R&S®ZVAX-TRM extension unit

Configurable signal conditioning for measurements on active components

R&S®ZVAX-TRM extension unit
Ingrandisci immagine
R&S®ZVAX-TRM extension unit
Ingrandisci immagine
R&S®ZVAX-TRM extension unit
Ingrandisci immagine
R&S®ZVAX-TRM extension unit
Ingrandisci immagine
R&S®ZVAX-TRM extension unit
Ingrandisci immagine
R&S®ZVAX-TRM extension unit, Front view R&S®ZVAX-TRM extension unit, Front view R&S®ZVAX-TRM extension unit, Side view R&S®ZVAX-TRM extension unit, Back view R&S®ZVAX-TRM extension unit, Side view

Key Facts

  • Extension unit for the R&S®ZVA/ZVT network analyzer
  • For measurements of T/R modules, receivers, transceivers, power amplifiers
  • Base unit ready for high power measurements
  • R&S®ZVAX-TRM models up to 24/40/50/67 GHz
  • Flexible configuration for the required application
  • 3-year warranty extension

Extension unit for measurements on active components

Configurable signal conditioning for R&S®ZVA/ZVT

The configurable R&S®ZVAX‑TRM extension unit is used with an R&S®ZVA/R&S®ZVT network analyzer to provide signal conditioning for demanding measurements on active devices under test. For example, it allows measurements on pulsed signals or noise figure measurements on transmit/receive (T/R) modules. Together with an R&S®ZVA network analyzer, the R&S®ZVAX‑TRM provides customized test sets for applications up to 24/40/50/67 GHz (restrictions on some options for the 67 GHz model).

Features & benefits

Configurable test system

Flexible characterization of T/R modules

The R&S®ZVAX‑TRM is an extension unit for the R&S®ZVA/ZVT. The configurable external box adds hardware components required for transmit/receive modules or high-power testing. The base unit has two ports, couplers, and path access loops. Modules can be added as needed: output pre-amplifiers, combiners, pulse modulators, receiver pre-amplifiers. Uncoupling the options from the VNA protects it and maintains  full RF performance for the base unit when measuring without the R&S®ZVAX-TRM.

Convenient control via a graphical user interface
Ingrandisci immagine

Convenient control via a graphical user interface

Excellent performance

Excellent performance data for measurements on T/R modules

The T/R module characteristics can be measured in both directions, making bidirectional pulse measurements possible. High output power levels are standard, even with a fully configured R&S®ZVAX-TRM.

Compact solution with open architecture

Signal access points to integrate external components and instruments

Measuring power or pulse profile calls for different test setups. To meet these requirements, the R&S®ZVAX-TRM offers the following:

  • Access to generator path (e.g. connect external power amplifiers)
  • Access to receiver path (e.g. connect attenuators for power measurements or to output signal to an external instrument)
  • Access to reverence signal (e.g. to utilize automatic level control)

Ingrandisci immagine

Customized configuration

Get what you need

The R&S®ZVAX-TRM extension unit in its base configuration supports high-power two-port measurements up to +43 dBm (pulsed signals) and can easily loop in external components.
For greater flexibility the R&S®ZVAX-TRM functions can be expanded with diverse options such as:

  • pulse modulators
  • low-noise preamplifiers
  • output amplifiers
  • combiners

Ingrandisci immagine

Available models

Available models
Modelli
Frequency range

R&S®ZVAX-TRM24

Order Number 1322.6500.24

Frequency range
24 GHz

R&S®ZVAX-TRM40

Order Number 1322.6500.40

Frequency range
40 GHz

R&S®ZVAX-TRM50

Order Number 1322.6500.50

Frequency range
50 GHz

R&S®ZVAX-TRM67

Order Number 1322.6500.67

Frequency range
67 GHz

Available options

R&S®ZVAX-TRM24 extension unit
Product
Descrizione
R&S®ZVAX24B31

Order Number 1322.7020.24

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 1

R&S®ZVAX24B32

Order Number 1322.7036.24

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM24

10 MHz to 24 GHz, measurement path port 2

R&S®ZVAX24B712

Order Number 1322.6969.24

Descrizione

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B73

Order Number 1322.6975.24

Descrizione

Pulse modulators for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX24B112

Order Number 1322.6981.24

Descrizione

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX24B134

Order Number 1322.6998.24

Descrizione

Output amplifiers for R&S®ZVAX-TRM24

10 MHz to 24 GHz, for increased output power at network analyzer port 3 and port 4 or at R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX24B213

