Promo: What's next? Taking industry leadership or watching from the sidelines?

What's next? Taking industry leadership or watching from the sidelines?

Take the lead with up to 60% off our devices!

R&S®NRQ6 frequency selective power sensor

A milestone in power measurements

R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor
Ingrandisci immagine
R&S®NRQ6 frequency selective power sensor, Front High R&S®NRQ6 frequency selective power sensor, Side view R&S®NRQ6 frequency selective power sensor, Front view R&S®NRQ6 frequency selective power sensor, Side view R&S®NRQ6 frequency selective power sensor, Side view R&S®NRQ6 frequency selective power sensor, Side view R&S®NRQ6 frequency selective power sensor, Back view R&S®NRQ6 frequency selective power sensor, Side view

Key Facts

  • Frequency selective power measurements from 50 MHz to 6 GHz
  • Power measurement range: -130 dBm to +20 dBm
  • 100 MHz measurement bandwidth
  • I/Q data capturing for RF vector signal analysis
  • Phase coherent measurements for low-power modulated signals
  • Product of the year

The new category of T&M devices

The R&S®NRQ6 combines the accuracy of a power meter with excellent dynamic range

The R&S®NRQ6 is based on receiver technology and can perform band-limited power measurements down to -130  dBm. The R&S®NRQ6 combines high-precision with high-speed measurements beyond the limits of currently available power meters. In addition to conventional continuous average measurements, the R&S®NRQ6 has a trace display function and also performs ACLR measurements. The optional R&S®NRQ6-K1 I/Q data interface, R&S®NRQ6-K2 power servoing and R&S®NRQ6-K3 phase coherent measurements options complete the R&S®NRQ6 as new category of test and measurment devices.

Features & benefits

Diverse measurement functions

Precise and fast with receiver based architecture

  • Continuous average power measurements down to -130 dBm
  • I/Q data capturing for RF vector signal analysis
  • Phase coherent measurements
  • Trace measurements
  • ACLR measurements
  • Ultrafast triggered pulse measurements
  • RF power, EVM and phase measurements with one single instrument

R&S®NRQ6 trace measurement on a pulsed signal
Ingrandisci immagine

R&S®NRQ6 trace measurement on a pulsed signal

Easy operation

Maximum performance in minimum form factor

  • Intuitive web GUI
  • Diverse autoset functions
  • Automatic frequency tracking
  • Spectrum display for signal check
  • Hardware interfaces for user convenience

Signal check for a 20 MHz LTE signal
Ingrandisci immagine

Signal check for a 20 MHz LTE signal

I/Q data capturing

The R&S®NRQ6 as a standalone RF frontend

The R&S®NRQ6 can be used as a standalone RF frontend to capture vector-modulated I/Q signals. With the optional R&S®NRQ6-K1 I/Q data interface, captured I/Q data can be read out using SCPI commands. The data is demodulated and analyzed using external software, e.g. R&S®VSE. With the R&S®NRQ6 version 2.10 and the R&S®VSE version 1.70, direct data aquisition and control is possible.

5G NR measurement with R&S®NRQ6 and R&S®VSE
Ingrandisci immagine

5G NR measurement with R&S®NRQ6 and R&S®VSE

Fast power servoing with R&S®SGT100A

In component test applications non-linear characteristics of DUT´s make it difficult to set up a specific output power. The R&S®NRQ6-K2 power servoing option enables a dedicated serial communications channel over the trigger connectors between R&S®NRQ6 and R&S®SGT100A. The desired power will be set in several iterations and is finished typically in 1 ms to 1.5 ms.

Power servoing with R&S®NRQ6 and R&S®SGT100A
Ingrandisci immagine

Power servoing with R&S®NRQ6 and R&S®SGT100A

In the power servoing setup the R&S®NRQ6 can perform also power measurements without disconnecting, just by remote control commands.

