R&S®EDST300 TACAN/DME Station Tester

Maintenance checks and signal-in-space analysis on TACAN and DME stations

Key Facts

  • High-precision TX/RX measurements on TACAN and DME systems (in line with ICAO Annex 10, ICAO Doc. 8071, MIL‑STD‑291C and STANAG 5034)
  • All required measurements with a single instrument
  • High dynamic range (110 dB) and precise peak power measurements

Brief Description

The R&S®EDST300 TACAN/DME station tester is an analyzer designed for commissioning, testing and servicing pulsed terrestrial navigation systems.

Features & Benefits

  • Commissioning and regular maintenance checking of TACAN and DME ground stations
  • Signal-in-space analysis on TACAN and DME stations
  • User-friendly design and application-specific extras

Specifications

Frequency
Frequency range 960 MHz to 1215 MHz
Reference frequency, internal
Aging per year ≤ 1 ppm

Key Facts

  • High-precision TX/RX measurements on TACAN and DME systems (in line with ICAO Annex 10, ICAO Doc. 8071, MIL‑STD‑291C and STANAG 5034)
  • All required measurements with a single instrument
  • High dynamic range (110 dB) and precise peak power measurements
  • Precise, efficient measurement of characteristic TACAN/ DME parameters (main delay < 50 ns, bearing < 0.2°)
  • Detailed, automated time domain analysis
  • Extremely compact with internal battery

Brief Description

The R&S®EDST300 TACAN/DME station tester is an analyzer designed for commissioning, testing and servicing pulsed terrestrial navigation systems. Its wide dynamic range and compact design make the R&S®EDST300 ideal especially for wired and field measurements on TACAN and DME ground stations.

Features & Benefits

  • Commissioning and regular maintenance checking of TACAN and DME ground stations
    • Precise on-channel peak power and frequency measurements
    • Analysis of TACAN/DME spectrum
    • Detailed analysis of TACAN bursts
    • Automated pulse shape analysis
    • Detailed analysis of station identifier
    • Efficient on-channel sensitivity measurement
    • Interrogation loading test
    • Adjacent-channel measurement and decoder rejection
    • High-precision measurement of reply delay and reply delay variation
  • Signal-in-space analysis on TACAN and DME stations
    • Efficient analysis in the field
    • High dynamic range
    • Modulation and signal analysis on TACAN ground stations
    • Site environment analysis
    • Battery-operated field measurements
  • User-friendly design and application-specific extras
    • Detailed analysis in line with relevant standards
    • Compact, robust design for stationary and mobile applications
    • Remote control via LAN interface
    • Exporting measurement data via USB data logger
    • Power measurements using an external power sensor
    • Maintenance, repair and service

Specifications

Frequency range   960 MHz to 1215 MHz
Reference frequency, internal
Aging per year   = 1 ppm
TX power measurement (R&S®EDST300 analyzer)
Measurement range (peak detector) autorange mode  
  RF input 1 –80 dBm to +30 dBm
  RF input 2 –100 dBm to +10 dBm
Peak level deviation standard TACAN signal in line with MIL-STD-291C or standard DME signal in line with ICAO Annex 10, RF input 1, level range 15 dBm to 25 dBm, 95 % confidence level, +20 °C to +30 °C 0.3 dB
Transponder delay/distance measurement
Input level range RF input 1 –80 dBm to +30 dBm (nom.)
Deviation –70 dBm to +30 dBm, RF input 1, measurement time = 200 ms, PRR = 100/s 95 % confidence level = 50 ns,
= 7.5 m (nom.),
= 0.005 NM (nom.)
TACAN modulation analysis (R&S®EDST-K1 option)
Input level range RF input 1 –80 dBm to +30 dBm
Bearing
Deviation –70 dBm to +30 dBm, RF input 1,standard TACAN signal in line with STANAG 5034, modulation depth of 15 Hz and 135 Hz signals = 21 %, measurement time = 1 s < 0.2 °
Bearing acquisition time   < 3 s
Pulse shape analysis (time domain, R&S®EDST-K2 option)
Resolution bandwidth selectable 0.5 MHz, 10 MHz (nom.)
Reference level   –70 dBm to +30 dBm
Trace functions   clear/write, average, max. hold
Trigger
Trigger source   level/external/DME pulse/interrogator, MRB/ARB trigger source
Trigger delay   –500 µs to +8000 µs
Pulse shape analysis pulse 1, pulse 2 rise time, duration, decay time
Deviation   < 0.05 µs (nom.)
Pulse spacing
Deviation   < 0.05 µs
RX measurement (R&S®EDST300 generator, R&S®EDST-B2 option)
Output power   –80 dBm to +30 dBm
Output power step size   0.1 dB
Level uncertainty +20 °C to +30 °C < 1 dB, 0.5 dB (typ.)
Pulse rate default mode 5 Hz to 6000 Hz in 1 Hz steps
  ICAO compliant mode, search/track 5 Hz to 150 Hz / 5 Hz to 30 Hz in 1
Pulse counter
Frequency range   2 Hz to 1 MHz
Uncertainty   < 1 Hz (nom.)
Test antenna
Gain   11 dBi (nom.)
Front-to-back ratio   > 26 dB (nom.)
General data
Power supply
Rated voltage base unit 20 V to 28 V DC
  external power supply 100 V to 240 V AC (±10 %)
Battery operating time with R&S®EDST-B3 option (new, fully charged battery) > 2.5 h
Dimensions W × H × D 342 mm × 157 mm × 266 mm (13.46 in × 6.18 in × 10.47 in) (3/4 19", 3 HU)
Weight fully equipped (incl. R&S®EDST-B2 and R&S®EDST-B3), without external power supply 7.2 kg (15.9 lb)
ありがとうございます。

リクエストは正常に送信されました。

当社より追ってご連絡いたします。

ローデ・シュワルツ・チーム

見積りを取得する

質問を入力してください。
お名前(ファースト・ネーム)を入力してください。
質問を入力してください。
有効な電子メール・アドレスを入力してください。
会社名を入力してください。
市区町村名を入力してください。
郵便番号を入力してください。
電話番号を入力してください。

国名を入力してください。
画像に表示されている文字を入力してください。
show captcha
入力内容が正しくありません。
Do not enter data in this field
ありがとうございます。

リクエストは正常に送信されました。

当社より追ってご連絡いたします。

ローデ・シュワルツ・チーム

デモを取得する

質問を入力してください。
お名前(ファースト・ネーム)を入力してください。
質問を入力してください。
有効な電子メール・アドレスを入力してください。
会社名を入力してください。
市区町村名を入力してください。
郵便番号を入力してください。

国名を入力してください。
画像に表示されている文字を入力してください。
show captcha
入力内容が正しくありません。
Do not enter data in this field
ありがとうございます。

リクエストは正常に送信されました。

当社より追ってご連絡いたします。

ローデ・シュワルツ・チーム

お問い合わせ

質問を入力してください。
お名前(ファースト・ネーム)を入力してください。
質問を入力してください。
有効な電子メール・アドレスを入力してください。
会社名を入力してください。
市区町村名を入力してください。
郵便番号を入力してください。

国名を入力してください。
画像に表示されている文字を入力してください。
show captcha
入力内容が正しくありません。
Do not enter data in this field
International Website