S®ScopeSuite is able to control the waveform generator and provide, for instance, the disturbing signal needed for Ethernet compliance testing. As a result, the R&S®RTO and R&S®RTP offer the most compact compliance test solutions on the market.

Ingrandisci immagine

Available models

Available models
Modelli
Analog channels
Digital channels
Bandwidth
Sample rate
Resolutions
Base unit

R&S®RTE-B6

Order Number 1326.3012.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 Msample/s
Resolutions
14 bit
Base unit

R&S®RTO-B6

Order Number 1329.7054.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 Msample/s
Resolutions
14 bit
Base unit

R&S®RTP-B6

Order Number 1333.2418.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 Msample/s
Resolutions
14 bit
Base unit

R&S®RTO6-B6

Order Number 1801.6758.02

Analog channels
2
Digital channels
8
Bandwidth
100 MHz
Sample rate
500 MSample/s
Resolutions
14 bit
Base unit

R&S®MXO4-B6

Order Number 1335.4147.02

Analog channels
2
Digital channels
-
Bandwidth
100 MHz
Sample rate
500 MSample/s
Resolutions
18 bit
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.