Phase coherent measurements

Calibration of multiple active antenna modules for beamforming

The synchronous phase coherent measurements (option R&S®NRQ6-K3) are based on a primary/secondary relationship between two or more R&S NRQ6. The primary forwards the local oscillator signal (LO) and its clock signal (CLK) to the secondary(ies) and triggers the secondary(ies). The RF phases can be measured at up to 8 ports, where the typical uncertainty is only 0.1 degree at an power of -60 dBm.

R&S®NRQ6 multichannel phase difference measurement
Ingrandisci immagine

R&S®NRQ6 multichannel phase difference measurement

Results of a measurement with one R&S®NRQ6 as primary (only used for distribution of TRG, CLK and LO signals) and eight R&S®NRQ6 as secondaries.

High measurement speed

Beyond limits of conventional diode power sensors

Every diode based power meter works without band limitation in the specified frequency range. Precise measurement of low-power signals requires averaging of multiple measurement samples and this increases the measurement time. The diode based power meter technology is mature, and therefore only limited product innovations are possible. The receiver technology based R&S®NRQ6 has significantly increased the measurement speed for low-power signals.

Measurement time comparison for a CW signal
Ingrandisci immagine

Measurement time comparison for a CW signal

With the R&S®NRQ6 the measurement time is reduced e.g. by a factor of ca. 20.000 in comparison to the NRP8S for a -50 dBm CW signal.

Available models

Available models
Modelli
Frequency range
Level range
Dynamic range (sensor dependent)
LAN interface
Connector type

R&S®NRQ6

Order Number 1421.3509.02

Frequency range
50 MHz - 6 GHz
Level range
-130 dBm - +20 dBm
Dynamic range (sensor dependent)
up to 150 dBm (RBW dependent)
LAN interface
Connector type
N (m)
Specifications
Frequency range
50 MHz to 6.0 GHz
Impedance matching (SWR)
50 MHz to 100 MHz <1.20
>100 MHz to 2.0 GHz <1.13
>2.0 GHz to 6.0 GHz <1.20
Power measurement range
dynamic range dependent on RBW (10 Hz to 400 MHz) -130 dBm to +20 dBm
Damage level
max. average power 1 W (+30 dBm) continuous
max. peak envelope power 2 W (+33 dBm) for max. 1 µs
max. DC voltage ±20 V
RF input attenuation
0 dB, 30 dB
Measurement subranges
RF input attenuation = 0 dB -130 dBm to -10 dBm
RF input attenuation = 30 dB -100 dBm to +20 dBm
Resolution bandwidth (RBW)
single-sideband (SSB) mode 10 Hz to 40 MHz
zero IF mode (RF input frequency ≥ 400 MHz) 50 MHz, 80 MHz, 100 MHz, 400 MHz
Acquisition
sample rate 119 MHz to 121 MHz
Displayed average noise level (DANL)
RF input attenuation = 0 dB
50 MHz to 100 MHz < –148 dBm (1 Hz)
>100 MHz to 400 MHz <-153 dBm (1 Hz)
>400 MHz to 2.4 GHz <-156 dBm (1 Hz)
>2.4 GHz to 6.0 GHz <-153 dBm (1 Hz)
RF input attenuation = 30 dB
50 MHz to 100 MHz <-118 dBm (1 Hz)
>100 MHz to 400 MHz <-123 dBm (1 Hz)
>400 MHz to 2.4 GHz <-126 dBm (1 Hz)
>2.4 GHz to 6.0 GHz <-121 dBm (1 Hz)
Uncertainty for absolute power measurements
RF input attenuation = 0 dB
50 MHz to 100 MHz 0.156 dB (operating temperature range +20 °C to +25 °C)
0.167 dB (operating temperature range +15 °C to +35 °C)
0.211 dB (operating temperature range 0 °C to +50 °C)
>100 MHz to 400 MHz 0.130 dB (operating temperature range +20 °C to +25 °C)
0.143 dB (operating temperature range +15 °C to +35 °C)
0.192 dB (operating temperature range 0 °C to +50 °C)
>400 MHz to 3 GHz 0.080 dB (operating temperature range +20 °C to +25 °C)
0.100 dB (operating temperature range +15 °C to +35 °C)
0.163 dB (operating temperature range 0 °C to +50 °C)
>3 GHz to 6 GHz 0.092 dB (operating temperature range +20 °C to +25 °C)
0.110 dB (operating temperature range +15 °C to +35 °C)
0.169 dB (operating temperature range 0 °C to +50 °C)
RF input attenuation = 30 dB
50 MHz to 100 MHz 0.176 dB (operating temperature range +20 °C to +25 °C)
0.189 dB (operating temperature range +15 °C to +35 °C)
0.237 dB (operating temperature range 0 °C to +50 °C)
>100 MHz to 400 MHz 0.147 dB (operating temperature range +20 °C to +25 °C)
0.162 dB (operating temperature range +15 °C to +35 °C)
0.216 dB (operating temperature range 0 °C to +50 °C)
>400 MHz to 3 GHz 0.093 dB (operating temperature range +20 °C to +25 °C)
0.114 dB (operating temperature range +15 °C to +35 °C)
0.183 dB (operating temperature range 0 °C to +50 °C)
>3 GHz to 6 GHz 0.105 dB (operating temperature range +20 °C to +25 °C)
0.125 dB (operating temperature range +15 °C to +35 °C)
0.190 dB (operating temperature range 0 °C to +50 °C)
Uncertainty for relative power measurements
between any two power levels
RF input attenuation = 0 dB
–60 dBm to –20 dBm 0.020 dB
RF input attenuation = 30 dB
–30 dBm to +10 dBm 0.020 dB

