Key Facts

  • Frequency range 9 kHz to 30 MHz
  • Power handling capacity up to 16 A (country-specific)
  • Simulated impedance (50 μH + 5 Ω) || 50 Ω in line with CISPR 16-1-2
  • V-network in line with CISPR, EN, VDE, ANSI, FCC Part 15 and MIL-STD-461
  • Calibrated in line with CISPR 16-1-2
  • 3-year warranty extension

For disturbance voltage measurements on single-phase EUTs

The R&S ENV216 two-line V-network meets the requirements of CISPR 16-1-2 and EN 55016-1-2 for V-networks with a simulated impedance of (50 μH + 5 Ω) || 50 Ω in the frequency range from 9 kHz to 30 MHz as well as the ANSI C63.4 in the frequency range from 150 kHz to 30 MHz. A socket with protective earth contacts connects to the EUT. Various models with country-specific connector systems are available. The compact design and low weight make the R&S®ENV216 ideal for frequently varying applications, especially for on-site disturbance voltage measurements on single-phase EUT.

Features & benefits

Air-core inductance and artificial hand

Air-core design and artificial hand

The R&S®ENV216 two-line V-network is based on air-core inductances and contains a artificial hand  to mimic the influence of the user’s hand while measuring  disturbance voltage.

Highpass filter

Switch-selectable 150 kHz highpass filter 

 A 150 kHz highpass filter can be inserted to prevent the measuring receiver from being overloaded by high levels of low frequency spectra.

Attenuator

Built-in 10 dB attenuator pad

The R&S®ENV216 two-line V-network is equipped with a 10 dB attenuator pad to ensure standard impedance irrespective of the measuring receiver's input attenuation. 

Pulse limiter

Built-in pulse limiter (can be switched off)

A built-in pulse limiter that can be switched off protects the measuring receiver's input from high energy radio frequency interference pulses.

Remote control

Remote control with TTL levels (compatible with Rohde & Schwarz measuring receivers)

TTL control inputs that can be driven by controllers or Rohde & Schwarz measuring receivers are provided for remote control of phase selection and highpass filter activation in an automatic test system. Optocouplers prevent pick-up of external disturbances.

Available models

Available models
Modelli
Max. continuous current
Country-specific connector

R&S®ENV216

Order Number 3560.6550.12

Max. continuous current
16 A
Country-specific connector
Germany, Austria, Finland, the Netherlands, Norway, Russia, Sweden, Korea; occasionally: Portugal, Spain

R&S®ENV216

Order Number 3560.6550.13

Max. continuous current
13 A
Country-specific connector
UK, Ireland, Hong Kong, Malaysia, Singapore

R&S®ENV216

Order Number 3560.6550.14

Max. continuous current
16 A
Country-specific connector
France, Belgium and Czech Republic

R&S®ENV216

Order Number 3560.6550.15

Max. continuous current
10 A
Country-specific connector
China, Australia, New Zealand

R&S®ENV216

Order Number 3560.6550.16

Max. continuous current
15 A
Country-specific connector
USA, Canada, Japan, Taiwan, Mexico, Central America

Available options

General
Product
Descrizione
R&S®EZ-21

Order Number 1107.2087.03

Descrizione

Control Cable, 3 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200

R&S®EZ-21

Order Number 1107.2087.10

Descrizione

Control Cable, 10 m

from R&S®ESU/ESCI/ESPI/ESIB/ESxS/EPL1000 and FPL1000 to R&S®AMN6500/ENV216/ENV432/ENV4200 

R&S®EZ-29

Order Number 1326.6470.03

Descrizione

Control Cable, 3 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

R&S®EZ-29

Order Number 1326.6470.10

Descrizione

Control Cable, 10 m

ESW, ESR, ESRP, ESL, FSW/FSVx to ENVxxx

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.