R&S®TMU9 UHF Transmitter Family for TV

Maximum flexibility, minimum TCO

Key facts

  • Efficiency of up to 42 %
  • Unique flexibility
  • Small footprint

Brief description

The R&S®TMU9 UHF transmitter family offers unique flexibility by providing more than 50 different standard configurations. Featuring efficiency of up to 42 %, it achieves the highest energy saving on the market.

Specifications

Digital TV
Standards DVB-T, DVB-T2, DVB-H, ISDB-T, ISDB-TB, ATSC, ATSC Mobile DTV, DTMB

Key facts

  • Efficiency of up to 42 %
  • Unique flexibility
  • Small footprint
  • Quick startup, easy operation and high availability

The R&S®TMU9 contains open source software packages. Copies of the respective licenses are included in the Open Source Acknowledgement, see Downloads/Software area of this web page.

Brief description

The R&S®TMU9 UHF transmitter family offers unique flexibility by providing more than 50 different standard configurations. Featuring efficiency of up to 42 %, it achieves the highest energy saving on the market. Plus, the simple system configuration allows quick startup. The high availability of the R&S®TMU9 ensures unsurpassed reliable operation. And its compact size saves space at the transmitter site.

The R&S®TMU9 air-cooled transmitters attain output powers in from 300 W to 3.0 kW for digital standards and up to 4.75 kW for analog standards. The transmitters are accommodated in only on rack, saving a lot of space at the transmitter site.

With efficiency values of up to 30 % in normal mode, the transmitters save a great deal of energy and significantly reduce CO2 emissions. The Doherty architecture for boosting efficiency increases this figure to up to 42 %. These figures are unparalleled on the market, making the R&S®TMU9 transmitter familie the global benchmark for broadcast transmitters with optimized operating costs.

The transmitters feature unique system variability. Innovative configurations, such as MultiTX or N+1 systems in a single rack, and built-in bandpass filters ensure short delivery times even for special transmitter configurations. Excellent efficiency and the integration of multiple transmitters into a single rack reduce the total cost of ownership (TCO) of a transmitter system by more than half over the system’s lifetime.

Specifications

Digital TV    
Standards   DVB-T, DVB-T2, DVB-H, ISDB-T,
ISDB-TB, ATSC, ATSC Mobile DTV, DTMB
Channel bandwidth DVB-T, DVB-H 5/6/7/8 MHz
  DVB‑T2 1.7/5/6/7/8 MHz
  ATSC 6 MHz
  ISDB‑T/ISDB-TB 6/8 MHz
  DTMB 8 MHz
Inputs DVB-T, DVB-H, DVB-T2, DTMB 2 × ASI (HP/LP), 75 Ω BNC, 2 × RJ-45
  ATSC 2 × SMPTE310M or 2 × ASI, 75 Ω BNC, 2 × RJ-45
  ISDB‑T/ISDB‑TB 2 × BTS, 75 Ω BNC/high impedance, 2 × RJ-45
Digital radio/Mobil TV in the VHF band standards DAB, DAB+, T-DMB
Channel bandwidth   1.536 Mhz
Inputs   2 x ETI, BNC 75 Ω/high impedance, 2 x EDI, RJ-45
Analog TV standards B/G, D/K, M2), N2), I, I1
Color transmission   PAL, NTSC, SECAM
Sound transmission   IRT dual-sound coding, FM single sound and NICAM728 (−13 dB/−20 dB) (optional), FM single sound (−10 dB)
Inputs   1 × video (75 Ω BNC, 2 × audio (XLR)
General data    
Frequency range UHF bands IV/V 470 MHz to 862 MHz
  VHF band III 170 MHz to 254 MHz
Supply voltage   230 V; 2 wires + PE (L1/N/PE) ± 15 %
    400/230 V; 4 wires + PE (L1/L2/L3/N/PE); ± 15 %
    240 V; 2 wires + PE (L1/L2/PE) ± 10 %
    208 V; 4 wires + PE (L1/L2/L3/N/PE) ± 10 %
Max. installation height   2000 m above sea level (> 2000m on request)
Operating temperature range   +1 °C to +45 °C
Relative humidity (max.)   95 %, noncondensing
Immunity 1)    
  to fast transients and bursts in line with
EC 61000-4-4
< 2 kV (AC supply),
< 1 kV (signal inputs)
  to surges in line with
EC 61000-4-5
symmetrical < 1 kV (e.g. L1-L2),
asymmetrical < 2 kV (e.g. L1-N)
Synchronization    
Reference frequency   10 MHz, 0.1 V to 5 V (Vpp) or TTL, BNC
Reference pulse   1 Hz, TTL, BNC
Operation    
Display unit with touchscreen and LEDs optional local operation and display
Ethernet interface, RJ-45   local, remote, standard web browser
  optional network management interface via SNMP
Parallel remote interface optional floating contacts for messages and commands