Available options

General analysis
Product
Descrizione
R&S®NRQ6-K1

Order Number 1421.4705.02

Descrizione

I/Q data interface

R&S®NRQ6-K2

Order Number 1421.4740.02

Descrizione

Power servoing with SGT100A

R&S®NRQ6-K3

Order Number 1421.4770.02

Descrizione

Phase coherent measurements

Cables
Product
Descrizione
R&S®NRP-ZKU

Order Number 1419.0658.02

Descrizione

USB-A interface cable, length: 0.75 m

R&S®NRP-ZKU

Order Number 1419.0658.03

Descrizione

USB-A interface cable, length: 1.5 m

R&S®NRP-ZKU

Order Number 1419.0658.04

Descrizione

USB-A interface cable, length: 3 m

R&S®NRP-ZKU

Order Number 1419.0658.05

Descrizione

USB-A interface cable, length: 5 m

R&S®NRP-ZK6

Order Number 1419.0664.02

Descrizione

6-pole interface cable, length: 1.5 m

R&S®NRP-ZK6

Order Number 1419.0664.03

Descrizione

6-pole interface cable, length: 3 m

R&S®NRP-ZK6

Order Number 1419.0664.04

Descrizione

6-pole interface cable, length: 5 m

Documentation
Product
Descrizione
R&S®DCV-1

Order Number 0240.2187.06

Descrizione

Documentation of calibration values

R&S®DCV-ZP

Order Number 1173.6506.02

Descrizione

Printout of DCV

R&S®ACANRQ6

Order Number 3598.1427.03

Descrizione

R&S®Accredited calibration

Related videos

Funzionamento dei sensori di potenza selettivi in frequenza

Questo video spiega come funzionano i sensori di potenza RF selettivi in frequenza o basati su ricevitore e come differiscono dai tradizionali sensori termici o a diodi.

mag 18, 2020

Utilizzo di R&S®NRQ6

Questo video fornisce un’introduzione al sensore di potenza selettivo in frequenza R&S®NRQ6 e spiega come configurarlo per effettuare diversi tipi di misure molto comuni. Alcune esempi sono le misure di tracciamento e ACLR. Viene descritta anche l’impostazione per il collegamento e l'alimentazione tramite switch PoE.

mag 18, 2020

Sensore di potenza selettivo in frequenza R&S®NRQ6

Il sensore R&S®NRQ6 è basato sulla tecnologia del ricevitore e può eseguire misure di potenza con limitazione della banda fino a –130 dBm.

set 30, 2019

Request information

Do you have questions or need additional information? Simply fill out this form and we will get right back to you.

