Looks like you're from the United States. Right now, you are on our site for Italy.

Switch to the United States
Rohde & Schwarz Knowledge+

Login or register to gain full access to the Knowledge+ platform!

I want to create an account

Register
or

I already have an account

Login
background
RS-Logo RS-Logo Mini
Scegli un indirizzo
Customer portal
Back
Aerospazio e Difesa
Back Panoramica Aerospazio e Difesa
Aeronautica
Forze terrestri
Marina
Sicurezza e crittografia
Spazio
Multidominio
Partner industriali
Contrasto dei droni
Back Panoramica Contrasto dei droni Forze dell'ordine Sistemi di contrasto ai velivoli senza pilota per attività militari Sistemi di contrasto ai velivoli senza pilota per gestori di infrastrutture critiche
Infrastrutture critiche
Back Panoramica Infrastrutture critiche Controllo del traffico aereo civile Indagini sulle reti cellulari Monitoraggio dello spettro
Radiodiffusione segnali broadcast
Regolamentazione dello spettro Reti e cybersecurity Screening di sicurezza Test navigazione aerea
Test reti mobili
Reti e Cybersecurity
Back Panoramica Reti e Cybersecurity Cybersecurity per aerospazio e difesa Cybersecurity per il settore finanziario R&S®ComSec Reti sicure e cybersecurity per autorità pubbliche Reti sicure per attività commerciali Reti sicure per la sanità
Ricerca e formazione
Back Panoramica Ricerca e formazione Accelerazione di particelle Caratterizzazione materiali Ricerca 6G Ricerca su antenne Soluzioni per laboratori di apprendimento Tecnologia quantistica
Sicurezza
Back Panoramica Sicurezza Reti e cybersecurity
Screening di sicurezza
Sicurezza pubblica
Test Automotive
Back Panoramica Test Automotive
Connettività e infotainment per autoveicoli
Radar automobilistici
Test Automotive EMC e dell'antenna sull’intero veicolo
Test dei componenti della propulsione elettrica
Test di reti intraveicolari e centraline elettroniche
Test comunicazioni wireless
Back Panoramica Test comunicazioni wireless Test EMC e certificazioni obbligatorie
Standard wireless
Test dispositivi mobili
Test infrastrutture per reti mobili
Test IoT / M2M
Test elettronica
Back Panoramica Test elettronica Test per elettronica di consumo
Componenti RF e a microonde
Test dell'elettronica di potenza
Test delle interfacce digitali ad alta velocità
Test di progetti digitali
Test dispositivi medicali
Test EMC
Test satelliti
Back Panoramica Test satelliti Test e utilizzo di stazioni di terra satellitari Test payload e bus satellitari Test satelliti in orbita Test satelliti NTN 5G Test terminali utente satellitari
Back
Misura e collaudo
Back Panoramica Misura e collaudo
Alimentatori e unità di alimentazione e misura
Amplificatori
Analizzatori
Apparecchiature di test EMC
Componenti di sistema
Generatori di segnali
Misuratori di potenza RF e a microonde
Oscilloscopi
Scanner per controllo qualità e ispezione Sistemi di test per antenne e camere di prova OTA
Strumenti di misura R&S®ESSENTIALS
Test reti mobili
Tester di radar automobilistici
Tester e sistemi per dispositivi wireless
Broadcast e Media
Back Panoramica Broadcast e Media
Distribuzione segnali broadcast
Tecnologie media
Aerospazio | Difesa | Sicurezza
Back Panoramica Aerospazio | Difesa | Sicurezza
Comunicazioni sicure
Radiomonitoraggio
Scanner di sicurezza
Sicurezza informatica
Back Panoramica Sicurezza informatica Browser web sicuri Sicurezza degli endpoint Sistemi di gestione Unità di crittografia di rete
Back
I servizi di assistenza
Back Panoramica I servizi di assistenza
Contratto di manutenzione e assistenza tecnica
Service coverages Servizi di riparazione Servizio di taratura
Supporto
Back Panoramica Supporto Accademia delle Misure Biblioteca risorse Download R&S®Instrument Manager R&S License Manager Ricerca sedi commerciali e di assistenza
My Rohde & Schwarz Richiesta di assistenza e supporto
Back Knowledge+ Eventi Download Video Webinars Accademia delle Misure
Fondamenti di tecnologia
Back Panoramica Fondamenti di tecnologia Antennas for mobile and stationary use Hopper signals Metodi di analisi dei segnali Tecniche di radiogoniometria Utilizzo dei ricevitori di monitoraggio
Back
Informazioni su Rohde & Schwarz
Back Panoramica Informazioni su Rohde & Schwarz Compliance Electronic Manufacturing Services Elevata integrazione verticale Our history
Sostenibilità
Rohde & Schwarz Italia
Notizie & media
Back Panoramica Notizie & media Contatti stampa e media NEWS Magazine Sala stampa
R&S Magazine
Back Panoramica R&S Magazine Shaping the future of connectivity Tecnologia quantistica Il Wi-Fi su Marte Dalla comprensione all'azione GPS backup Intelligenza artificiale Infrastrutture critiche Una tradizione di innovazione
Back Panoramica Offerte di lavoro Professionisti Studenti universitari Studenti delle scuole superiori Culture Eventi Contatti

