R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front low R&S®NGP800 power supply series, 3D R&S®NGP800 power supply series, back view R&S®NGP800 power supply series, 3D R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front view R&S®NGP800 power supply series, front view

Key Facts

  • Max. output power: 800 W
  • Max. voltage per channel: 32 V or 64 V
  • Max. current per channel: 10 A or 20 A
  • Up to 250 V or 80 A in series or parallel operation
  • Intuitive, price-transparent online product configurator

A partire da 3.360 EUR

Boost your efficiency with quadcore power

The R&S®NGP800 DC power supply series, comprising of five models with 400 W or 800 W, provides maximum power at a variety of operating points. The two or four 200 W outputs can each supply up to 64 V or up to 20 A. Electrically equivalent and galvanically isolated outputs can be wired in series or parallel for up to 250 V or 80 A. The R&S®NGP800 DC power supply series is ideal for a variety of T&M scenarios: automotive, R&D, manufacturing and general purpose use. 
Configure your R&S®NGP800 with our online configurator tool for: 
- full price transparency
- ease of configuration
- fast processing of your request and purchase from authorized distributor of your choice
Click "configure and quote" and start your configuration now.
 

Features & benefits

Touch display

High-resolution touch display for easy operation

The large high-resolution touch display makes operation easy. Quickly navigate through the menus to access all functions and settings. Enter values much faster with the virtual keyboard instead of a knob. The home screen gives you a clear overview of all your channels. Each channel can be selected for a more detailed view with a wide variety of additional information, such as statistics and icons indicating the status of set protection or special functions.

The home screen gives a clear overview of all channels
Ingrandisci immagine

The home screen gives a clear overview of all channels

FlexPower

Get the maximum power at various operating points

Unlike with single range power supplies, you can generate variable voltage and current combinations within the overall power limit of 200 W per channel. This technology makes your power supply a lot more versatile, covering a wider range of applications.

V/I-curves for 32 V output and 64 V output
Ingrandisci immagine

V/I-curves for 32 V output and 64 V output

Parallel & serial operation

Up to 250 V or 80 A

If your application requires more voltage or current, connect the outputs in series or parallel and get up to 250 V (R&S®NGP824) or 80 A ( R&S®NGP804) - for the flexibility you always wanted. Using the tracking function, voltage and current are adjusted on all selected channels simultaneously.

Parallel & serial operation
Ingrandisci immagine

Parallel & serial operation

Built-in measurements

Integrated statistics

The built-in measurements reduce the need for an external multimeter and simplify the setup. The separate voltage and current meters on each output have a resolution of 1 mV and 0.5 mA over the full output range of 64 V and 20 A. Integrated statistics show the min, avg and max values for power, voltage and current as well as the energy count.

One-channel-view with details and integrated statistics
Ingrandisci immagine

One-channel-view with details and integrated statistics

Data Logging

Key to long-term monitoring

Logging data is key to long-term monitoring, reviewing test setups and repeating test conditions when analyzing power behavior or optimizing power consumption. The R&S®NGP800 power supplies simultaneously log voltage and current measurements over time on all outputs. You can easily export the timestamped data as a .CSV file for reports and documentation.

Logging setup dialog
Ingrandisci immagine

Logging setup dialog

Arbitrary function

QuickArb

Emulate the normal behavior of your power subsystem early in the design process and simulate power problems for DUT design verification. The QuickArb function lets you generate voltages that vary over time and current sequences of output changes with dwell times down to 1 ms. Load up to eight subgroup files into one sequence to create complex patterns.

Fast programming of sequences with the Arb Editor
Ingrandisci immagine

Fast programming of sequences with the Arb Editor

Graphical View

Display of measured data

The Graphical View function allows fast and convenient analysis, especially of changing processes, such as charging and discharging or switching between different operating states of a DUT. Integrating all measurements in one box not only reduces the complexity of the test setup, but also ensures the integrity and correlation of all measurements by design.

The Graphical View function interface on an R&S®NGP800 power supply
Ingrandisci immagine

The Graphical View function interface on an R&S®NGP800 power supply

Remote control via VNC client

Control your instrument from anywhere

Via VNC connection the R&S®NGP800 power supplies can be controlled and operated from any location. All functions that can be reached by manual operation can also be accessed via remote control by VNC. The connection between power supply and PC can be established via LAN in the same network.

