Key facts

  • 2 or 3 channels with max. 188 W total output power
  • Maximum output voltage of 32V per channel
  • Maximum output power per channel: 80 W; except R&S®HMP2020 (CH1: 160W)
  • Maximum output current per channel: 5 A; except R&S®HMP2020 (CH1: 10 A)
  • Electronic fuse (OCP), adjustable maximum voltage (OVP), overtemperature protection (OTP)

開始 JPY 149,200

  • 3 year warranty

Up to three channels in a single instrument

The R&S®HMP DC Power supplies are primarily designed for industrial use. With two or three output channels and up to 10 A output current, these rugged instruments are ideal for a wide variety of applications. They offer high efficiency with low residual ripple and many protection functions.

Features & benefits

More than meets your daily needs

  • All channels galvanically isolated and floating 
  • All channels have the same voltage range 
  • All channels have overload and short-circuit protection 
  • Parallel and serial operation 
  • Constant voltage and constant current modes 
  • Tracking and link functions
  • Protection functions to safeguard instrument and DUT 
  • Modern instrument concept: small, compact and quiet
R&S®HMP 2000 Power Supply
Open Lightbox

The output channels can be configured in parallel for higher output current, or in series for higher output voltage.

Easy operation

  • Intuitive to use 
  • Color coding of operating states 
  • EasyArb function for all channels 
  • Save and recall instrument settings
R&S®HMP 2000 Power Supply
Open Lightbox

All settings and operating states are clearly visualized.

Ideal for labs and test systems

  • Tailored for use in labs and system racks 
  • Sense function for more stringent accuracy requirements
  • Connections on front and rear panels
  • Remote control of instrument functions
R&S®HMP 2000 Power Supply
Open Lightbox

利用可能なモデル

Available models

  • Model name

    R&S®HMP2020

    Order number 3629.6718.02

    Number of output channels
    2
    Max. output power
    188 W
    Output voltage per channel
    0 V to 32 V
    Output current per channel
    channel 1: 10 A, channel 2: 5 A
    Starting at
  • Model name

    R&S®HMP2030

    Order number 3629.6718.03

    Number of output channels
    3
    Max. output power
    188 W
    Output voltage per channel
    0 V to 32 V
    Output current per channel
    5 A
    Starting at
Specifications
Electrical specifications
Number of output channels   2/3
Total output power   max. 188 W
Maximum output power per channel   80 W; except R&S®HMP2020, CH1: 160 W
Output voltage per channel   0 V to 32 V
Maximum output current per channel   5 A; except R&S®HMP2020, CH1: 10 A
Voltage ripple and noise (20 Hz to 20 MHz)   < 1.5 mV (RMS) (meas.)
Current ripple and noise (20 Hz to 20 MHz)   < 1 mA (RMS) (meas.)
Load recovery time*1)   < 1 ms (meas.)
Programming/readback resolution Voltage 1 mV
  Current < 1 A: 0.1 mA (10 A CH: 0.2 mA); ≥ 1 A: 1 mA
Readback accuracy (± (% of output + offset)) Voltage < 0.05% + 5 mV
  Current < 0.1% + 2 mA
Special functions
Measurement functions   voltage, current
Protection functions   OVP, OCP, OTP
FuseLink function  
Fuse delay at power-up  
Sense function  
Sink mode  
Output sequencing  
Trigger input/output  
Arbitrary function   ● (EasyArb)
Analog/modulation interface  
Data logging  
Display and interfaces
Display   240 × 64 pixel LCD
Rear panel connections   connector block with 4 lines per channel
Remote control interfaces   standard: USB, LAN; optional: IEEE-488 (GPIB), RS-232
General data
Dimensions (W × H × D)   285 × 93 × 405 mm
Weight   7.8 kg/8.0 kg
Rack installation   R&S®HZ42 option
*1) 10% to 90% load change within a band of ± 20 mV of set voltage.

Available options

General
Product Description
Dual Interface

R&S®HO720

Order number 3594.3660.02

Description

Dual Interface (RS-232/USB)

IEEE-4888 (GPIB) Interface

R&S®HO740

Order number 3622.3194.02

Description

IEEE-488 (GPIB) Interface

General accessories
Product Description

HZ42

Order number 3622.3207.02

Description

19" Rack Adapter, 2 HU

お問い合わせ

ご質問や詳細な情報のご要望などがございましたら、こちらのフォームよりお気軽にお問い合わせください。担当者よりご連絡させていただきます。

マーケティング・パーミッション

次の手段によってローデ・シュワルツから情報を受信することを希望します。

詳細について

私は、このウェブサイトの出版物に記載されているRohde & Schwarz GmbH & Co. KGおよびRohde & Schwarzの法人および子会社が、
ここで選択した手段 (電子メールまたは郵便メール) を通じて、マーケティングおよび広告目的 (特別キャンペーンや値引きに関する情報など) で、私に連絡することに同意します。その内容は、電子計測、セキュリティ通信、モニタリングおよびネットワークテスト、放送およびメディア、そしてサイバーセキュリティ分野の製品やソリューションを含みますが、上記に限定されるものではありません。

お客様の権利

この同意表明は、件名が"Unsubscribe"の電子メールをnews@rohde-schwarz.com宛に送信することにより、いつでも取り消すことができます。これに加えて、今後の電子メール広告の購読を停止するためのリンクが、送信されるすべての電子メールに記載されています。個人データの使用と取り消し手順の詳細は、「プライバシーステートメント」に記載されています。

ありがとうございます。

ローデ・シュワルツ・チーム

エラーが発生しました。後ほど、改めてお試しください。
一般および法的情報

メーカー希望小売価格(MSRP)。表示されている価格には消費税は含まれていません。表示価格は企業向けとなっており、一般消費者を対象としていません。