Ricerca documenti e articoli

Gli articoli e documenti di Rohde & Schwarz offrono un'ampia varietà di materiale informativo.

1229 Risultati

Filtri
Data
  • Rilevanza
  • Data
Back
Risultati filtrati
Prodotti
Documentazione tecnica
Firmware e software
Informazioni sul prodotto
Lingua

Per ulteriori informazioni sulle nostre soluzioni, visitate il nostro sito Web.

Cercate nel nostro sito (3639)
Filtri applicati
  • Italian
  • English
  • Applicazioni
Annulla filtri
Harmonics and flicker compliance testing in line with IEC/EN 61000-3-2 and IEC/EN 61000-3-3

Modern electronics often generates current and voltage distortions that interfere with the 50 Hz/60 Hz mains. Without intervention, these distortions degrade power quality and can compromise the stability of the electrical network. The LMG600 power analyzer series provides a turnkey compliance test solution for harmonic current emissions and voltage flicker.

English - 3 nov 2026

Measurement Accuracy Verification Tool for R&S® HMC8012 AND UDS

The R&S®HMC8012, R&S®UDS500 and R&S®UDS600 digital multimeters support a wide range of electrical measurement functions. The permissible measurement error depends on the selected function and measurement range, the value indicated by the instrument, the signal frequency for AC measurements and the ambient temperature. Manually applying the corresponding accuracy tables can therefore be time-consuming and may lead to calculation or range-selection errors.This application note describes the Measurement Accuracy Verification Tool, a Windows desktop application developed to simplify and standardize this evaluation. The user selects the digital multimeter, measurement function, range and input unit, and then enters the reference value, the value indicated by the multimeter and the ambient temperature. For AC measurements, the applicable signal frequency and optional crest-factor contribution can also be specified.The application automatically selects the relevant instrument-specific accuracy coefficients and calculates the contributions related to the indicated value, selected range and temperature deviation. It then determines the minimum and maximum permitted values around the multimeter indication and compares the reference value with this interval. The result is displayed as a clear PASS or FAIL decision together with the calculated limits and any relevant notes or warnings.The tool can be used for manual measurement verification and calibration support. It does not communicate directly with the instruments and does not replace a calibrated reference standard or the procedures specified in the applicable instrument documentation.

English - 28 ott 2026

Precisely measure power in three-phase and multi-phase systems

Modern power electronics rely more and more on multi-phase systems. While such configurations improve performance, the higher number of phases complicates measurement and evaluation and can cause production and testing bottlenecks.

English - 13 ott 2026

Measure noise spectral density with oscilloscopes

Noise spectral density (NSD) describes the amplitude of random noise per bandwidth unit of a signal. NSD is expressed as a voltage value divided by the square root of frequency and is similar to power spectral density (PSD) which equals power of the noise per Hz. An oscilloscope with a high resolution FFT engine and flexible math channels can be used to extract NSD directly from a time domain acquisition, without a separate spectrum analyzer or a dedicated noise figure instrument.

English - 29 set 2026

Digital DC Meter Testing

The advancing expansion of DC grids, the integration of DC microgrids, and the proliferation of DC charging stations for electric vehicles - where the DC energy transferred needs to be accurately measured for accounting purposes - are all driving the demand for DC meters. As soon as the meter readings become the base for billing, the consumers have a vested interest in the DC meter's reliability and precision. It becomes a matter of trust to ensure proper verification, calibration and certification of the DC meter used (e.g. Eichrecht conformity resp. E-VDE-AR-E 2418-3-100).

English - 25 set 2026

Measuring Standby Power and Energy Efficiency

While fossil fuel reserves are constantly decreasing, the costs of energy are on the rise. Saving energy becomes increasingly important for consumers’ buying decisions. One area with a big potential for energy savings is consumer electronics operating in standby mode, since they still drain power from the grid. Whereas every single device only consumes a few watts, the overall energy consumption is considerable.For several years, power input gets optimized both in normal operation and standby. Standards like EnergyStar, EuP (Energy using Products, directive 2005/32/EU in conjunction with regulation 1275/2008) and others, as well as norms like IEC 62301:2011 or EN 50564:2011 define maximum power input along with the setup for measuring it.