Autorizzazione al marketing

La tua richiesta è stata ricevuta. Ti ricontatteremo a breve.
An error is occurred, please try it again later.
Informazioni generali e legali

Manufacturer's recommended retail price (MSRP). The price shown does not include VAT. Prices and offers are only intended for entrepreneurs and not for private end consumers.

You may use the electronic signature via DocuSign to submit your information to enroll with the Rohde & Schwarz Customer Delegated Administration program. DocuSign processes the information provided according to their . The minimum system requirements for using the DocuSign system may change over time. The current system requirements are found

Termini e condizione del Concorso 10 anni di oscilloscopi Rohde & Schwarz

1. Il concorso a premi “10 anni di oscilloscopi Rohde & Schwarz” (di seguito il “Concorso”) è organizzato da Rohde & Schwarz GmbH & Co. KG, Mühldorfstraße 15, 81671 Monaco di Baviera, Germania, Tel. +49 89 41 29 0 (di seguito “R&S).

2. Tutti i partecipanti possono registrarsi al concorso dal 1 gennaio 2020 al 31 dicembre 2020 comunicando il loro nome, azienda e indirizzo e-mail lavorativo.

3. La partecipazione al concorso è gratuita e non è legata all’acquisto di alcun bene o servizio.

4. Il concorso è aperto alle sole persone giuridiche e solo le persone giuridiche potranno vincere i premi. Non è ammessa la partecipazione delle persone fisiche col proprio nome e account, ma un rappresentante di una persona giuridica può compilare il modulo di partecipazione in nome e per conto della persona giuridica.

5. Il premio è costituito da un oscilloscopio R&S®RTB2000 tra i 10 messi in palio nel periodo dal 1 gennaio 2020 al 31 dicembre 2020:

Premio: 1 oscilloscopio digitale R&S®RTB2000

6. L’estrazione avrà luogo nella sede di Rohde & Schwarz di Muehldorstrasse 15, 81671 Monaco di Baviera. Il vincitore di un premio sarà informato via e-mail entro cinque (5) giorni lavorativi.

7. Il rappresentante autorizzato dalla persona giuridica dovrà informare Rohde & Schwarz della volontà di accettare il premio. In caso di mancata accettazione o di mancata risposta entro due (2) settimane, verrà estratto un nuovo vincitore. Se non si potrà identificare un vincitore entro quattro (4) settimane, il concorso avrà termine e il premio non verrà assegnato.

8. I dipendenti di R&S, i membri delle loro famiglie e le persone coinvolte nel processo di estrazione e i membri delle loro famiglie sono esclusi dalla partecipazione.

9. Non è previsto alcun equivalente in denaro o permuta del premio. I premi non son trasferibili. Tutte le eventuali tasse, imposte, tributi o altri addebiti dovuti nel paese di residenza saranno a carico del partecipante al concorso.

10. I dati personali verranno trattati al solo scopo dell’estrazione del premio e cancellati dopo quattro (4) settimane dall’estrazione, salvo diverso accordo.

11. Ogni partecipante che non rispetta quanto indicato in questi Termini & Condizioni potrà essere squalificato da R&S da questo Concorso. In tali casi, i premi potranno anche essere ritirati retrospettivamente. Qualora un premio venga ritirato retrospettivamente a causa del non rispetto di questi Termini & Condizioni, dovrà essere reso dal vincitore a sue spese, inviandolo all’indirizzo di R&S indicato al punto 1, dopodiché verrà determinato in nuovo vincitore.

12. I partecipanti non potranno richiedere i premi di questo concorso e non è ammesso alcun ricorso legale a questo proposito.

13. Il concorso ed ogni altro legame contrattuale di conseguenza derivante tra R&S e il rispettivo partecipante sarà regolato della legge tedesca, senza possibilità di ricorso in caso di conflitto tra legislazioni. Il tribunale di Monaco di Baviera avrà giurisdizione esclusiva in caso di ogni disputa diretta o indiretta derivante dalla partecipazione a questo Concorso.

* “fast delivery” inside 7 working days applies to the Rohde & Schwarz in-house procedures from order processing through to available ex-factory to ship.