Remote control of R&S®NGP800 power supply via VNC
Ingrandisci immagine

Remote control of R&S®NGP800 power supply via VNC

Easy to use, price transparent configurator

We strive to give customers the right T&M instrument quickly, easily, and with full price transparency. The R&S®NGP800 and other instruments from the R&S Essentials portfolio can now be configured online, providing you with the following benefits:
- User-friendly and easy to navigate configurator
- Full cost transparency at every step of configuration
- Fast order processing through authorized distribution partners 
- Next-day delivery from selected partners

Ingrandisci immagine

Available models

Available models
Modelli
Number of output channels
Max. output power
Output voltage per channel
Output current per channel
Orario d'inizio

R&S®NGP802

Order Number 5601.4007.05

Number of output channels
2
Max. output power
400 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 20 A
Orario d'inizio
3.360 EUR

R&S®NGP804

Order Number 5601.4007.02

Number of output channels
4
Max. output power
800 W
Output voltage per channel
0 V to 32 V
Output current per channel
0 A to 20 A
Orario d'inizio
5.000 EUR

R&S®NGP814

Order Number 5601.4007.04

Number of output channels
4
Max. output power
800 W
Output voltage per channel
Ch 1, Ch 2: 0 V to 32 V
Ch 3, Ch 4: 0 V to 64 V
Output current per channel
Ch 1, Ch 2: 0 A to 20 A
Ch 3, Ch 4: 0 A to 10 A
Orario d'inizio
5.000 EUR

R&S®NGP822

Order Number 5601.4007.06

Number of output channels
2
Max. output power
400 W
Output voltage per channel
0 V to 64 V
Output current per channel
0 A to 10 A
Orario d'inizio
3.360 EUR

R&S®NGP824

Order Number 5601.4007.03

Number of output channels
4
Max. output power
800 W
Output voltage per channel
0 V to 64 V
Output current per channel
0 A to 10 A
Orario d'inizio
5.000 EUR
Specifications
Electrical specifications
Number of output channels 2 or 4
Total output power max. 400 W/800 W
Maximum output power per channel 200 W
Output voltage per channel 0 V to 32 V (32 V channels)
0 V to 64 V (64 V channels)
Maximum output current per channel 20 A (32 V channels)
10 A (64 V channels)
Voltage ripple and noise (20 Hz to 20 MHz) < 3 mV (RMS)
< 30 mV (Vpp) (meas.)
Current ripple and noise (20 Hz to 20 MHz) < 3.5 mA (RMS) (meas.)
Load recovery time (10 % to 90 % load change within a band of ± 20 mV of set voltage) < 400 μs (meas.)
Programming resolution voltage 1 mV
Programming resolution current 0.5 mA
Output measurements
Readback resolution voltage 1 mV
Readback resolution current 0.5 mA
Readback accuracy voltage ±(% of output + offset) < 0.05 % + 5 mV (32 V channels)
< 0.05 % + 10 mV (64 V channels)
Readback accuracy current ±(% of output + offset) < 0.1 % + 20 mA (32 V channels)
< 0.1 % + 10 mA (64 V channels)
Special functions
Measurement functions voltage, current, power, energy
Protection functions OVP, OCP, OPP, OTP
FuseLink function
Fuse delay at output-on
Sense function
Sink mode
Output sequencing
Trigger input/output
Arbitrary function ● (QuickArb)
Analog/modulation interface
Data logging ● (standard mode)
Display and interfaces
Display TFT 5" 800 pixel × 480 pixel WVGA touch
Rear panel connections 8-pin connector block per 2 channels
Remote control interfaces: standard USB, LAN
Remote control interfaces: optional IEEE-488 (GPIB)
General data
Dimensions (W × H × D) 362 mm × 100 mm × 451 mm
Weight 7.5 kg/8.0 kg
Rack installation R&S®ZZA-GE23 option

Available options

General
Product
Descrizione
R&S®NG-B105

Order Number 5601.6000.02

Descrizione

IEEE-488 (GPIB) interface

General analysis
Product
Descrizione
R&S®NGP-K103

Order Number 5601.6300.03

Descrizione

Digital trigger I/O

R&S®NGP-K107

Order Number 5601.6200.03

Descrizione

Analog input

General accessories
Product
Descrizione
R&S®ZZA-GE23

Order Number 5601.4059.02

Descrizione

19" rack adapter, 2 HU

Related videos

Webpage, VNC & FTP on R&S®DC Power Supplies

Learn how easy it is to control and operate our instrument from any location via ethernet-based remote services

Aumenta la tua efficienza con la potenza degli alimentatori quadcore

Con quattro uscite indipendenti, ognuna delle quali fornisce fino a 64 V o 20 A, i nuovi alimentatori NGP800 aumenteranno l'efficienza di qualsiasi laboratorio.

feb 13, 2020

DC Supplies promotion

DC Supplies and Component analysis promotion

Maximize your bench performance and benefit from more than 19% of of fully equipped DC power supplies.

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.