English - 25 set 2026

Magnetic Characterization of Transformer Materials

Precision loss power measurement of sheet iron and ferrite cores with high signal frequency: exact, easy and in real-time! With the ZES ZIMMER – A Rohde & Schwarz Company – precision power analyzer LMG611 and other LMG models it is possible to obtain the magnetic characteristics of transformer-cores and coil materials besides a precise measurement of power loss.Those could be the peak values of the magnetic flux, the magnetic field strength and the permeability of a core which are determined at low and at high frequencies. For the quality control of magnetic materials completely wound cores can be used.Many measuring proceedings require sinusoidal field strength or flux which require expensive and complicated signal sources. Since the main point of interest is especially the saturation interval, there will be a high demand for the source in this range. It is more elegant and cheaper to use "intelligent" measuring equipment and allow arbitrary curve forms of the voltage and the current and to apply some mathematics. In doing so low-cost power sources can be used. Even the line voltage with its high harmonic distortion can be used.

English - 25 set 2026

Industry Power Performance Benchmarking of Data Centers

In today’s energy-conscious world, optimizing power efficiency in data centers has become a key focus for IT infrastructure. As the demand for data processing grows, data centers are consuming more energy, making energy efficiency in server operations a critical factor in evaluating server performance in the modern tech landscape. As a result, the need to effectively measure and benchmark power consumption to optimize server energy efficiency is more pressing than ever.

English - 25 set 2026

LMG600 Series Application: Transformers

The efficiency of power transformers is a key factor in reducing energy losses within the power distribution network, not to mention the increasing regulatory pressure from energy-consuming facilities such as data centers. Inefficiencies in power transmission result in financial losses and elevated greenhouse gas emissions, both of which must be avoided. As part of type and acceptance testing, power transformers are both specified with respect to their essential electrical parameters and subsequently tested and certified for compliance with these and other regulatory requirements. High efficiency and full conformity are the ultimate objectives. To achieve this, all relevant electrical performance parameters must be measured and analyzed with the highest precision. In addition, manufacturers are increasingly required to perform special tests tailored to advanced and application-specific requirements.

English - 25 set 2026

Advanced RF power amplifier characterization: waveform engineering and time-domain load pull

The combination of phase-calibrated wave measurements with load-pull capability is a highly practical workflow for advanced RF power amplifier characterization, waveform engineering and nonlinear model validation.

English - 22 set 2026

Next generation light electromagnetic warfare (EW): Portable, compact, mission-ready

The R&S®PR300 portable monitoring receiver sets new benchmarks with its high performance, compact design and 125 MHz real-time bandwidth for tactical spectrum awareness. By combining high speed scanning with a user friendly interface, it enhances field operations and signal detection.

English - 11 set 2026

R&S®NESTOR – GNSS interference detection

The jamming and spoofing of global navigation satellite systems (GNSS) is a growing threat that can significantly degrade GNSS receiver performance and jeopardize systems that rely on accurate positioning, navigation and timing (PNT) data. The threats can impact critical operations in transportation, public safety, critical infrastructure and autonomous systems. GNSS interference detection (GID) with R&S®NESTOR cellular network analysis software detects GNSS jamming and spoofing in real time and provides alerts and insights. Identifying interference as it occurs helps quickly assess the situation, mitigate risks and maintain operational continuity in challenging RF environments.

English - 25 ago 2026

Accurate double pulse testing with the R&S®RT-ZISO isolated probing system

The double pulse testing (DPT) is crucial to evaluating the switching behavior for metal oxide semiconductor field effect transistors (MOSFET), insulated gate bipolar transistors (IGBT) and wide bandgap (WBG) power semiconductor devices. The slew rate of switching devices is increasing, especially on high-side power transistor where referencing switch nodes creates a fast common-mode environment. Conventional highvoltage differential probes have difficulties obtaining a good measurement with their limited common-mode rejection ratio at higher frequencies.