1) With built-in AC supply overvoltage protection; more stringent requirements must be satisfied by implementing appropriate measures in the station.
2) Single sound.

To comply with the applicable standards and limit values for the suppression of out-of-band emissions (and in the case of digital standards, also for maintaining the required shoulder distance), the transmitter may only be operated with suitable filters at the RF output.

Grazie.

La tua richiesta è stata inviata correttamente!

Il tuo team dell'assistenza Rohde & Schwarz

Richiedere un preventivo

Inserire il proprio quesito.
Inserire il proprio nome.
Inserire il proprio nome.
Si prega di inserire un indirizzo e-mail valido.
Si prega di inserire il nome dell'azienda.
Inserire il nome della propria città.
Inserire il codice postale.
Inserire il proprio numero di telefono.

Inserire il proprio Paese.
Autorizzazione al marketing

Desidero ricevere informazioni da Rohde & Schwarz tramite


Cosa significa nello specifico?

Accetto che ROHDE & SCHWARZ GmbH & Co. KG e l’entità ROHDE & SCHWARZ o l’azienda controllata riportata nelle note legali di questo sito web, potrà contattarmi tramite il canale prescelto (e-mail o posta) per scopi di marketing e pubblicità (ad es., informazioni su offerte speciali e sconti) in relazione a, in via non limitativa, prodotti e soluzioni del settore di collaudo e misurazione, comunicazioni sicure, monitoraggio e collaudo di rete, trasmissione, media e sicurezza informatica.

I tuoi diritti

La presente dichiarazione di consenso può essere revocata in qualsiasi momento inviando una e-mail con oggetto “Annulla iscrizione" all’indirizzo news@rohde-schwarz.com. In più, in ciascuna e-mail pubblicitaria inviata sarà allegato un link per annullare l’iscrizione. Nella ”Dichiarazione di riservatezza” vengono definiti ulteriori dettagli sull’utilizzo dei dati personali e sulla procedura di ritiro.

Ti preghiamo di inserire i caratteri presenti nell'immagine
show captcha
I dati inseriti non sono corretti.
Do not enter data in this field
Grazie.

La tua richiesta è stata inviata correttamente!

Il tuo team dell'assistenza Rohde & Schwarz

Richiedi informazioni

Inserire il proprio quesito.
Inserire il proprio nome.
Inserire il proprio nome.
Si prega di inserire un indirizzo e-mail valido.
Si prega di inserire il nome dell'azienda.
Inserire il nome della propria città.
Inserire il codice postale.

Inserire il proprio Paese.
Autorizzazione al marketing

Desidero ricevere informazioni da Rohde & Schwarz tramite


Cosa significa nello specifico?

Accetto che ROHDE & SCHWARZ GmbH & Co. KG e l’entità ROHDE & SCHWARZ o l’azienda controllata riportata nelle note legali di questo sito web, potrà contattarmi tramite il canale prescelto (e-mail o posta) per scopi di marketing e pubblicità (ad es., informazioni su offerte speciali e sconti) in relazione a, in via non limitativa, prodotti e soluzioni del settore di collaudo e misurazione, comunicazioni sicure, monitoraggio e collaudo di rete, trasmissione, media e sicurezza informatica.

I tuoi diritti

La presente dichiarazione di consenso può essere revocata in qualsiasi momento inviando una e-mail con oggetto “Annulla iscrizione" all’indirizzo news@rohde-schwarz.com. In più, in ciascuna e-mail pubblicitaria inviata sarà allegato un link per annullare l’iscrizione. Nella ”Dichiarazione di riservatezza” vengono definiti ulteriori dettagli sull’utilizzo dei dati personali e sulla procedura di ritiro.

Ti preghiamo di inserire i caratteri presenti nell'immagine
show captcha
I dati inseriti non sono corretti.
Do not enter data in this field
International Website