PCIe 1.1/2.0/3.0 oscilloscope software

Triggering and decoding

PCIe 1.1/2.0/3.0 oscilloscope software
Ingrandisci immagine
PCIe 1.1/2.0/3.0 T&D App Icon

Key Facts

  • Full support of PCI Express 1.1/2.0/3.0 up to 8 Gbit/s and up to 4 times the link size
  • Reliable and consistent decoding with configurable CDR or built-in receiver equalization settings
  • Triggering on protocol details such as transaction layer packets (TLP), data link layer packets (DLLP), ordered sets (OS) and errors
  • Selectable decoding layer: bits, scrambled or descrambled, 8b10b, or final
  • Powerful search and measurement capabilities
  • Multi-domain icon

Oscilloscope software

The R&S®RTO2000,; R&S®RTO6 and R&S®RTP; oscilloscopes support triggering and decoding of PCI Express Gen 1.1 and 2.0 signals. In addition, the R&S®RTP supports Gen 3.0 signals. Users can set up decoding in seconds via the intuitive menu dialogs. For detailed analysis, results can be viewed as color-coded telegrams and/or in a table. Errors and other protocol-specific fields, such as TLP and OS are identified efficiently using the oscilloscopes' protocol trigger. 

Features & benefits

Fast bus setup

From the app cockpit, any protocol can be configured in only a few steps. Once the desired generation/bus speed has been chosen, the relevant channels selected and the correct levels set, decoding begins automatically.

For PCI Express, a link size of up to 4 can be decoded simultaneously. 

Ingrandisci immagine

Simple and quick configuration of the PCIe bus decoding 

Display as color-coded bus

Efficiently analyze the decoded bus frames by overlaying the time domain signal with PCIe color-coded packets. Messages can be displayed in hex, bin and ASCII format. Users have the choice to display the data in a concise table or with all detailed information. The flexible screen setup ensures you always have an excellent overview. 

Ingrandisci immagine

Decoded PCIe Gen 3 (x4 link) shown with the synchronized waveform, zoom window and with all details in the result table

Strong trigger capability

Trigger on specific PCIe packets, data and errors

The protocol-specific trigger lets you reliably isolate protocol events and errors. High acquisition rates make Rohde & Schwarz oscilloscopes ideal for finding errors quickly. Protocol-specific trigger results can then be decoded. For PCIe, this allows users to trigger on specific OS (SKP OS, Training Seq, etc.), DLLP (ACK, Vendor, etc.), TLP (Mem, IO, etc.) and errors (CRC16, LCRC, etc.).

Ingrandisci immagine

Select from a comprehensive list of protocol types for triggering to focus the acquisition on the details of interest

Powerful search and navigation capabilities

Comprehensive search functions simplify the analysis of long signal sequences. You can search for waveforms based on various criteria, such as signal faults and protocol content. All detected events are shown in a table with timestamps. The individual events can be examined in a zoom window with simple navigation between events.

Ingrandisci immagine

Search for protocol details in long acquisitions

Reliable decoding

The protocol dialog gives users additional settings to help ensure stable and reliable decoding. For example with PCIe Gen 1.1/2.0, the CDR/PLL settings can be fine-tuned to the captured signal. For Gen 3, RX equalization settings such as CTLE and DFE are built-in. 

Ingrandisci immagine

Advanced settings for PCIe decoding

Available models

Available models
Modelli
Serial standard
Decode table
Trigger
Search
Base unit

R&S®RTP-K72

Order Number 1337.8827.02

Serial standard
PCI Express 1.1./2.0
Decode table
Trigger
Search
Base unit

R&S®RTO-K72

Order Number 1326.3741.02

Serial standard
PCI Express 1.1./2.0
Decode table
Trigger
Search
Base unit

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.