English - 25 ago 2026

R&S®FSWP supports external local oscillators

Increase sensitivity with external sources

English - 5 ago 2026

Automating GNSS Testing Using Python

Within this application note the use of Python programming language to automatize GNSS tests using R&S signal generators is shown. With the R&S PyCharm1 plugin there exists an easy-to-use helper application which highly simplifies the first steps to start script based GNSS testing.Several GNSS use cases of R&S vector signal generators require much repetitive set-up and configuration steps, where human errors may occur. To mitigate these errors Python scripts communicating over SCPI interface may be used to automate the procedures. On the other hand looking up the SCPI-commands one-by-one can be difficult and time-consuming. For an improved user experience JetBrains PyCharm, the RsInstrument Python Module and the R&S Instrument Control PyCharm Plugin may be used to highly simplify the script writing process.This Application Note shows how to install the necessary software, connect to an R&S generator and use the Instrument Control PyCharm Plugin to easily generate user defined Python scripts.

English - 31 lug 2026

ASA Motion Link (ASA-ML) | Transmitter compliance test and signal integrity verification - Application Brochure

English - 20 lug 2026

2 MB | PDF

How to synchronize R&S MXO 4, 5, 5C Oscilloscopes for higher channel count

This educational note describes the different methods for synchronizing two or more oscilloscopes and highlights their advantages and disadvantages. It includes a detailed user guide on how to use R&S ScopeSync to synchronize two or more oscilloscopes.

English - 15 lug 2026

Understanding Noise in EMI Receivers

This application note explains how noise sets the sensitivity and usable dynamic range of EMI receivers and how to configure measurements accordingly. It covers the essentials on noise figure and system design for noise reduction, such as the preamplifier placement. The application note explains receiver settings, that all shape the displayed noise floor, and the dynamic-range trade-offs between attenuation, preamplification and preselection. It helps understanding effects on the noise floor and their consequences for compliance EMI measurements and explains how to interpret datasheet values such as DANL. Reading it helps EMC engineers set up receivers for maximum sensitivity, avoid overestimating emissions near the limit, correctly compare instrument datasheet specifications, and distinguish emissions from instrument-generated noise floor artifacts such as spurious responses or input mismatching.

English - 14 lug 2026

EMC analysis of discontinuous disturbances (click rate)

Most modern electronically controlled appliances still switch their loads – such as heating elements and motors – with mechanical relays. Each relay opening or closing generates a short, broadband click that can exceed the disturbance voltage limits of a quasi-peak (QP) detector. Because these transients are intermittent, they are evaluated separately as discontinuous disturbances (clicks) in line with CISPR 14-1/EN 55014-1.

English - 13 lug 2026

Bridging the gap: enhancing connectivity and coverage beyond offshore wind farms

Empowering coastal surveillanceOffshore wind farms, located 10 to 20 nautical miles from shore, present significant communications challenges due to the high density of wind turbines. The turbines create interference and blind spots that hinder effective communications and surveillance at sea. Maintaining reliable communications by extending beyond line of sight (BLOS) coverage and overall communications range is paramount.By integrating VHF/UHF radios into wind turbines, operators can ensure reliable communications even in blind spots, enabling remote control from shore stations to sea and therefore improving operational efficiency.

English - 13 lug 2026

Hybrid eCall verification

End-to-end hybrid eCall module conformance testing under controlled network conditions in line with EN18052:2025

English - 6 lug 2026

Using External DC Bias Current Sources with LCR Meters R&S®LCX

Ideal inductors are assumed to have linear behavior, i.e. their properties should not depend on signal amplitudes or superimposed DC bias current. Real inductors often contain magnetic core material, in order to achieve higher inductance within an available volume. All magnetic core materials exhibit nonlinear behavior in the shape of hysteresis and saturation effects. Testing the properties of an inductor depending on test signal amplitude and DC bias current is therefore indispensable for the component characterization.With option R&S®LCX-K108, LCR meters R&S®LCX100 and R&S®LCX200 can superimpose DC bias current up to 200 mA. For higher DC bias currents, an external source is required. This external source can be connected in parallel if it has a sufficiently high impedance over the measurement frequency range.This application note explains how to connect an external DC bias current source, avoid risks and hazards, and perform corrections for optimum measurement accuracy.

English - 6 lug 2026

Phased array antenna tests for 5G and satellite applications

Multiple applications such as 5G, satellite communications or radar systems use phased array antennas for beamforming, especially in the millimeterwave (mmWave) range. The individual antenna elements typically use a common signal but with individual phase shift and level ranges. The R&S®ZNA vector network analyzer offers up to four TX paths and eight RX paths for maximum flexibility in a one-box antenna test solution. It easily addresses all interesting frequency ranges such as major 5G FR2 bands as well as Ka and V bands for satellite links.