Order Number 1322.7007.24

Descrizione

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX24B224

Order Number 1322.7013.24

Descrizione

Combiner for R&S®ZVAX-TRM24

10 MHz to 24 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM40 extension unit
Product
Descrizione
R&S®ZVAX40B31

Order Number 1322.7020.40

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 1

R&S®ZVAX40B32

Order Number 1322.7036.40

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM40

10 MHz to 40 GHz, measurement path port 2

R&S®ZVAX40B712

Order Number 1322.6969.40

Descrizione

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B73

Order Number 1322.6975.40

Descrizione

Pulse modulators for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX40B112

Order Number 1322.6981.40

Descrizione

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX40B134

Order Number 1322.6998.40

Descrizione

Output amplifiers for R&S®ZVAX-TRM40

10 MHz to 40 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX40B213

Order Number 1322.7007.40

Descrizione

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX40B224

Order Number 1322.7013.40

Descrizione

Combiner for R&S®ZVAX-TRM40

10 MHz to 40 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM50 extension unit
Product
Descrizione
R&S®ZVAX50B31

Order Number 1322.7020.50

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 1

R&S®ZVAX50B32

Order Number 1322.7036.50

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM50

10 MHz to 50 GHz, measurement path port 2

R&S®ZVAX50B712

Order Number 1322.6969.50

Descrizione

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B73

Order Number 1322.6975.50

Descrizione

Pulse modulators for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate pulsed signals at network analyzer port 3 or at R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX50B112

Order Number 1322.6981.50

Descrizione

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX50B134

Order Number 1322.6998.50

Descrizione

Output amplifiers for R&S®ZVAX-TRM50

10 MHz to 50 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX50B213

Order Number 1322.7007.50

Descrizione

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX50B224

Order Number 1322.7013.50

Descrizione

Combiner for R&S®ZVAX-TRM50

10 MHz to 50 GHz, to generate two-tone signal at R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

R&S®ZVAX-TRM67 extension unit
Product
Descrizione
R&S®ZVAX67B31

Order Number 1322.7020.67

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 1

R&S®ZVAX67B32

Order Number 1322.7036.67

Descrizione

Low-noise pre-amplifier for R&S®ZVAX-TRM67

10 MHz to 67 GHz, measurement path port 2

R&S®ZVAX67B712

Order Number 1322.6969.67

Descrizione

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B73

Order Number 1322.6975.67

Descrizione

Pulse modulators for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate pulsed signals at network analyzer port 3 or at the R&S®ZVAX‑TRM24 port 1 (B213 option active)

R&S®ZVAX67B112

Order Number 1322.6981.67

Descrizione

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at the R&S®ZVAX‑TRM24 port 1 and port 2

R&S®ZVAX67B134

Order Number 1322.6998.67

Descrizione

Output amplifiers for R&S®ZVAX-TRM67

10 MHz to 67 GHz, for increased output power at network analyzer port 3 and port 4 or at the R&S®ZVAX‑TRM24 port 1 and port 2 (B213/B224 option active)

R&S®ZVAX67B213

Order Number 1322.7007.67

Descrizione

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 1 (SRC 1 + 3)

R&S®ZVAX67B224

Order Number 1322.7013.67

Descrizione

Combiner for R&S®ZVAX-TRM67

10 MHz to 67 GHz, to generate two-tone signal at the R&S®ZVAX‑TRM port 2 (SRC 2 + 4)

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.