English - 3 lug 2026

Reading Between the Levels: Measuring PAM Signals

PAM-N signaling is increasingly common across high-speed serial interfaces, from Automotive Ethernet and data center interconnects to storage and general-purpose SerDes links, wherever higher spectral efficiency is required within constrained bandwidth. However, its multi-level nature means that conventional NRZ-based measurement approaches are no longer sufficient. This application note provides a structured, measurement-driven workflow for analyzing PAM-N signals on the R&S®RTP oscilloscope, using MGBASE-T1 PAM-4 as a practical black-box transmitter example. It guides users through the complete signal integrity evaluation sequence, including differential signal setup, CDR-based eye-diagram analysis with both software-based Advanced Eye and hardware-based Live Eye, transition-specific jitter decomposition, channel embedding using S-parameter models, receiver-side equalization, and SCPI-based automation. Advanced Eye provides the stable statistical view needed for detailed eye evaluation, per-eye measurements, and level-dependent analysis, while Live Eye complements this with a real-time view of signal stability, timing variation, and transient behavior as the signal is acquired. By following the workflow, engineers can move beyond a single composite eye diagram or aggregate jitter value and identify where signal degradation originates, whether from level-dependent eye closure, transition-specific timing behavior, channel loss, or equalization effects. The document is useful both as a step-by-step guide for engineers new to PAM-N measurements and as a reference for users targeting a specific part of the analysis workflow. Although MGBASE-T1 PAM-4 is used as the working example, the measurement logic can be transferred to other PAM-N transmitter investigations by adapting the signal configuration and analysis setup to the interface under test.

English - 2 lug 2026

R&S®PR300 - Elevated spectrum monitoring for regulatory authorities

The R&S®PR300 portable monitoring receiver sets new benchmarks with its high performance, compact design and 125 MHz real-time bandwidth. By combining high-speed scanning with a user-friendly interface, it enhances field operations and signal detection. This synergy provides a seamless operational experience and a complete spectral overview, making the identification and location of complex wideband signals more efficient and accurate than ever before.

English - 24 giu 2026

R&S®PR300 - Elevated spectrum monitoring for mobile network operators

The R&S®PR300 portable monitoring receiver sets new benchmarks with its high performance, compact design and 125 MHz real-time bandwidth. By combining high-speed scanning with a user-friendly interface, it enhances field operations and signal detection. This synergy provides a seamless operational experience and a complete spectral overview, making the identification and location of complex wideband signals more efficient and accurate than ever before.

English - 24 giu 2026

DisplayPort 2.1 cable compliance testing - Application Brochure

The Rohde & Schwarz DisplayPort (DP) 2.1 cable test solutions are VESA-approved for reliable and fast device compliance testing.

English - 24 giu 2026

2 MB | PDF

USB type C and legacy connector cable compliance testing - Application Brochure

Rohde & Schwarz USB4 and USB3.2 cable test solutions are USB Implementers Forum (USB-IF) approved for reliable and fast device compliance testing.

English - 16 giu 2026

2 MB | PDF

R&S®PR300 - Elevated spectrum monitoring for intelligence agencies

The R&S®PR300 portable monitoring receiver sets new benchmarks with its high performance, compact design and 125 MHz real-time bandwidth. By combining high-speed scanning with a user-friendly interface, it enhances field operations and signal detection. This synergy provides a seamless operational experience and a complete spectral overview, making the identification and location of complex wideband signals more efficient and accurate than ever before.

English - 15 giu 2026

Method of Implementation (MOI) for DisplayPort UHBR RX Return loss measurement

The purpose of this document is to provide step-by-step guidance on how to perform VESA compliance testing on a DisplayPort UHBR Receiver device for Return Loss.Throughout this Method of Implementation (MOI), procedures will detail how to perform such VESA compliance testing using the R&S® ZNB3000 lineup of Network Analyzers.

English - 11 giu 2026

background
facebook
youtube
feed
LinkedIn
instagram
Rohde & Schwarz Italia
Rohde & Schwarz è impegnata a costruire un mondo più sicuro e connesso con le sue soluzioni all'avanguardia. Gruppo tecnologico indipendente dedito all'innovazione da oltre 90 anni, lavora con un approccio a lungo termine e sostenibile, proponendosi come partner affidabile per i suoi clienti industriali e governativi in tutto il mondo.
Indirizzo

S.p.A, Via Tiburtina 1095

00156 Roma

Italia

Contatti

+06 41598.1 ric. aut.

rsi.info@rohde-schwarz.com

© 2026 Rohde & Schwarz

  • Informazioni sui cookie
  • Note legali
  • Dichiarazione di riservatezza
  • Termini e condizioni
  • Lavoro & carriere
  • Termini di utilizzo